首页 | 本学科首页   官方微博 | 高级检索  
     


The complement-activating action of modern x-ray contrast agents
Authors:IuK Napolov  EN Bolotova  NL Shimanovski?
Affiliation:Immunology Research Group, Biological Sciences, University of Manchester, UK. eric.bell@man.ac.uk
Abstract:The study conducted proved that triombrast (dose dependently) > hexabrics > Ultravist > or = melitrast = omnipac in a concentration interval of 0.03-30.0 mg iodine/ml in vitro and in a dose interval of 0.5-2.0 g iodine/kg in vivo activate the complement system (CS) according to the alternative way in the blood of "sensitive" rats. The degree of CS activation by radiopaque agents (ROA) is significantly determined mathematically by their viscosity and relation of the number of iodine atoms to the number of ions or dissolved particles, and by their hydrophilic (for nonion CS) and osmotic (for ion monomeric CS) properties.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号