首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Recent studies have shown that the wastewater treatment plant (WWTP) is a significant source of perfluoroalkyl compounds (PFCs) in natural water. In this study, 10 PFCs were analyzed in influent and effluent wastewater and sludge samples in 15 municipal, 4 livestock and 3 industrial WWTPs in Korea. The observed distribution pattern of PFCs differed between the wastewater and sludge samples. Perfluorooctane sulfonate (PFOS) was dominant in the sludge samples with a concentration ranging from 3.3 to 54.1 ng/g, whereas perfluorooctanoic acid (PFOA) was dominant in wastewater and ranged from 2.3 to 615 ng/L and 3.4 to 591 ng/L in influent and effluent wastewater, respectively. Principal component analysis (PCA) results provided an explanation for this variation in PFC distribution patterns in the aqueous and sludge samples. The fates of PFCs in the WWTPs were related with the functional groups. The PFOS concentrations tended to decrease after treatment in most WWTPs, whereas PFOA increased. The different fates of PFOA and PFOS in WWTPs were attributed to the higher organic carbon-normalized distribution coefficient of perfluoroalkylsulfonate (PFASs) than that of the carboxylate analog, indicating the preference of PFASs to partition to sludge. Although industrial WWTPs contained high concentration of PFCs, they are not the main source of PFCs in Korean water environment because of their small release amount. WWTPs located in big cities discharged more PFCs, suggesting household sewage is one of the significant sources of PFCs contamination in the environment.  相似文献   

2.
Discharge of effluents from municipal wastewater treatment plants (WWTPs) is a route for the introduction of certain organic contaminants into aquatic environments. Earlier studies have reported the occurrence of perfluorochemicals in effluents from WWTPs. In this study, contamination profiles of perfluorinated compounds (PFCs), including perfluoroalkyl sulfonates (PFASs; PFOS, PFOSA, PFHxS) and perfluoroalkyl carboxylates (PFACs; PFOA, PFNA, PFDA, PFDoDA, PFUnDA), were determined in samples collected at various stages of wastewater treatment during different seasons. The two WWTPs selected for this study represent rural (Plant A, Kentucky) and urban (Plant B, Georgia) areas. PFOS was a major contaminant in samples from Plant A (8.2–990 ng/g dry wt in solid samples and 7.0–149 ng/L in aqueous samples), followed by PFOA (8.3–219 ng/g dry wt in solid samples and 22–334 ng/L in aqueous samples). PFOA was the predominant contaminant in samples from Plant B (7.0–130 ng/g dry wt in solid samples and 1–227 ng/L in aqueous samples), followed by PFOS (<2.5–77 ng/g dry wt in solid samples and 1.8–22 ng/L in aqueous samples). PFHxS, PFNA, PFDA, and PFOSA were detected in most of the samples, whereas PFUnDA and PFDoDA were detected in very few samples. Concentrations of some PFCs, particularly PFOA, were slightly higher in effluent than in influent, suggesting that biodegradation of some precursors contributes to the increase in PFOA concentrations in wastewater treatment processes. No large-magnitude seasonal variations in concentrations were found, although mass flow of PFCs was higher in winter than in summer. In general, samples from the rural plant in Kentucky contained greater concentrations of PFCs than did those from the urban plant in Georgia. Incineration of sludge reduced the PFC levels significantly. The mass flows of PFCs in these two plants were several hundreds of mg/day, comparable to flow values reported earlier.  相似文献   

3.
A 5-month monitoring program was undertaken in South Wales in the UK to determine the fate of 55 pharmaceuticals, personal care products, endocrine disruptors and illicit drugs (PPCPs) in two contrasting wastewater plants utilising two different wastewater treatment technologies: activated sludge and trickling filter beds. The impact of treated wastewater effluent on the quality of receiving waters was also assessed.PPCPs were found to be present at high loads reaching 10 kg day−1 in the raw sewage. Concentrations of PPCPs in raw sewage were found to correlate with their usage/consumption patterns in Wales and their metabolism. The efficiency of the removal of PPCPs was found to be strongly dependent on the technology implemented in the wastewater treatment plant (WWTP). In general, the WWTP utilising trickling filter beds resulted in, on average, less than 70% removal of all 55 PPCPs studied, while the WWTP utilising activated sludge treatment gave a much higher removal efficiency of over 85%. The monitoring programme revealed that treated wastewater effluents were the main contributors to PPCPs concentrations (up to 3 kg of PPCPs day−1) in the rivers studied. Bearing in mind that in the cases examined here the WWTP effluents were also major contributors to rivers' flows (dilution factor for the studied rivers did not exceed 23 times) the effect of WWTP effluent on the quality of river water is significant and cannot be underestimated.  相似文献   

