首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
刘辉  李广军  朱振峰 《功能材料》2012,43(9):1118-1121
以聚乙二醇-6000为模板剂,Ni(NO3)2.6H2O为镍源,通过微波水热法合成了Ni(OH)2前驱体微球,再采用热分解法最终获得介孔氧化镍微球,并对样品XRD、SEM、TEM和N2吸-脱附等结构表征。利用涂布法以离子液体为粘合剂,制备了固定血红蛋白(Hb)的复合工作电极,并对吸附于膜内的Hb电化学行为进行了研究。结果表明采用水热-热分解法可以获得直径为2.0μm颗粒堆积介孔氧化镍微球,该氧化镍微球具有高的比表面积(234m2/g)和窄的孔径分布(3.25nm)。循环伏安实验表明,在pH值=7.0的磷酸缓冲溶液中,Hb表现出一对峰型良好的准可逆氧化还原峰,为Hb Fe(Ⅲ)/Fe(Ⅱ)电对的特征峰,对其直接电化学行为进行了研究,求出电位为-0.278V(vs Ag/AgCl),电子转移数为1.104,电荷传递系数为0.476,表观异相电子转移速率常数为0.775s-1。  相似文献   

2.
An effective myoglobin-Nafion film is prepared by introducing gold nanoparticles in through a simple procedure by ion-exchange combined with electrochemical reduction. Gold nanoparticles are highly dispersed in myoglobin-Nafion film with an average size of 2.3 +/- 0.2 nm. The electrochemical behavior of myoglobin entrapped in the film has been carefully investigated with cyclic voltammetry. The results show that the introduction of gold nanoparticles into myoglobin-Nafion film makes the direct electron transfer of myoglobin efficient. A pair of well-defined redox peaks for myoglobin heme Fe(II)/Fe(III) is observed with a formal potential of -0.150 V in 0.1 M phosphate buffer (pH 7.0). The electrochemical parameters of myoglobin in the composite film are further calculated with the results of the electron-transfer rate constant (k(s)) as 0.93 s(-1) and the charge transfer coefficient (alpha) as 0.69. The experimental results also demonstrate that the immobilized myoglobin retains its electrocatalytic activity for the reduction of hydrogen peroxide and the catalytic reduction peak of myoglobin appear in a linear relationship with H2O2 concentration in the range of 10.0-235.0 microM with correlation coefficient of 0.9970. Thus fabricated Au/Mb/Nafion electrode should give a new approach for developing redox protein or enzyme-based biosensors.  相似文献   

3.
Here, we report the electrochemical synthesis of TiO(2) nanoparticles (NPs) using the potentiostat method. Synthesized particles have been characterized by using x-ray diffraction (XRD) studies, atomic force microscopy (AFM) and scanning electron microscopy (SEM). The results revealed that the TiO(2) film produced was mainly composed of rutile and that the particles are of a size in the range of 100 ± 50?nm. TiO(2) NPs were used for the modification of a screen printed carbon electrode (SPE). The resulting TiO(2) film coated SPE was used to immobilize flavin adenine dinucleotide (FAD). The flavin enzyme firmly attached onto the metal oxide surface and this modified electrode showed promising electrocatalytic activities towards the reduction of hydrogen peroxide (H(2)O(2)) in physiological conditions. The electrochemistry of FAD confined in the oxide film was investigated. The immobilized FAD displayed a pair of redox peaks with a formal potential of -0.42?V in pH?7.0 oxygen-free phosphate buffers at a scan rate of 50?mV?s(-1). The FAD in the nanostructured TiO(2) film retained its bioactivity and exhibited excellent electrocatalytic response to the reduction of H(2)O(2), based on which a mediated biosensor for H(2)O(2) was achieved. The linear range for the determination of H(2)O(2) was from 0.15 × 10(-6) to 3.0 × 10(-3)?M with the detection limit of 0.1 × 10(-6)?M at a signal-to-noise ratio of 3. The stability and repeatability of the biosensor is also discussed.  相似文献   

