首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
To determine the application limits of green fluorescent protein (GFP) as a reporter gene or protein tag, we expressed GFP by itself and with fusion protein partners, and used three different imaging methods to identify GFP fluorescence. In conventional epifluorescence photomicroscopy, GFP expressed in cells could be distinguished as a bright green signal over a yellow-green autofluorescence background. In quantitative fluorescence microscopy, however, the GFP signal is contaminated by cellular autofluorescence. Improved separation of GFP signal from HeLa cell autofluorescence was achieved by the combination of confocal scanning laser microscopy using 488-nm excitation, a rapid cut-on dichroic mirror and a narrow-bandpass emission filter. Two-photon excitation of GFP fluorescence at the equivalent of ? 390 nm provided better absorption than did 488-nm excitation. This resulted in increased signal/background but also generated a different autofluorescence pattern and appeared to increase GFP photobleaching. Fluorescence spectra similar to those of GFP alone were observed when GFP was expressed as a fusion protein either with glutathione-S-transferase (GST) or with glucokinase. Furthermore, purified GST?GFP fusion protein displayed an extinction coefficient and quantum yield consistent with values previously reported for GFP alone. In HeLa cells, the cytoplasmic GFP concentration must be greater than ? 1 μM to allow quantifiable discrimination over autofluorescence. However, lower expression levels may be detectable if GFP is targeted to discrete subcellular compartments, such as the plasma membrane, organelles or nucleus.  相似文献   

2.
We used spectrally resolved fluorescence lifetime imaging (SLIM) to investigate the mitochondria staining dye rhodamine 123 and binding of DAPI to RNA and DNA in cells. Moreover, different components of the photosensitizer Photofrin were resolved in cell cultures by SLIM. To record lifetime images (tau-mapping) with spectral resolution we used a laser scanning microscope equipped with a spectrograph, a 16 channel multianode PMT, and multidimensional time-correlated single photon counting. A Ti:Saphir laser was used for excitation or alternatively a ps diode laser. With this system the time- and spectral-resolved fluorescence characteristics of different fluorophores were investigated in cell cultures. As an example, the mitochondria staining dye rhodamine I23 could be easily distinguished from DAPI, which binds to nucleic acids. Also different binding sites of DAPI could be discriminated. This was proved by the appearance of different lifetime components within different spectral channels. Moreover, we were able to detect monomeric and aggregated forms of Photofrin in cells. Different lifetimes could be attributed to the various compounds. In addition, a detailed analysis of the autofluorescence by SLIM could explain changes of mitochondrial metabolism during Photofrin-PDT.  相似文献   

3.
Kim DU  Moon S  Song H  Kwon HS  Kim DY 《Scanning》2011,33(6):455-462
High-speed beam scanning and data acquisition in a laser scanning confocal microscope system are normally implemented with a resonant galvanometer scanner and a frame grabber. However, the nonlinear scanning speed of a resonant galvanometer can generate nonuniform photobleaching in a fluorescence sample as well as image distortion near the edges of a galvanometer scanned fluorescence image. Besides, incompatibility of signal format between a frame grabber and a point detector can lead to digitization error during data acquisition. In this article, we introduce a masked illumination scheme which can effectively decrease drawbacks in fluorescence images taken by a laser scanning confocal microscope with a resonant galvanometer and a frame grabber. We have demonstrated that the difference of photobleaching between the center and the edge of a fluorescence image can be reduced from 26 to 5% in our confocal laser scanning microscope with a square illumination mask. Another advantage of our masked illumination scheme is that the zero level or the lowest input level of an analog signal in a frame grabber can be accurately set by the dark area of a mask in our masked illumination scheme. We have experimentally demonstrated the advantages of our masked illumination method in detail.  相似文献   

