轧机交交变频主传动系统电流失控故障分析
引用本文:李振兴,刘相华.轧机交交变频主传动系统电流失控故障分析[J].轧钢,2010,27(1):48-50.
作者姓名:李振兴  刘相华
作者单位:东北大学轧制技术及连轧自动化国家重点实验室
基金项目:国家自然科学基金资助项目 
摘    要:针对某热带连轧机主传动出现电流失控的问题,分析了交交变频调速装置的电磁干扰因素及抗干扰措施,找到了产生误触发脉冲的干扰通道,通过改造原功率柜内的脉冲触发板,即在输出到零电流检测环节的脉冲通道中增加阻断电路,切断电磁干扰进入触发板的通道,解决了电流失控故障,提高了系统的稳定性。

关 键 词:轧机主传动  交交变频  电流失控  误触发  

Analysis of Motor Current Out-of-control in Main Drive System of Rolling Mill
LI Zhen-xing,LIU Xiang-hua.Analysis of Motor Current Out-of-control in Main Drive System of Rolling Mill[J].Steel Rolling,2010,27(1):48-50.
Authors:LI Zhen-xing  LIU Xiang-hua
Affiliation:LI Zhen-xing~(1,2),LIU Xiang-hua~1 (1.State Key Laboratory of Rolling & Automation,Northeastern University,Shenyang 110004,China,2.Beijing Shougang Automation Information Technology Co.,Ltd.,Beijing 100041,China)
Abstract:The fault of current out-of-control in main drive system of a hot strip mill with AC-AC frequency conversion was studied.It was analyzed the issues of electromagnetic interference in operation,electromagnetic interference factors of thyristor trigger link and anti-interference ability.The causes of current out-of-control and pulse interference channel were found out.The solutions were proposed which is to cut off the path of electromagnetic interference by adding an isolation circuit.After taking the measur...
Keywords:main drive system of mill  AC-AC frequency conversion  current out of control  false triggering  
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《轧钢》浏览原始摘要信息
点击此处可从《轧钢》下载全文