4.
Direct electron transfer from boron-doped diamond electrodes to heme undecapeptide and horseradish peroxidase (HRP) was examined and evaluated for the application to H2O2 biosensors. As-grown and oxygen plasma-treated diamond electrodes on which heme peptide is adsorbed exhibited cathodic current responses to H2O2 on the basis of the direct electron transfer. In a comparative study of carbon electrodes on which heme peptide was adsorbed, an oxygen plasma-treated diamond electrode exhibited responses comparable with those of an edge-oriented pyrolytic graphite (EOPG) electrode, despite much smaller roughness. However, electron transfer to compounds I and II of HRP from the diamond electrodes was much slower than that from EOPG or glassy carbon, suggesting that the pi electrons of an sp2 carbon may play an important role in the direct electron transfer to the heme moiety of HRP. To examine the applicability of heme peptide-modified diamond electrodes to oxidase-based biosensors, anodic current responses of the oxygen plasma-treated diamond electrode to possible interfering agents, ascorbic acid and uric acid, were examined and compared with those of EOPG. Since the diamond electrode exhibited much less sensitivity to those interfering agents, the heme peptide-modified diamond electrode should be a promising H2O2 biosensor for the application to oxidase-based biosensors.  相似文献   

5.
Zhang Q  Yang S  Zhang J  Zhang L  Kang P  Li J  Xu J  Zhou H  Song XM 《Nanotechnology》2011,22(49):494010
A novel hybrid nanomaterial (GO-MWNTs) was explored based on the self-assembly of multiwall carbon nanotubes (MWNTs) and graphene oxide (GO). Compared with pristine MWNTs, such a nanocomposite could be well dispersed in aqueous solution and exhibit a negative charge. Driven by the electrostatic interaction, positively charged horseradish peroxidase (HRP) could then be immobilized onto GO-MWNTs at the surface of a glassy carbon (GC) electrode to form a HRP/GO-MWNT/GC electrode under mild conditions. TEM was used to characterize the morphology of the GO-MWNT nanocomposite. UV-vis and FTIR spectra suggested that HRP was immobilized onto the hybrid matrix without denaturation. Furthermore, the immobilized HRP showed enhanced direct electron transfer for the HRP-Fe(III)/Fe(II) redox center. Based on the direct electron transfer of the immobilized HRP, the HRP/GO-MWNT/GC electrode exhibited excellent electrocatalytic behavior to the reduction of H(2)O(2) and NaNO(2), respectively. Therefore, GO-MWNTs could provide a novel and efficient platform for the immobilization and biosensing of redox enzymes, and thus may find wide potential applications in the fabrication of biosensors, biomedical devices, and bioelectronics.  相似文献   

6.
Two-dimensional (2D) titanium carbide (MXene) nanosheets exhibited excellent conductivity,flexibility,high volumetric capacity,hydrophilic surface,thermal stability,etc.So,it has been exploited in various applications.Herein,we report synthesis of mixed phase 2D MXene as a catalytic material for simultaneous detection of important biomolecules such as ascorbic acid (AA),dopamine (DA) and uric acid (UA),Crystalline structure,surface morphology and elemental composition of mixed phase titanium carbide (Ti-C-Tx) MXene (Tx =-F,-OH,or-O) nanosheets were confirmed by X-ray diffraction (XRD),Raman spectroscopy,high-resolution transmission electron microscopy (HR-TEM),high-resolution scanning electron microscopy (HR-SEM) and Energy-dispersive X-ray spectroscopy (EDS) mapping analysis.Furthermore,Ti-C-Tx modified glassy carbon electrode (GCE) was prepared and its electrochemical properties are studied by cyclic voltammetry (CV) and differential pulse voltammetry (DPV).It was found that Ti-C-Tx modified GCE (Ti-C-Tx/GCE) showed excellent electrocatalytic activity and separated oxidation peaks of important biomolecules such as AA (at 0.01 V),DA (at 0.21 V) and UA (at 0.33 V).Also,Ti-C-Tx/GCE sensor is enabled their simultaneous detection in physiological pH from 100 to 1000 μM for AA,0.5-50 μM for DA and 0.5-4 μM & 100-1500 μM for UA.The limit ofdetection's (LOD) was estimated as 4.6 μM,0.06 μM and 0.075 μM for AA,DA and UA,respectively.Moreover,real sample analysis indicated that spiked AA,DA and UA can be determined accurately by Ti-C-Tx/GCE with the recovery ratio in the range between 100.5%-103% in human urine samples.The proposed Ti-C-Tx modified electrode exhibited good stability,selectivity and reproducibility as an electrochemical sensor for the detection ofAA,DA and UA molecules.  相似文献   