4.
Two-photon excitation laser scanning fluorescence microscopy (2p-LSM) was compared with UV-excitation confocal laser scanning fluorescence microscopy (UV-CLSM) in terms of three-dimensional (3-D) calcium imaging of living cells in culture. Indo-1 was used as a calcium indicator. Since the excitation volume is more limited and excitation wavelengths are longer in 2p-LSM than in UV-CLSM, 2p-LSM exhibited several advantages over UV-CLSM: (1) a lower level of background signal by a factor of 6–17, which enhances the contrast by a factor of 6–21; (2) a lower rate of photobleaching by a factor of 2–4; (3) slightly lower phototoxicity. When 3-D images were repeatedly acquired, the calcium concentration determined by UV-CLSM depended strongly on the number of data acquisitions and the nuclear regions falsely exhibited low calcium concentrations, probably due to an interplay of different levels of photobleaching of Indo-1 and autofluorescence, while the calcium concentration evaluated by 2p-LSM was stable and homogeneous throughout the cytoplasm. The spatial resolution of 2p-LSM was worse by 10% in the focal plane and by 30% along the optical axis due to the longer excitation wavelength. This disadvantage can be overcome by the addition of a confocal pinhole (two-photon excitation confocal laser scanning fluorescence microscopy), which made the resolution similar to that in UV-CLSM. These results indicate that 2p-LSM is preferable for repeated 3-D reconstruction of calcium concentration in living cells. In UV-CLSM, 0.18-mW laser power with a 2.φ pinhole (in normalized optical coordinate) gives better signal-to-noise ratio, contrast and resolution than 0.09-mW laser power with a 4.9-φ pinhole. However, since the damage to cells and the rate of photobleaching is substantially greater under the former condition, it is not suitable for repeated acquisition of 3-D images.  相似文献   

5.
Implementation of a laser scanning confocal microscope is described, where the specimen is scanned by an array of illuminating beams, which significantly increases the velocity of object image construction. The array formation is provided by using a diffractive optical element. Scanning by the array of laser beams over the specimen is performed by galvanometric scanners with moving refractive plane-parallel plates. Owing to application of such a scanning device, the beams in the illuminating channel and the signal beams in the receiving channel pass through one motionless array of confocal diaphragms; as a result, the scanning beams in the specimen plane and the signal beams in the plane of the photodetector matrix can be used without an additional synchronized pair of scanners. The proposed confocal microscope can be applied in problems that require a fast response.  相似文献   

6.
The ability to visualize cell motility occurring deep in the context of opaque tissues will allow many currently intractable issues in developmental biology and organogenesis to be addressed. In this study, we compare two-photon excitation with laser scanning confocal and conventional digital deconvolution fluorescence microscopy, using the same optical configuration, for their ability to resolve cell shape deep in Xenopus gastrula and neurula tissues. The two-photon microscope offers better depth penetration and less autofluorescence compared to confocal and conventional deconvolution imaging. Both two-photon excitation and confocal microscopy also provide improved rejection of "out-of-focus" noise and better lateral and axial resolution than conventional digital deconvolution microscopy. Deep Xenopus cells are best resolved by applying the digital deconvolution method on the two-photon images. We have also found that the two-photon has better depth penetration without any degradation in the image quality of interior sections compared to the other two techniques. Also, we have demonstrated that the quality of the image changes at different depths for various excitation powers.  相似文献   

7.
Chinese algae fossils can provide unique information about the evolution of the early life. Thin sections of Neoproterozoic algae fossils, from Guizhou, China, were studied by confocal laser scanning microscopy, and algae fossils were fluorescenced at different wavelengths when excited by laser light of 488 nm, 476 nm, and 568 nm wavelength. When illuminated by 488 nm laser light, images of the algae fossils were sharper and better defined than when illuminated by 476 nm and 568 nm laser light. The algae fossils fluoresce at a wide range of emission wavelengths. The three-dimensional images of the fluorescent algae fossils were compared with the transmission images taken by light microscope. We found that the fluorescence image of the confocal laser scanning microscope in a single optical section could pass for the transmission image taken by a light microscope. We collected images at different sample depths and made a three-dimensional reconstruction of the algae fossils. And on the basis of the reconstruction of the three-dimensional fluorescent images, we conclude that the two algae fossils in our present study are red algae.  相似文献   