4.
The fates of several macrolide, sulphonamide, and trimethoprim antibiotics contained in the raw sewage of the Tel-Aviv wastewater treatment plant (WWTP) were investigated after the sewage was treated using either a full-scale conventional activated sludge (CAS) system coupled with a subsequent ultrafiltration (UF) step or a pilot membrane bioreactor (MBR) system. Antibiotics removal in the MBR system, once it achieved stable operation, was 15-42% higher than that of the CAS system. This advantage was reduced to a maximum of 20% when a UF was added to the CAS. It was hypothesized that the contribution of membrane separation (in both systems) to antibiotics removal was due either to sorption to biomass (rather than improvement in biodegradation) or to enmeshment in the membrane biofilm (since UF membrane pores are significantly larger than the contaminant molecules). Batch experiments with MBR biomass showed a markedly high potential for sorption of the tested antibiotics onto the biomass. Moreover, methanol extraction of MBR biomass released significant amounts of sorbed antibiotics. This finding implies that more attention must be devoted to the management of excess sludge.  相似文献   

5.
为考察啤酒厂污水处理站的脱水污泥(简称啤酒污泥)用作城市污水厂接种污泥的可行性,摸索污泥的培养与驯化规律,采用连续操作、全流量同步培养和驯化方法,在处理能力为500m^2/d的UNITANK池中对啤酒污泥进行了培养和驯化。试验结果表明,啤酒污泥完全可以作为城市污水处理厂的接种污泥使用,而且培养时间短,出水水质好。曝气0.5h、厌氧搅拌1h时,活性污泥增长最快。将DO控制在2mg/L左右有利于活性污泥的增长;当DO长时间在7mg/L以上时,污泥浓度下降趋势明显。污泥浓度达到2000mg/L所需的培养驯化时间仅为5d;使出水水质达到一级B标准所需的培养时间约为6d。这种培养、驯化方法和经验可为其他城市污水处理厂的建设和运行提供参考。  相似文献   

6.
Removal of bis(2-ethylhexyl) phthalate at a sewage treatment plant   总被引:5,自引:0,他引:5  
Bis(2-ethylhexyl) phthalate (DEHP) concentrations were measured at different stages in a full-scale sewage treatment plant (STP) and mass balances were calculated. The DEHP load to treatment process coming from the sewer system and the internal load comprising returned supernatants and filtrate from sludge treatment and excess secondary sludge were at the same level. The DEHP removal efficiency from the water phase at the STP was on average 94% of sewage DEHP, the main removal process being sorption to primary and secondary sludges. On average 29% of DEHP was calculated to be removed in the biological nitrifying-denitrifying activated sludge process, which was much less than expected from laboratory biodegradation studies described in literature. Monoethylhexyl phthalate, the primary biotransformation product of DEHP, was not detected at any treatment stage. Approximately 32% of DEHP in sewage was removed during anaerobic digestion of the sludge, while 32% remained in the digested and dewatered sludge.  相似文献   