7.
Zhou Y  Zhi J  Zou Y  Zhang W  Lee ST 《Analytical chemistry》2008,80(11):4141-4146
Cytochrome c (Cyt c) was covalently immobilized on a boron-doped nanocrystalline diamond (BDND) electrode via surface functionalization with undecylenic acid methyl ester and subsequent removal of the protecting ester groups to produce a carboxyl-terminated surface. Cyt c-modified BDND electrode exhibited a pair of quasi-reversible and well-defined redox peaks with a formal potential (E(0)) of 0.061 V (vs Ag/AgCl) in 0.1 M phosphate buffer solution (pH 7.0) and a surface-controlled process with a high electron transfer constant (ks) of 5.2 +/- 0.6 s(-1). The electrochemical properties of as-deposited and Cyt c-modified boron-doped microcrystalline diamond (BDMD) electrodes were also studied for comparison. Investigation of the electrocatalytic activity of the Cyt c-modified BDND electrode toward hydrogen peroxide (H2O2) revealed a rapid amperometric response (5 s). The linear range of response to H2O2 concentration was from 1 to 450 microM, and the detection limit was 0.7 microM at a signal-to-noise ratio of 3. The stability of the Cyt c-modified BDND electrode, in comparison with that of the BDMD and glassy carbon counterpart electrodes, was also evaluated.  相似文献   

8.
This study describes the development of a novel bimetal (Fe and Cu)-grown hierarchical web of carbon micro-nanofiber-based electrode for biosensor applications, in particular to detect glucose in liquids. Carbon nanofibers (CNFs) are grown on activated carbon microfibers (ACFs) by chemical vapor deposition (CVD) using Cu and Fe as the metal catalysts. The transition metal-fiber composite is used as the working electrode of a biosensor applied to detect glucose in liquids. In such a bi-nanometal-grown multi-scale web of ACF/CNF, Cu nanoparticles adhere to the ACF-surface, whereas Fe nanoparticles used to catalyze the growth of nanofibers attach to the CNF tips. By ultrasonication, Fe nanoparticles are dislodged from the tips of the CNFs. Glucose oxidase (GOx) is subsequently immobilized on the tips by adsorption. The dispersion of Cu nanoparticles at the substrate surface results in increased conductivity, facilitating electron transfer from the glucose solution to the ACF surface during the enzymatic reaction with glucose. The prepared Cu-ACF/CNF/GOx electrode is characterized for various surface and physicochemical properties by different analytical techniques, including scanning electron microscopy (SEM), electron dispersive X-ray analysis (EDX), Fourier-transform infrared spectroscopy (FTIR), BET surface area analysis, and transmission electron microscopy (TEM). The electrochemical tests show that the prepared electrode has fast response current, electrochemical stability, and high electron transfer rate, corroborated by CV and calibration curves. The prepared transition metal-based carbon electrode in this study is cost-effective, simple to develop, and has a stable immobilization matrix for enzymes.  相似文献   