8.
针对激光共焦扫描显微镜的往复式逐行扫描成像方式带来的帧图像数据分割难的问题,在分析系统扫描方式、振镜的实际运动方式与理论运动方式差异的基础上,利用相邻两帧图像相似性大的特点,提出了一套完整的高帧速重构算法。该算法通过连续帧特征区域差分的方式实现了一维信号序列的自适应分割,即实现了对一维信号序列进行动态排列及分割成二维阵列图像数据,从而重构出多帧高精度图像。实验表明,该算法的成像误差低于1.6%,适用于成像速度高达300帧/s的激光共焦扫描显微成像。  相似文献   

9.
We report on a confocal beam scanning microscope utilizing a continuous Xe short-arc lamp operating in the visible spectrum with unprecedented radiance. Measurements of lateral and vertical resolution will be presented and compared with those of an equivalent scanning laser microscope. Resolution of the white-light microscope is equivalent to that of the scanning laser microscope. White-light microscope images positively stand out from those of the scanning laser microscope by their lack of artefacts caused by interference.  相似文献   

10.
This paper addresses the problem of intensity correction of fluorescent confocal laser scanning microscope images. Confocal laser scanning microscope images are frequently used in medicine for obtaining 3D information about specimen structures by imaging a set of 2D cross sections and performing 3D volume reconstruction afterwards. However, 2D images acquired from fluorescent confocal laser scanning microscope images demonstrate significant intensity heterogeneity, for example, due to photo‐bleaching and fluorescent attenuation in depth. We developed an intensity heterogeneity correction technique that (a) adjusts the intensity heterogeneity of 2D images, (b) preserves fine structural details and (c) enhances image contrast, by performing spatially adaptive mean‐weight filtering. Our solution is obtained by formulating an optimization problem, followed by filter design and automated selection of filtering parameters. The proposed filtering method is experimentally compared with several existing techniques by using four quality metrics: contrast, intensity heterogeneity (entropy) in a low frequency domain, intensity distortion in a high frequency domain and saturation. Based on our experiments and the four quality metrics, the developed mean‐weight filtering outperforms other intensity correction methods by at least a factor of 1.5 when applied to fluorescent confocal laser scanning microscope images.  相似文献   

11.
Reconstruction of 3D structures of specimens embedded for light or electron microscopy is usually achieved by cutting serial sections through the tissues, then assembling the images from each section to reconstruct the original structure or feature. This is both time-consuming and destructive, and may lead to areas of particular interest being missed. This paper describes a method of examining specimens which have been fixed in glutaraldehyde and embedded in epoxy resin, by utilising the autofluorescence preserved or enhanced by aldehyde fixation, and by using a confocal laser scanning microscope to section optically such specimens in the block down to a depth of about 200 μm. In this way, the accurate estimation of the depth of particular features could be used to facilitate subsequent sectioning at the light microscope or electron microscope level for more detailed studies, and 3D images of tissues/structures within the block could be easily prepared if required.  相似文献   

