首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
改进型移动床生物膜反应器处理有机废水的试验   总被引:1,自引:0,他引:1       下载免费PDF全文
改进型移动床生物膜反应器(CMCBR)是在普通移动床生物膜反应器中引入导流板,使填料在全池循环移动,消除了普通移动床生物膜反应器的死角。在CMCBR处理模拟生活污水的试验中,研究了有机物的去除效果,考察了容积负荷、水力停留时间、冲击负荷等参数对处理效果的影响。试验发现,在填料填充比例为50%(体积比),进水COD质量浓度为320~550mg/L,水力停留时间为3 h的条件下,出水COD质量浓度小于100 mg/L,达到国家污水综合排放标准的一级标准。反应器具有较强的抗冲击负荷能力,出水水质稳定。  相似文献   

2.
An expanded granular sludge bed (EGSB) reactor was adopted to incubate the sludge biogranule that could simultaneously achieve sulfate reduction and sulfide reoxidization to elemental sulfur for treating molasses distillery wastewater. The EGSB reactor was operated for 175 days at 35 °C with a pH value of 7.0, chemical oxygen demand (COD) loading rate of 4.8 kg COD/(m3 d), and sulfate loading rate of 0.384 kg SO(4)(2-)/(m3 d). The optimal operation parameters, including the oxidation reduction potential (ORP), recycling rate, and hydraulic retention time (HRT), were established to obtain stable and acceptable removal efficiencies of COD, sulfate, and higher elemental sulfur production. With an ORP of -440 mV, a recycling rate of 300%, and HRT of 15 h, the COD and sulfate removal efficiencies were 73.4 and 61.3%, respectively. The elemental sulfur production ratio reached 30.1% when the elemental sulfur concentration in the effluent was 48.1 mg/L. The performance results were also confirmed by the mass balance calculation of sulfate, sulfide, and elemental sulfur over the EGSB reactor.  相似文献   

3.
A combined process consisted of a Moving-Bed Biofilm Reactor (MBBR) and chemical coagulation was investigated for textile wastewater treatment. The pilot scale MBBR system is composed of three MBBRs (anaerobic, aerobic-1 and aerobic-2 in series), each reactor was filled with 20% (v/v) of polyurethane-activated carbon (PU-AC) carrier for biological treatment followed by chemical coagulation with FeCl2. ln the MBBR process, 85% of COD and 70% of color (influent COD = 807.5 mg/L and color = 3,400 PtCo unit) were removed using relatively low MLSS concentration and short hydraulic retention time (HRT = 44 hr). The biologically treated dyeing wastewater was subjected to chemical coagulation. After coagulation with FeCl2, 95% of COD and 97% of color were removed overall. The combined process of MBBR and chemical coagulation has promising potential for dyeing wastewater treatment.  相似文献   

4.
The effects of increasing nitrobenzene (NB) concentrations and hydraulic retention time (HRT) on the performance of anaerobic baffled reactor (ABR) and aerobic completely stirred tank reactor (CSTR) were studied. In the first step the NB concentration was increased from 30 to 700 mg/L at constant COD and flowrates. Maximum COD removal efficiencies in ABR varied between 88-92% as NB concentrations increased from 30 to 210 mg/L. After this dose, COD removal efficiency decreased to 85 and 79% at NB concentrations of 550 and 700 mg/L, respectively. Removal efficiencies of NB were nearly 100% for all NB concentrations in ABR reactor effluent. In the second step, COD and NB concentrations were kept constant while HRT decreased from 10.38 days to 1 day. As HRT decreased from 10.38 to 2.5 days the COD removal efficiencies in the anaerobic and anaerobic/aerobic reactor effluents were 92-94% and 97-98%, respectively. As HRT decreased from 2.5 days to 1 day COD removal efficiencies in the anaerobic and anaerobic/aerobic reactor effluents decreased to 83 and 95%, respectively. This study showed that HRT is a more important operation parameter than increasing NB concentration in ABR/CSTR sequential reactor system. Although ABR/CSTR system exhibited good COD and NB removal efficiencies, the lower HRTs slightly decreased the removal efficiencies compared to increasing NB concentration.  相似文献   

