首页 | 本学科首页   官方微博 | 高级检索  
     


Thermal performances comparisons of the glass evacuated tube solar collectors with shapes of absorber tube
Authors:Yong Kim  Taebeom Seo  
Affiliation:bDepartment of Mechanical Engineering, Inha University, 253, Yonghyundong, Namgu, Inchon 402-751, Korea
Abstract:The thermal performance of a glass evacuated tube solar collector is numerically and experimentally investigated. The solar collector considered in this paper consists of a two-layered glass tube and an absorber tube. Air is used as the working fluid. The length and diameter of this glass tube are 1200 and 37 mm, respectively. Four different shapes of absorber tubes are considered, and the performances of the solar collectors are studied to find the best shape of the absorber tube for the solar collector. Beam irradiation, diffuse irradiation, and shade due to adjacent tubes are taken into account for a collector model to obtain a realistic estimation. In addition, a single collector tube with only beam irradiation is studied as a simplified model, and the results of the simplified model are compared to those of the collector model to identify the difference between these two models. The performance of a solar collector is affected by the shape of the absorber, incidence angle of solar irradiation, and arrangement of collector tubes. The results obtained from the simplified model are very different from those from the collector model, which considered not only beam and diffuse irradiation but also shade due to adjacent tubes.
Keywords:Glass evacuated tube solar collector  Absorber tube  Beam irradiation  Diffuse irradiation  Shade
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号