7.
Traditionally, the performance of full-scale wastewater treatment plants (WWTPs) is measured based on influent and/or effluent and waste sludge flows and concentrations. Full-scale WWTP data typically have a high variance which often contains (large) measurement errors. A good process engineering evaluation of the WWTP performance is therefore difficult. This also makes it usually difficult to evaluate effect of process changes in a plant or compare plants to each other. In this paper we used a case study of a full-scale nutrient removing WWTP. The plant normally uses presettled wastewater, as a means to increase the nutrient removal the plant was operated for a period by-passing raw wastewater (27% of the influent flow). The effect of raw wastewater addition has been evaluated by different approaches: (i) influent characteristics, (ii) design retrofit, (iii) effluent quality, (iv) removal efficiencies, (v) activated sludge characteristics, (vi) microbial activity tests and FISH analysis and, (vii) performance assessment based on mass balance evaluation. This paper demonstrates that mass balance evaluation approach helps the WWTP engineers to distinguish and quantify between different strategies, where others could not. In the studied case, by-passing raw wastewater (27% of the influent flow) directly to the biological reactor did not improve the effluent quality and the nutrient removal efficiency of the WWTP. The increase of the influent C/N and C/P ratios was associated to particulate compounds with low COD/VSS ratio and a high non-biodegradable COD fraction.  相似文献   

8.
固定化耐冷菌处理低温生活污水研究   总被引:5,自引:0,他引:5  
从城市污水厂活性污泥中筛选出高效耐冷菌,经固定化处理后被用于净化寒冷地区的生活污水。结果表明:固定化耐冷菌的最适pH范围并未发生偏移;当水力停留时间为5h时,对COD的降解率较常规的活性污泥平均提高了约33%。  相似文献   

9.
A municipal wastewater treatment plant (WWTP) receiving industrial dyeing discharge containing acid black 1 (AB1) failed to meet NH(3) and BOD(5) discharge limits, especially for NH(3) during the winter. Dyeing discharge was combined with domestic sewage in volumetric ratios reflecting the range received by the WWTP and fed to sequencing batch reactors at 22 and 7 degrees C. Analysis of the various nitrogen species revealed complete nitrification failure at 7 degrees C with more rapid nitrification failure as the dye concentration increased. Slight nitrification inhibition occurred at 22 degrees C: NH(3) removal decreased from 99.9% for the control compared to only 97.0% removal with dye addition. Dye-bearing wastewater also reduced COD removal by half at 7 degrees C and by one-fifth at 22 degrees C, and increased effluent TSS nearly three-fold at 7 degrees C. Activated sludge quality at 7 degrees C deteriorated after exposure to AB1, as indicated by excessive foaming and the presence of filamentous bacteria and by a decrease in endogenous and exogenous oxygen uptake. Decreasing AB1 loading resulted in partial activated sludge recovery. Eliminating the dye-bearing discharge to the full-scale WWTP led to improved performance bringing the WWTP into compliance with discharge limits.  相似文献   

10.
为解决太原循环经济环卫产业园内生活垃圾焚烧处理处置、餐厨垃圾处理处置及其他固废处理处置过程中产生的高浓度废水处理问题,拟新建一座污水处理厂。设计处理规模为1 200 t/d,主要包括750 t/d的焚烧厂垃圾渗滤液和450 t/d的餐厨沼液。渗滤液处理采用"气浮+调节池+内循环厌氧反应器+两级A/O-MBR"的核心工艺,餐厨沼液处理采用"气浮+调节池+两级A/O-MBR"的核心工艺。污泥处理采用"离心脱水+热干化"工艺,处理后污泥含水率≤30%,干化污泥采用密封车辆送至焚烧厂焚烧处理。试运行结果表明,出水水质稳定达到设计标准。污水处理厂总投资为1.3亿元,污水处理直接成本为23.5元/t。  相似文献   

11.
Antibiotic resistance of E. coli in sewage and sludge   总被引:6,自引:0,他引:6  
The aim of the study is the evaluation of resistance patterns of E. coli in wastewater treatment plants without an evaluation of basic antibiotic resistance mechanisms.Investigations have been done in sewage, sludge and receiving waters from three different sewage treatment plants in southern Austria. A total of 767 E. coli isolates were tested regarding their resistance to 24 different antibiotics. The highest resistance rates were found in E. coli strains of a sewage treatment plant which treats not only municipal sewage but also sewage from a hospital.Among the antimicrobial agents tested, the highest resistance rates in the penicillin group were found for Ampicillin (AM) (up to 18%) and Piperacillin (PIP) (up to 12%); in the cephalosporin group for Cefalothin (CF) (up to 35%) and Cefuroxime-Axetil (CXMAX) (up to 11%); in the group of quinolones for Nalidixic acid (NA) (up to 15%); and for Trimethoprime/Sulfamethoxazole (SXT) (up to 13%) and for Tetracycline (TE) (57%).Median values for E. coli in the inflow (crude sewage) of the plants were between 2.0 x 10(4) and 6.1 x 10(4)CFU/ml (Coli ID-agar, BioMerieux 42017) but showed a 200-fold reduction in all three plants in the effluent. Nevertheless, more than 10(2)CFU E. coli/ml reached the receiving water and thus sewage treatment processes contribute to the dissemination of resistant bacteria in the environment.  相似文献   