5.
MBBR法处理桃浦工业区废水的中试研究   总被引:9,自引:0,他引:9  
李锋  向阳  周增炎 《给水排水》2001,27(4):47-49
采用MBBR法处理桃浦工业区废水 ,同原有的SBR法相比无论在有机物的去除效果上还是对有机物的耐冲击负荷上都更优越。试验结果表明 ,当HRT为 6~ 15h时 ,MBBR法对COD的平均去除率大于 75%。  相似文献   

6.
Synthetic wastewater was treated using a novel system integrating the reversed anoxic/anaerobic/oxic (RAAO) process, a micro-electrolysis (ME) bed and complex biological media. The system showed superior chemical oxygen demand (COD), total nitrogen (TN) and total phosphorus (TP) removal rates. Performance of the system was optimised by considering the influences of three major controlling factors, namely, hydraulic retention time (HRT), organic loading rate (OLR) and mixed liquor recirculation (MLR). TP removal efficiencies were 69, 87, 87 and 83% under the HRTs of 4, 8, 12 and 16 h. In contrast, HRT had negligible effects on the COD and TN removal efficiencies. COD, TN and TP removal efficiencies from synthetic wastewater were 95, 63 and 87%, respectively, at an OLR of 1.9 g/(L·d). The concentrations of COD, TN and TP in the effluent were less than 50, 15 and 1 mg/L, respectively, at the controlled MLR range of 75-100%. In this system, organics, TN and TP were primarily removed from anoxic tank regardless of the operational conditions.  相似文献   

7.
The effect of low operating temperature and pollutant concentration on the performance of five anaerobic hybrid reactors was investigated. Stable and efficient long-term (>400 days) treatment of a cold (6-13 degrees C), volatile fatty acid (VFA)-based, wastewater was achieved at applied organic loading rates (OLRs) of 5 kg chemical oxygen demand (COD) m(-3) d(-1) with COD removal efficiencies c. 84% at 6 degrees C (sludge loading rate (SLR) 1.04-1.46 kg COD kg [VSS](-1) d(-1)). VFA-based wastewaters, containing up to 14 g pentachlorophenol (PCP) m(-3) d(-1) or 155 g toluene m(-3) d(-1) were successfully treated at applied OLRs of 5-7 kg COD m(-3) d(-1). Despite transient declines in reactor performance in response to increasing toxicant loading rates, stable operation (COD removal efficiencies > 90%) and satisfactory toxicant removal efficiencies (>88%) were demonstrated by the systems.  相似文献   

8.
The H(2)-based membrane biofilm reactor was used to remove nitrate from synthetic ion-exchange brine at NaCl concentrations from ~3 to 30 g/L. NaCl concentrations below 20 g/L did not affect the nitrate removal flux as long as potassium was available to generate osmotic tolerance for high sodium, the H(2) pressure was adequate, and membrane fouling was eliminated. Operating pHs of 7-8 and periodic citric acid washes controlled membrane fouling and enabled reactor operation for 650 days. At 30 psig H(2) and high nitrate loading rates of 15 to 80 g/m(2) d, nitrate removal fluxes ranged from 2.5 to ~6 g/m(2) d, which are the highest fluxes observed when treating 30 g/L IX brine. However, percent removals were low, and the H(2) pressure probably limited the removal flux.  相似文献   

9.
The objective of this research was to study the dechlorination of 1,2-dichloroethane (1,2-DCA) in a synthetic wastewater with lab-scale anaerobic sequencing batch (ASBR) reactors. Anaerobic sludge was used as a biocatalyst. Sodium acetate and dextrose served as the main methanogenic substrate. Experimental studies were conducted at wide-range of volumetric (0.25-1.25 g COD/L.d) and specific (0.0362-0.181 g COD/ g VSS.d) loading rates and influent wastewater CODs (500-2500 mg/L). During 266 days of reactor operation, the mixed culture degraded 1,2 dichloroethane at concentrations of up to 50 mg/L, with an HRT of 48 hrs. No chlorinated intermediates or residues were found. 1,2-DCA degradation resulted in ethene and ethane formation. Acetate was the most effective electron donor for dechlorination, although, dextrose was also effective, but to a lesser extent. The mixed culture degraded 1,2 Dichloroethane in the temperature range of 28+/-4 degrees C, with the pH range of 7.25 to 7.95. The 1,2-DCA removal rates achieved, and the safe nature of the end products, signify the anaerobic sequencing batch (ASBR) reactor technology for practical decontamination of waters containing such types of organochlorines. The COD removal efficiencies were in the range of 95 to 98% depending on volumetric and specific loading rates applied.  相似文献   

