Feasibility assessment of vacuum cooling of cooked pork ham with water compared to that without water and with air blast cooling
Authors:Qiaofen Cheng,&   Da-Wen Sun
Affiliation:FRCFT Group, Biosystems Engineering, University College Dublin, National University of Ireland, Earlsfort Terrace, Dublin 2, Ireland
Abstract:To optimise vacuum cooling for application in the meat industry, an improved cooling method, i.e. vacuum cooling with water (or immersion vacuum cooling), was designed to cool cooked pork ham (2.2 ± 0.2 kg). It was found that the cooling time of vacuum cooling with water was significantly shorter than that of traditional air blast cooling (P < 0.05). For the cooling loss, vacuum cooling with water was significantly lower (6.99%) than that of vacuum cooling without water (13.71%) (P < 0.05). Significant differences in physical and chemical attributes were also observed for ham processed by vacuum cooling with and without water (P < 0.05). Therefore, for a certain size of pork ham, vacuum cooling with water could be an effective method to meet safety guidelines and obtain compatible quality attributes with air blast cooling.
Keywords:Air blast cooling    cooked meat    cooling time    immersion vacuum cooling    mass loss    pork ham    quality    vacuum cooling    weight loss