首页 | 本学科首页   官方微博 | 高级检索  
     


Process development and accurate low‐cost characterization for OLED sealants by using a calcium test
Authors:Steffen Hergert  Max Linkor  Markus Korny  Norbert Fruehauf
Abstract:Abstract— A calcium measurement setup was built for testing encapsulation especially for OLED applications. This setup is able to measure both reflective and transmissive cells. For the characterization of sealants, a method to compare them with other sealing products will be described. This includes the use of spacers, a homogeneous surface energy, and the geometry of the sealant line. The effects of different geometries will be discussed. The setup was designed to achieve good accuracy at a very reasonable component cost, which will allow other facilities to replicate this setup. Therefore, the construction plan as well as the list of components can be downloaded from our website (Ref. 3).
Keywords:Encapsulation  OLED  calcium  sealant