10.
The anaerobic treatability of purified terephthalic acid (PTA) wastewater in a novel, rapid mass-transfer fluidized bed reactor using brick particles as porous carrier materials was investigated. The reactor operation was stable after a short 34 day start-up period, with chemical oxygen demand (COD) removal efficiency between 65 and 75%, terephthalate (TA) removal efficiency between 60% and 70%, and system organic loading rate (OLR) increasing from 7.37 to 18.52 kg COD/m(3) d. The results demonstrate that the reactor is very efficient, and requires a low hydraulic retention time (HRT) of 8 h to remove both TA and COD from the high-concentration PTA wastewater. The system also has high resistance capacity to varied OLR.  相似文献   

11.
A laboratory-scale oxic biofilm reactor using loofah sponge as support material was carried out to study its start-up characteristics and the optimum operation parameters in removing organic matter and nitrogen from domestic wastewater. It took no more than 10 days to complete microbiological cultivation and acclimation, indicating that the natural loofah sponge was a superior support material compared with some conventional ones. The influence parameter experiments showed that the hydraulic retention time (HRT) had a significant influence on the COD and NH(3)-N removal efficiencies, the average COD and NH(3)-N removal efficiencies were 83.7 and 96.9% respectively when the temperature was 25 ± 2 °C, the influent flow rate was 0.21 L/h and the HRT was 7.5 h. The loofah sponge biofilm system had a strong tolerance to organic shock loading in the present experiment. Additionally, it was found that domestic wastewater could be preferably treated with 88.9% of COD and 98.7% of NH(3)-N removal efficiencies with the corresponding influent concentrations of 260.0 and 26.8 mg/L, respectively. The observations obtained in the present study indicated that the loofah sponge was an excellent natural support material, potentially feasible for the present system for the treatment of the decentralized domestic wastewater.  相似文献   

12.
A pilot UASB reactor coupled with an external ultrafiltration (UF) membrane was operated under three different hydraulic retention times (HRT) for domestic wastewater treatment. The aim was to assess the HRT influence on system performance and fouling. The highest concentrations of COD, total solids, extracellular polymeric substances (EPS) and soluble microbial products (SMP) in UASB effluent and permeate were found when the UASB reactor was operated under the lowest HRT studied (4 hours); although the fulfillment of Mexican Standard for wastewater reclamation was not compromised. This fact could be attributed to the higher shear stress forces inside the UASB reactor when it was operated at low HRT, which promoted the release of biopolymeric substances in its effluent. Besides, the fouling propensity in the UASB effluent was worsened with HRT reduction, by increasing the fouling rate and the specific cake resistance. Based on these results, it is recommended to avoid operating the UASB reactor at low HRTs (less than 4 hours) in order to control SMP and EPS fouling potential. The results presented also suggest that HRT reduction has a detrimental effect on performance and fouling.  相似文献   

13.
A study has been conducted to investigate the effect of loading rates on membrane fouling in a moving bed biofilm membrane reactor process for municipal wastewater treatment, especially analysing the fate of submicron colloidal particles and their influence on membrane fouling. Two operating conditions defined as low and high organic loading rates were tested where the development and fate of the particulate material was characterised analysing the particle size distributions throughout the process. Analysis of the membrane performance showed higher fouling rates for the high-rate conditions. The fraction of colloidal submicron particles was higher in the membrane reactor indicating that fouling by these particles was a dominant contribution to membrane fouling.  相似文献   

