我国变电站首次使用500千伏H-GIS的设计综评
引用本文:张劲松,郭芝喜. 我国变电站首次使用500千伏H-GIS的设计综评[J]. 广东输电与变电技术, 2004, 0(2): 66-70
作者姓名:张劲松  郭芝喜
作者单位:广东省电力设计研究院
摘    要:我国首次在变电站采用500千伏H-GIS;与其他配电装置型式相比,H-GIS具有很多优点,适合用于经济 较好而土地资源较少的地区。本文对横沥变电站采用的500千伏H-GIS的设计情况进行综评。

关 键 词:H-GIS配电装置  变电站设计

Summary Appraise on Design of 500kV H- GIS used in the Substations at Home First
Guangdong Electric Power Design Institute Zhang Jin Song Guo Zhi Xi. Summary Appraise on Design of 500kV H- GIS used in the Substations at Home First[J]. Guangdong Power Transmission Technology, 2004, 0(2): 66-70
Authors:Guangdong Electric Power Design Institute Zhang Jin Song Guo Zhi Xi
Affiliation:Guangdong Electric Power Design Institute Zhang Jin Song Guo Zhi Xi
Abstract:H - GIS has been used in 500kV substations at home first. Comparing with another type of switchgear, H - GIS has many advantages and is suitabLe for the area where economic condition is better and but ground - resource is scarce. In this paper the author gives a summary appraising on 500kV H - GIS used in Heng Li substation.
Keywords:H-GIS Switchgear Substation design