12.
P. Foladori  L. Bruni 《Water research》2010,44(13):3807-3818
A rapid multi-step procedure, potentially amenable to automation, was proposed for quantifying viable and active bacterial cells, estimating their biovolume using flow cytometry (FCM) and to calculate their biomass within the main stages of a wastewater treatment plant: raw wastewater, settled wastewater, activated sludge and effluent. Fluorescent staining of bacteria using SYBR-Green I + Propidium Iodide (to discriminate cell integrity or permeabilisation) and BCECF-AM (to identify enzymatic activity) was applied to count bacterial cells by FCM. A recently developed specific procedure was applied to convert Forward Angle Light Scatter measured by FCM into the corresponding bacterial biovolume. This conversion permits the calculation of the viable and active bacterial biomass in wastewater, activated sludge and effluent, expressed as Volatile Suspended Solids (VSS) or particulate Chemical Oxygen Demand (COD). Viable bacterial biomass represented only a small part of particulate COD in raw wastewater (4.8 ± 2.4%), settled wastewater (10.7 ± 3.1%), activated sludge (11.1 ± 2.1%) and effluent (3.2 ± 2.2%). Active bacterial biomass counted for a percentage of 30-47% of the viable bacterial biomass within the stages of the wastewater treatment plant.  相似文献   

13.
This paper presents a methodology based on multivariate data analysis for identifying input sources of perfluoroalkyl substances (PFASs) detected in 37 wastewater treatment plants (WWTPs) across more than 40 cities in the state of Minnesota (USA). Exploratory analysis of data points has been carried out by unsupervised pattern recognition (cluster analysis), correlation analysis, ANOVA and per capita discharges in an attempt to discriminate sources of PFASs in WWTPs. Robust cluster solutions grouped the database according to the different PFAS profiles in WWTP influent. Significantly elevated levels of perfluorohexanoic acid (PFHxA), perfluorooctanoic acid (PFOA) and/or perfluorooctane sulfonate (PFOS) in influent have been found in 18 out of 37 WWTPs (49%). A substantial increase in the concentrations of PFHxA and/or PFOA from influent to effluent was observed in 59% of the WWTPs surveyed, suggestive of high concentration inputs of precursors. The fate of one precursor (8:2 fluorotelomer alcohol) in WWTP was modeled based on fugacity analysis to understand the increasing effluent concentration. Furthermore, population-related emissions cannot wholly explain the occurrence and levels of PFASs in WWTPs. Unusually high influent levels of PFASs were observed in WWTPs located in specific industrial areas or where known contamination had taken place. Despite the restriction on the production/use of PFOA and PFOS, this paper demonstrates that wastewater from industrial activities is still a principal determinant of PFAS pollution in urban watersheds.  相似文献   

14.
Perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA) have been recognized as global environmental pollutants. Although PFOS and PFOA have been detected in tap water from Japan and several other countries, very few studies have examined the fate, especially removal, of perfluorinated compounds (PFCs) in drinking water treatment processes. In this study, we analyzed PFOS and PFOA at every stages of drinking water treatment processes in several water purification plants that employ advanced water treatment technologies. PFOS and PFOA concentrations did not vary considerably in raw water, sand filtered water, settled water, and ozonated water. Sand filtration and ozonation did not have an effect on the removal of PFOS and PFOA in drinking water. PFOS and PFOA were removed effectively by activated carbon that had been used for less than one year. However, activated carbon that had been used for a longer period of time (>1 year) was not effective in removing PFOS and PFOA from water. Variations in the removal ratios of PFOS and PFOA by activated carbon were found between summer and winter months.  相似文献   