9.
A disposable reagentless hydrogen peroxide biosensor based on the direct electrochemistry of hemoglobin immobilized on a colloidal gold-modified screen-printed carbon electrode (Hb-Au-SPCE) was proposed. The electrochemical behavior of immobilized Hb at a SPCE was studied for the first time. The electrode reaction of immobilized Hb showed a surface-controlled process with an electron transfer rate constant of (0.40 /spl plusmn/ 0.02) s/sup -1/ determined in the scan rate range from 25 to 200 mV s/sup -1/. The Hb-Au-SPCE exhibited an electrocatalytic activity toward the reduction of hydrogen peroxide with a K/sub M//sup app/ value of 1.8 mM, which was allowed to be used as a disposable sensor for determination of hydrogen peroxide with a linear range from 1.0 /spl times/ 10/sup -5/ M to 3.2 /spl times/ 10/sup -4/ M, a detection limit of 5.5 /spl times/ 10/sup -6/ M at 3/spl sigma/, a high sensitivity, fast response, and good selectivity, accuracy, and reproducibility. The disposable reagentless sensor was stable, low cost, and simple to use for detection of hydrogen peroxide in real samples.  相似文献   

10.
Standard electrochemical data for high-quality, boron-doped diamond thin-film electrodes are presented. Films from two different sources were compared (NRL and USU) and both were highly conductive, hydrogen-terminated, and polycrystalline. The films are acid washed and hydrogen plasma treated prior to use to remove nondiamond carbon impurity phases and to hydrogen terminate the surface. The boron-doping level of the NRL film was estimated to be in the mid 1019 B/cm3 range, and the boron-doping level of the USU films was approximately 5 x 10(20) B/cm(-3) based on boron nuclear reaction analysis. The electrochemical response was evaluated using Fe-(CN)6(3-/4-), Ru(NH3)6(3+/2+), IrCl6(2-/3-), methyl viologen, dopamine, ascorbic acid, Fe(3+/2+), and chlorpromazine. Comparisons are made between the apparent heterogeneous electron-transfer rate constants, k0(app), observed at these high-quality diamond films and the rate constants reported in the literature for freshly activated glassy carbon. Ru(NH3)6(3+/2+), IrCl6(2-/3-), methyl viologen, and chlorpromazine all involve electron transfer that is insensitive to the diamond surface microstructure and chemistry with k0(app) in the 10(-2)-10(-1) cm/s range. The rate constants are mainly influenced by the electronic properites of the films. Fe(CN)6(3-/4-) undergoes electron transfer that is extremely sensitive to the surface chemistry with k0(app) in the range of 10(-2)-10(-1) cm/s at the hydrogen-terminated surface. An oxygen surface termination severely inhibits the rate of electron transfer. Fe(3+/2+) undergoes slow electron transfer at the hydrogen-terminated surface with k0(app) near 10(-5) cm/s. The rate of electron transfer at sp2 carbon electrodes is known to be mediated by surface carbonyl functionalities; however, this inner-sphere, catalytic pathway is absent on diamond due to the hydrogen termination. Dopamine, like other catechol and catecholamines, undergoes sluggish electron transfer with k0(app) between 10(-4) and 10(-5) cm/s. Converting the surface to an oxygen termination has little effect on k0(app). The slow kinetics may be related to weak adsorption of these analytes on the diamond surface. Ascorbic acid oxidation is very sensitive to the surface termination with the most negative Ep(ox) observed at the hydrogen-terminated surface. An oxygen surface termination shifts Ep(ox) positive by some 250 mV or more. An interfacial energy diagram is proposed to explain the electron transfer whereby the midgap density of states results primarily from the boron doping level and the lattice hydrogen. The films were additionally characterized by scanning electron microscopy and micro-Raman imaging spectroscopy. The cyclic voltammetric and kinetic data presented can serve as a benchmark for research groups evaluating the electrochemical properties of semimetallic (i.e., conductive), hydrogen-terminated, polycrystalline diamond.  相似文献   

