首页 | 本学科首页   官方微博 | 高级检索  
     


Void fraction measurement by a gamma-ray densitometer under instantaneous pipe rupture
Authors:Toshikazu Yano
Affiliation:Department of Nuclear Safety Research, Japan Atomic Energy Research Institute, Tokai-mura, Naka-gun, Ibaraki-ken, Japan
Abstract:A high-response gamma-ray densitometer was developed for the measurement of void fraction caused by the flashing vaporization of high-pressure and -temperature water under an instantaneous pipe break accident of a boiling water reactor, BWR. The initial conditions of the water were 6.86 MPa in pressure and saturation temperature. In order to prove the reliability and accuracy, the calibration test by dropping the acrylic void simulators and the air injection test into the cold water filled in the pipe were conducted.The following results are obtained in the experiments: (1) the cone slit method is very useful to increase the measuring accuracy, (2) it is clearly observed that the apparent increase of the void fraction occurs after the rarefaction wave passes, (3) the first maximum of the void fraction occurs with some delay time after break. Secondly, the minimum void fraction concurs with the maximum pressure in the pressure recovering process.
Keywords:
本文献已被 ScienceDirect 等数据库收录!