15.
W.J. Beer  D.F. Gibbs   《Water research》1975,9(12):1047-1050
A treatment plant designed for domestic sewage, even when working at over 95% efficiency was found to be incapable of producing an effluent of Royal Commission quality when used to treat piggery waste, the reason for this being that at dilutions normally encountered the BOD5 level of this material is more than 10 times that of domestic sewage. A method is presented in which ferric chloride is used as the flocculating agent and hydrated lime as a floc conditioner, as a tertiary treatment for the effluent from an activated sludge plant treating waste from a pig breeding and fattening unit. The rapid settling property of the conditioned floc enables separation by simple hydraulic means in 4–6 h, producing a clear effluent to Royal Commission standards for BOD5 and suspended solids and which is almost phosphorus free. Analytical data at various stages is given.  相似文献   

16.
The importance of faecal indicator organism (FIO) fluxes within drainage basins is increasing as the European Union (EU) Water Framework Directive and the United States Clean Water Act place requirements on regulators to manage point and diffuse sources of microbial pollution causing non-compliance (EU) or impairment (US) of receiving waters. Central to this management task is knowledge of the likely FIO concentrations in raw sewage and treated effluents, but few empirical data have been published in the peer-reviewed literature. Accordingly, this paper presents results for 1933 samples from 162 different sewage discharge sites in the UK and Jersey, which encompass 12 types of sewage-related discharge, representative of untreated sewage and primary-, secondary- and tertiary-treated effluents. Geometric means (GMs) and 95% confidence intervals (CIs) have been used to characterise base- and high-flow FIO concentrations. The data sets and sub-sets are mostly quite large (n 40) and may therefore be applied with some confidence to comparable discharge sites in similar geographical regions. Very marked, statistically significant reductions in GM FIO concentrations result from secondary and tertiary treatment, and there are statistically significant differences between some secondary and some tertiary treatments. Flow conditions are also shown to be important: untreated sewage and effluent from primary treatment plant have lower concentrations at high flow, due to dilution within combined sewerage systems, whereas some treated effluents (e.g. from activated sludge plant) have higher concentrations at high flow because of the shorter residence time within the plant. Under base-flow conditions, secondary treatments result in estimated GM FIO reductions of 95.22-99.29% (cf. primary-treated effluent). Corresponding figures for tertiary treatment plants (cf. secondary-treated effluent) are 93.24-96.59% for reedbed/grass plots and 99.71-99.92% for UV disinfection. Results suggest that secondary and tertiary treatment plants are less effective under high-flow conditions, but further high-flow sampling is required to confirm this.  相似文献   

17.
临沂大学污水处理厂采用循环式活性污泥法(CAST)处理校内及学校附近居民小区污水,用机械浓缩脱水一体化设备处理剩余污泥,其主体构筑物CAST生物池为鼓风微孔曝气式,出水达到了《城镇污水处理厂污染物排放标准》(GB18918—2002)的一级A标准。该污水处理厂是一座规模较大的全地下式污水处理厂,工艺先进、构筑物及设备选型合理、自动化程度高。  相似文献   

18.
陈广 《山西建筑》2014,(20):151-152
研究了上海某A/B/C活性污泥工艺污水处理厂出水SS偏高的问题,对影响出水SS的主要影响因素进行了综合分析,并提出了工艺调整措施,在实际运行中取得了较好的效果。  相似文献   

19.
循环式活性污泥法(CAST)的应用及其发展   总被引:52,自引:9,他引:52  
概括地介绍了循环式活性污泥法的主要发展及其应用,对该法在一些大型污水处理厂的具体应用也作了简单的说明。CAST系统将可变容积活性污泥法过程与生物选择器原理有机地结合在一起使其有别于传统的SBRTA工艺。  相似文献   

20.
采用气浮-厌氧滤池(AF)-CASS工艺处理植物油废水。通过清污分流,先将高浓度精炼废水进行隔油-气浮预处理,去除废水中大部分油、皂后再与低浓度浸出废水及生活污水混合进行后续处理,出水水质达到《污水综合排放标准》(GB8978-1996)一级标准。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号