首页 | 本学科首页   官方微博 | 高级检索  
     


Analysis of enterococci using portable testing equipment for developing countries--variance of Azide NutriDisk medium under variable time and temperature.
Authors:S Godfrey  J Watkins  K Toop  C Francis
Affiliation:Water and Sanitation Project, UNICEF, Madhya Pradesh, India. sgodfrey@unicef.org
Abstract:This report compares the enterococci count on samples obtained with Azide NutriDisk (AND) (sterile, dehydrated culture medium) and Slanetz and Bartley (SB) medium when exposed to a variable in incubation time and temperature. Three experiments were performed to examine the recovery of enterococci on AND and SB media using membrane filtration with respect to: (a) incubation time; (b) incubation temperature; and (c) a combination of the two. Presumptive counts were observed at 37, 41, 46 and 47 degrees C and at 20, 24, 28 and 48 h. These were compared to AWWA standard method 9230 C (44 degrees C, 44 h). Samples were confirmed using Kanamycin Aesculin Azide (KAA) agar. Friedman's ANOVA and Students t-test analysis indicated higher enumeration of enterococci when grown on AND (p = 0.45) than SB (p = < 0.001) at all temperatures with a survival threshold at 47 degrees C. Significant results for AND medium were noted at 20 h (p = 0.021), 24 h (p = 0.278) and 28 h (p = 0.543). The study concluded that the accuracy of the AND medium at a greater time and temperature range provided flexibility in incubator technology making it an appropriate alternative to SB medium for monitoring drinking water using field testing kits in developing countries.
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号