14.
One of the major challenges of anaerobic technology is its applicability for low strength wastewaters, such as sewage. The lab-scale design and performance of a novel Gradual Concentric Chambers (GCC) reactor treating low (165+/-24 mg COD/L) and medium strength (550 mg COD/L) domestic wastewaters were studied. Experimental data were collected to evaluate the influence of chemical oxygen demand (COD) concentrations in the influent and the hydraulic retention time (HRT) on the performance of the GCC reactor. Two reactors (R1 and R2), integrating anaerobic and aerobic processes, were studied at ambient (26 degrees C) and mesophilic (35 degrees C) temperature, respectively. The highest COD removal efficiency (94%) was obtained when treating medium strength wastewater at an organic loading rate (OLR) of 1.9 g COD/L.d (HRT = 4 h). The COD levels in the final effluent were around 36 mg/L. For the low strength domestic wastewater, a highest removal efficiency of 85% was observed, producing a final effluent with 22 mg COD/L. Changes in the nutrient concentration levels were followed for both reactors.  相似文献   

15.
A 2.0 L volume of EGSB reactor was operated at 20 degrees C for more than 500 days with 0.3-0.4 g COD/L of sucrose base wastewater to investigate the influence of effluent-recirculation on the process performance. At the start up period, the reactor was operated in EGSB mode with 5 m/h upflow velocity by continuous effluent recirculation. The COD loading was set to 7.2-9.6 kg COD/m(3) day with HRT of 1 hour. However, in this mode, EGSB reactor exhibited insufficient COD removal efficiency, i.e., 50-60%. Therefore, UASB mode (without recirculation, 0.7 m/h upflow velocity) was used for 30 minutes in every 40 minutes cycle to increase the COD concentration in the sludge bed. As a result, an excellent process performance was shown. The COD removal efficiency increased from 65% to 91% and the reactor could maintain a good physical property of retained sludge (sludge concentration: 33.4 g VSS/L and SVI: 25 mL/g VSS). Furthermore, retained sludge possessed sufficient level of methanogenic activity at 20 degrees C.  相似文献   

16.
Abstract Two hybrid fluidised bed reactors filled with sepiolite and granular activated carbon (GAC) were operated with short cycled aeration for removing organic matter, total nitrogen and phosphorous, respectively. Both reactors were continuously operated with synthetic and/or industrial wastewater containing 350-500 mg COD/L, 110-130 mg NKT/L, 90-100 mg NH3-N/L and 12-15 mg P/L for 8 months. The reactor filled with sepiolite, treating only synthetic wastewater, removed COD, ammonia, total nitrogen and phosphorous up to 88, 91, 55 and 80% with a hydraulic retention time (HRT) of 10 h, respectively. These efficiencies correspond to removal rates of 0.95 kgCODm(-3)d(-1) and 0.16 kg total N m(-3)d(-1).The reactor filled with GAC was operated for 4 months with synthetic wastewater and 4 months with industrial wastewater, removing 98% of COD, 96% of ammonia, and 66% of total nitrogen, with an HRT of 13.6 h. No significant phosphorous removing activity was observed in this reactor. Microbial communities growing with both reactors were followed using polymerase chain reaction (PCR) and denaturing gradient gel electrophoresis (DGGE) techniques. The microbial fingerprints, i.e. DGGE profiles, indicated that biological communities in both reactors were stable along the operational period even when the operating conditions were changed.  相似文献   

17.
This work aimed at determining the degree of depuration of a recalcitrant effluent (weak black liquor, WBL) achieved in a series treatment consisting of a first stage methanogenic fluidised bed reactor followed by a second stage aerobic, upflow reactor packed with "biocubes" of Trametes versicolor immobilised onto small cubes of holm oak wood. The mesophilic, lab scale methanogenic fluidised bed reactor contained a microbial consortium immobilised onto granular activated carbon 500 microm average size. The process removed decreasing amounts of organic matter at decreasing hydraulic retention times (HRT), eventually reaching an average of 50% at 0.5 day HRT. Colour and ligninoid removals also decreased with decreasing HRT. Although the methanogenic fluidised bed reactor provided an effective treatment for the degradable organic matter, important concentrations of recalcitrant organic matter and colour still remained in the anaerobic effluent. This anaerobic effluent was fed to the aerobic packed bed reactor. Two HRT were tested in this unit, namely 5 and 2.5 days. The reactor averaged an organic matter removal in the range of 32% COD basis, during an experimental run of 95 days. Colour and ligninoid contents were removed in high percentages (69% and 54%, respectively). There was no significant difference in reactor performance at 5- and 2.5-day HRT. There was a positive correlation between pollutant removal efficiencies and Laccase activity in crude extracts of the reactor liquor. No supplemental soluble carbohydrate was required to sustain the fungus activity and the consistent reactor performance. Overall, the two-stage treatment achieved approximately a 78% removal of the original organic matter of the WBL (COD basis) and ca. 75% of colour and ligninoid contents.  相似文献   