11.
A nano carbon coating layer was prepared by the thermal evaporation of fullerene C60 on the surface of lithium metal anodes for rechargeable lithium batteries. The morphology and structure of the carbon layer was firstly investigated by Raman spectroscopy, scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The effects of the nano-carbon coating layer on the electrochemical performance of the lithium electrode were then examined by charge-discharge tests and impedance spectroscopy. Raman spectra of carbon coating layer showed two main peaks (D and G peaks), indicating the amorphous structure of the film. A honey comb-like structure of carbon film was observed by TEM photographs, providing a transport path for the transport of lithium ions at the electrode/electrolyte interface. The carbon coated lithium electrodes exhibited a higher initial coulombic efficiency (91%) and higher specific capacity retention (88%) after the 30th cycle at 0.2 C-rate between 3.4 and 4.5 V. Impedance measurements showed that the charge transfer resistance was significantly reduced after cycle tests for the carbon coated electrodes, revealing that the more stable solid electrolyte (SEI) layer was established on their surface. Based on the experimental results, it suggested that the presence of the nano-carbon coating layer might suppress the dendritic growth on the surface of lithium metal electrodes, as confirmed by the observation of SEM images after cycle tests.  相似文献   

12.
碳弧法制备碳包铁纳米颗粒的研究   总被引:2,自引:0,他引:2  
用直汉碳弧法制备碳包铁纳米颗粒,应用透射电镜(TEM)、X射线衍射分析(XRD)和穆斯堡尔谱学进行研究,结果表明,当阳极复合棒中为纯铁粉加石墨粉时,出现3种碳包铁纳米颗粒:α-Fe,渗碳体(Fe3C)和奥氏体;当阳极复合棒中为Fe2O3加石墨粉时,出现4种碳包铁纳米颗粒:α-Fe,渗碳体,奥氏体和FeO。它们的尺寸大小在5~50nm范围。  相似文献   

13.
Carbon nitride films have been synthesized in a wide range of biases from 0 to -900 V by vacuum cathodic arc method. The N content was about 12.0-22.0 at. pct. Upon increasing the biases from 0 to -100 V, the N content increased from 15.0 to 22.0 at. pct which could be attributed to the knot-on effect. While the further increasing biases led to the gradual falling of the N content to 12.0 at. pct at -900 V due to the enhancement of the sputtering effect. Below -200 V, with the increasing biases the sp2C fraction in the films decreased, as a result of vvhich the I(D)/I(G) fell in the Raman spectra and the sp peaks also showed the decreasing tendency relative to the s peaks in the VBXPS (valence band X-ray photoelectron spectroscopy). While above -200 V, the sp2C fraction increased and the films became graphitinized gradually, accompanying which the I(D)/I(G) rose from -200 V to -300 V and the Raman spectra even shovved the graphite characteristic above -300 V and the sp peaks rose again relative to the s  相似文献   

14.
A.K.M. Kafi 《Thin solid films》2007,515(12):5179-5183
Hemoglobin (Hb) was immobilized in poly-allylamine (PAA) film onto the gold electrode by layer by layer (LBL) method. The modified electrode exhibited a pair of well-defined peaks during cyclic voltammetry, which was attributed from the direct electron transfer of heme proteins. The immobilized Hb showed an excellent electrocatalytical response to the reduction of hydrogen peroxide. The sensor exhibited a fast response and high sensitivity. Through the use of optimized conditions, the linear range for H2O2 detection was from 2.5 × 10− 6 M to 5 × 10− 4 M with detection limit of 0.2 μM. The proposed biosensor showed long-lasting stability and excellent reproducibility.  相似文献   

