首页 | 本学科首页   官方微博 | 高级检索  
     


Percutaneous fluoroscopic screw fixation of acetabular fractures
Authors:PJ Parker  C Copeland
Affiliation:R. Adams Cowley Shock Trauma Center, Baltimore, MD 21201, USA.
Abstract:Over a 2-year period eight patients underwent percutaneous fluoroscopic fixation of their acetabular fractures. Average patient age was 43 and mean ISS was 27. Mean blood loss was less than 100 ml. There were five transverse fractures, one affecting both columns, one anterior column-posterior hemitransverse and one T-type fracture. There were two ipsilateral femoral and two ipsilateral tibial fractures. Mean follow-up was 15 months. Three broad patient groups were identified. One patient died, one was lost to follow-up, four had full range of motion of the affected hip, one had good range with Brooker II heterotopic ossification and one was wheelchair-bound with Brooker IV heterotopic ossification. The technique, which requires only cannulated screws and fluoroscopy, is described.
Keywords:
本文献已被 PubMed 等数据库收录!