摘    要:针对电子信息设备防雷接地设计新要求,通过对电子信息设备常见保护接地系统的概括介绍,提出了适合于电子信息设备接地的方法。并对电子信息设备接地的常见问题作了相应的说明与分析,指出了电子信息设备防雷接地的重要性。

关 键 词:电子信息设备  防雷  保护接地  等电位联结

Lightning Protection Grounding System of Electronic Information Equipment
XU Ruiya,ZHANG Zhiwei. Lightning Protection Grounding System of Electronic Information Equipment[J]. Low Voltage Apparatus, 2009, 0(6): 47-50
Authors:XU Ruiya  ZHANG Zhiwei
Affiliation:Nanjing College of Information Technology;Nanjing 210046;China
Abstract:Aiming at the new demands of lightning protection grounding system of electronic information equipment,through the introduction of the common protective grounding system of electronic information equipment,a suitable method of electronic information equipment grounding was put forward.The questions of various kinds of grounding system of electronic information equipment were explained and analyzed.It was pointed out the importance of the grounding system of electronic information equipment.
Keywords:electronic information equipment  lightning protection  protective grounding  equipotential bonding  