15.
An amperometric glucose biosensor was prepared using polyaniline (PANI) and chitosan-coupled carbon nanotubes (CS-CNTs) as the signal amplifiers and glucose oxidase (GOD) as the glucose detector on a gold electrode (the Au-g-PANI-c-(CS-CNTs)-GOD biosensor). The PANI layer was prepared via oxidative graft polymerization of aniline from the gold electrode surface premodified by self-assembled monolayer of 4-aminothiophenol. CS-CNTs were covalently coupled to the PANI-modified gold substrate using glutaradehyde as a bifunctional linker. GOD was then covalently bonded to the pendant hydroxyl groups of chitosan using 1,4-carbonyldiimidazole as the bifunctional linker. The surface functionalization processes were ascertained by X-ray photoelectron spectroscopy (XPS) analyses. The field emission scanning electron microscopy (FESEM) images of the Au-g-PANI-c-(CS-CNTs) electrode revealed the formation of a three-dimensional surface network structure. The electrode could thus provide a more spatially biocompatible microenvironment to enhance the amount and biocatalytic activity of the immobilized enzyme and to better mediate the electron transfer. The resulting Au-g-PANI-c-(CS-CNTs)-GOD biosensor exhibited a linear response to glucose in the concentration range of 1-20 mM, good sensitivity (21 μA/(mM·cm(2))), good reproducibility, and retention of >80% of the initial response current after 2 months of storage.  相似文献   

16.
硬质相对冷喷涂FeAl金属间化合物涂层性能的影响   总被引:1,自引:0,他引:1  
FeAl金属间化合物具有优良的物理性能和力学性能,但其室温塑性和断裂韧性低,限制了其工程应用.利用机械合金化制备了Fe(Al)固溶体合金粉末及Al2O3,WC硬质相增强的复合合金粉末,通过冷喷涂沉积涂层并结合后热处理原位反应制备了FeAl金属间化合物涂层及其复合涂层.利用扫描电镜(SEM)、X射线衍射仪(XRD)及显微硬度仪等研究了硬质相对球磨粉末组织结构、冷喷涂FeAl金属间化合物涂层组织结构及性能的影响.结果表明.硬质相可显著加速球磨粉末内部层状结构的细化程度,喷涂态涂层具有不同于传统热喷涂涂层的层状组织结构,热处理可实现喷涂态涂层中Fe(Al)固溶体向FeAl金属间化合物的原位转变,致使层状结构消失,获得无粒子界面的FeAl金属间化合物涂层,弥散分布的硬质相可显著提高冷喷涂FeAl金属间化合物涂层的强化稳定性.  相似文献   

17.
High density gold nanoparticles (GNPs) on indium tin oxide (ITO) film coated glass have been prepared by one-step electrochemical deposition from KAu(CN)2 in phosphate buffer (pH 8.0) solution. The resulting electrode surface was characterized by scanning electron microscopy (SEM), UV-vis spectroscopy, X-ray diffraction (XRD) and electrochemical method. Experimental results revealed that the number density of the nanoparticles was increased by the negative shift of the applied potential, while the coverage of the deposited GNPs on ITO substrate surface was also increased by means of the increasing deposition cycles. The presence of GNPs with high coverage improved the electrochemical response of Fe(CN)6 (3-/4-). This high coverage GNP/ITO substrate was applied to immobilization superoxide dismutase (SOD) for fabrication of electrochemical biosensors. The direct electron transfer between enzyme and electrode was realized, and the electrochemical performance of the SOD electrode was improved with the high coverage of GNPs. The biosensor exhibited a rapid and high response to superoxide anion.  相似文献   