18.
The objective of this work was to determine the partitioning of the pollutant load in urban wastewater in order to improve the conventional sewage treatment. In addition to settling tests, physical fractionation of COD in the degritted influent of Roma-Nord sewage treatment plant was performed via sequential filtration through sieves and membrane filters of the following pore size: 150-100-50-25-1-0.2 microm, and 100 kD (about 0.02 microm). Biodegradability studies were also performed on the different size fractions. Size fractionation showed that COD in Roma-Nord sewage is predominantly associated with settleable and supracolloidal (> 1 microm) particles, each size range including about 40% of total COD. Biodegradability tests indicated that the large fraction of COD associated with supracolloidal particles, which are not removed in the primary treatment, is characterised by slow degradability. This suggests that removal of these particles prior to biological treatment may greatly improve the overall treatment scheme. Preliminary pilot plant coagulation tests with lime at pH 9 showed that lime-enhanced primary treatment may increase COD removal efficiencies from typical 30-35% up to 65-70%, by inducing almost complete removal of the COD fraction associated with supracolloidal particles.  相似文献   

19.
An anaerobic submerged membrane bioreactor (AnSMBR) on pilot-scale treating a mixture composed of municipal wastewater and glucose under mesophilic temperature conditions was operated for 206 days. The performance of the AnSMBR was evaluated at different fluxes, biomass concentrations and gas sparging velocities (GSV). GSV was used to control fouling. In addition, the AnSMBR was operated in cycles that included relaxation and backwashing phases. The increase in the transmembrane pressure (fouling rate) was measured under different operational conditions and was used to evaluate the stability of the process. The fouling rate could be controlled for a long period of time at a flux of 7 l m(-2) h(-1) with a GSV of 62 m/h and an average biomass concentration of 14.8 g TSS/L. The membrane was physically cleaned after 156 days of operation. The cleaning efficiency was almost 100% indicating that no irreversible fouling was developed inside the pores of the membrane. The COD removal efficiency was close to 90%. As in anaerobic processes, nutrients were not exposed to degradation and almost no pathogens were found in the effluent, hence the effluent could be used for irrigation in agriculture.  相似文献   

20.
The treatment of grey water in two upflow anaerobic sludge blanket (UASB) reactors, operated at different hydraulic retention times (HRTs) and temperatures, was investigated. The first reactor (UASB-A) was operated at ambient temperature (14-25 degrees C) and HRT of 20, 12 and 8 h, while the second reactor (UASB-30) was operated at controlled temperature of 30 degrees C and HRT of 16, 10 and 6 h. The two reactors were fed with grey water from 'Flintenbreite' settlement in Luebeck, Germany. When the grey water was treated in the UASB reactor at 30 degrees C, total chemical oxygen demand (CODt) removal of 52-64% was achieved at HRT between 6 and 16 h, while at lower temperature lower removal (31-41%) was obtained at HRT between 8 and 20 h. Total nitrogen and phosphorous removal in the UASB reactors were limited (22-36 and 10-24%, respectively) at all operational conditions. The results showed that at increasing temperature or decreasing HRT of the reactors, maximum specific methanogenic activity of the sludge in the reactors improved. As the UASB reactor showed a significantly higher COD removal (31-64%) than the septic tank (11-14%) even at low temperature, it is recommended to use UASB reactor instead of septic tank (the most common system) for grey water pre-treatment. Based on the achieved results and due to high peak flow factor, a HRT between 8 and 12 h can be considered the suitable HRT for the UASB reactor treating grey water at temperature 20-30 degrees C, while a HRT of 12-24 h can be applied at temperature lower than 20 degrees C.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