18.
The electrochemical properties of two commercial (Condias, Sumitomo) boron-doped diamond thin-film electrodes were compared with those of two types of boron-doped diamond thin film deposited in our laboratory (microcrystalline, nanocrystalline). Scanning electron microscopy and Raman spectroscopy were used to characterize the electrode morphology and microstructure, respectively. Cyclic voltammetry was used to study the electrochemical response, with five different redox systems serving as probes (Fe(CN)(6)(3)(-)(/4)(-), Ru(NH(3))(6)(3+/)(2+), IrCl(6)(2)(-)(/3)(-), 4-methylcatechol, Fe(3+/2+)). The response for the different systems was quite reproducibile from electrode type to type and from film to film for electrodes of the same type. For all five redox systems, the forward reaction peak current varied linearly with the scan rate(1/2) (nu), indicative of electrode reaction kinetics controlled by mass transport (semi-infinite linear diffusion) of the reactant. Apparent heterogeneous electron-transfer rate constants, k degrees (app), for all five redox systems were determined from deltaE(p)-nu experimental data, according to the method described by Nicholson (Nicholson, R. S. Anal. Chem. 1965, 37, 1351.). The rate constants were also verified through digital simulation (DigiSim 3.03) of the voltammetric i-E curves at different scan rates. Good fits between the experimental and simulated voltammograms were found for scan rates up to 50 V/s. k degrees (app) values of 0.05-0.5 cm/s were observed for Fe(CN)(6)(3)(-)(/4)(-), Ru(NH(3))(6)(3+/2+), and IrCl(6)(2)(-)(/3)(-) without any extensive electrode pretreatment (e.g., polishing). Lower k degrees (app) values of 10(-)(4)-10(-)(6) cm/s were found for 4-methylcatechol and Fe(3+/2+). The voltammetric responses for Fe(CN)(6)(3)(-)(/4)(-) and Ru(NH(3))(6)(3+/2+) were also examined at all four electrode types at two different solution pH (1.90, 7.35). Since the hydrogen-terminated diamond surfaces contain few, if any, ionizable carbon-oxygen functionalities (e.g., carboxylic acid, pK(a) approximately 4.5), the deltaE(p), i(p)(ox), and i(p)(red) values for the two systems were, for the most part, unaffected by the solution pH. This is in contrast to the typical behavior of oxygenated, sp(2) carbon electrodes, such as glassy carbon.  相似文献   

19.
Humic acid coated Fe(3)O(4) magnetic nanoparticles (Fe(3)O(4)/HA) were prepared for the removal of sulfathiazole from aqueous media. Fe(3)O(4)/HA exhibited high activity to produce hydroxyl (OH) radicals through catalytic decomposition of H(2)O(2). The degradation of sulfathiazole was strongly temperature-dependent and favored in acidic solution. The catalytic rate was increased with Fe(3)O(4)/HA dosage and H(2)O(2) concentration. When 3 g L(-1) of Fe(3)O(4)/HA and 0.39 M of H(2)O(2) were introduced to the aqueous solution, most sulfathiazole was degraded within 1h, and >90% of total organic carbon (TOC) were removed in the reaction period (6h). The major final products were identified as environmentally friendly ions or inorganic molecules (SO(4)(2-), CO(2), and N(2)). The corresponding degradation rate (k) of sulfathiazole and TOC was 0.034 and 0.0048 min(-1), respectively. However, when 3 g L(-1) of bare Fe(3)O(4) were used as catalyst, only 54% of TOC was eliminated, and SO(4)(2-) was not detected within 6h. The corresponding degradation rate for sulfathiazole and TOC was 0.01 and 0.0016 min(-1), respectively. The high catalytic ability of Fe(3)O(4)/HA may be caused by the electron transfer among the complexed Fe(II)-HA or Fe(III)-HA, leading to rapid regeneration of Fe(II) species and production of OH radicals.  相似文献   

20.
Direct electrochemistry of hemoglobin (Hb) is achieved by immobilizing Hb-chitosan on a gold colloid/3-aminopropyl triethylene silane/Prussian blue composite film-modified glassy carbon electrode. The modified electrode exhibits a pair of well defined and quasi-reversible peaks with a formal potential of 0.205 V. The immobilized Hb retains its biological activity and shows high catalytic activity to the reduction of hydrogen peroxide. Experimental conditions influencing the biosensor performances such as pH and potential are optimized and assessed. Under the optimized conditions, the catalytic currents are linear to the concentrations of H2O2 in the ranges of 2-480 μM. The detection limit is 0.1 μM (S/N = 3). The electrochemical sensor has high stability and good reproducibility. Ultraviolet visible absorption spectra and Fourier transform infrared spectroscopy show that Hb keeps almost natural structure in the composite film. Therefore, the composite film is an alternative matrix for protein immobilization and biosensor preparation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号