12.
By monitoring coenzyme autofluorescence modifications. as an indicator of cell damage. the cellular response to femtosecond near-infrared (NIR) radiation (two-photon absorption) was compared with exposure to low-power UV A radiation (one-photon absorption). Excitation radiation from a tunable Ti-sapphire laser. focused through highnumerical- aperture microscope optics. provided diffractionlimited mlcrobeams of an adjustable peak power. Laser scanning NIR microscopy was used to detect spatially the intracellular distribution of fluorescent coenzymes by fluorescence intensity imaging as well as fluorescence lifetime imaging (T-mapping). Upon the onset of UV or NIR exposure. Chinese hamster ovary cells exhibited blue/green autofluorescence witq a mean lifetime of 2·2 ns. which was attributed to NAD(P)H in mitochondria. Exposure to 365 nm radiation from a high-pressure mercury lamp (1 m W. 300 J cm-2 ) resulted in oxidative stress correlated with increased autofluorescence intensity. onset of nuclear fluorescence. and a fluorescence lifetime decrease. The cellular response to femtosecond NIR micro beams depended significantly on peak power. Peak powers above a threshold value of about 0·5kW (average power: 6mW). 0·55kW (7mW) and 0·8kW (lOmW) at 730nm. 760nm and 800nm. respectively. resulted in the onset of short-lived luminescence with higher intensity (100x) than the intracellular NAD(P)H fluorescence. This luminescence. accompanied by destruction of cellular morphology. was localized and occurred in the mitochondrial region. In contrast. beams at a power of less than 0·5 kW allowed nondestructive fluorophore detection with high spatial and temporal resolution without modification of cellular redox state or cell morphology.  相似文献   

13.
A confocal laser microscope scanner developed at our institute is described. Since an ordinary microscope is used, it is easy to view the specimen prior to scanning. Confocal imaging is obtained by laser spot illumination, and by focusing the reflected or fluorescent light from the specimen onto a pinhole aperture in front of the detector (a photomultiplier tube). Two rotating mirrors are used to scan the laser beam in a raster pattern. The scanner is controlled by a microprocessor which coordinates scanning, data display, and data transfer to a host computer equipped with an array processor. Digital images with up to 1024 × 1024 pixels and 256 grey levels can be recorded. The optical sectioning property of confocal scanning is used to record thin (~ 1 μm) sections of a specimen without the need for mechanical sectioning. By using computer-control to adjust the focus of the microscope, a stack of consecutive sections can be automatically recorded. A computer is then used to display the 3-D structure of the specimen. It is also possible to obtain quantitative information, both geometric and photometric. In addition to confocal laser scanning, it is easy to perform non-confocal laser scanning, or to use conventional microscopic illumination techniques for (non-confocal) scanning. The design has proved reliable and stable, requiring very few adjustments and realignments. Results obtained with this scanner are reported, and some limitations of the technique are discussed.  相似文献   

14.
Ribes AC  Damaskinos S  Dixon AE 《Scanning》2000,22(5):282-287
An inexpensive, high optical-quality relay lens made up of two eyepieces arranged in an afocal assembly for use in confocal scanning laser imaging is described. In the past we have used relays, within our confocal microscopes, made up of achromats with long focal lengths (> or = 10 cm), which take up large optical tracks and suffer from significant amounts of astigmatism and curvature of field. We quantify aberrations associated with achromat and eyepiece relays using CODE V optical design and analysis software. The eyepiece relay is found to be more compact, better corrected, and not significantly more expensive than its achromat counterpart. In addition to being used to interconnect two scanning mirrors optically as well as scanning mirrors with microscope objectives, it can form part of the optics in a confocal scanning laser MACROscope-Microscope system (Biomedical Photometrics, Inc., Waterloo, Ontario, Canada). Due to design constraints, the MACROscope-Microscope system cannot incorporate a conventional wide-field microscope into its structure such as is done in most commercial confocal microscopes. The eyepiece relay is used as a stand-alone, compact optical link between the scanning mirrors and the microscope objective. This consequently makes the MACROscope-Microscope system more compact and easier to commercialize.  相似文献   

15.
Recently, the laser‐scanning confocal microscope has become a routine technique and indispensable tool for cell biological studies. Previous studies indicated that reactive oxygen species (ROS) were generated in tobacco epidermal cells with confocal microscope. In the present studies, the probe 2′,7′‐dichlorof luorescein diacetate (H2DCF‐DA) was used to research the change of ROS in the guard cell of wheat stoma, and catalase (CAT) was used to demonstrate that ROS had been labeled. The laser‐scanning mode of confocal microscope was XYT, and the time interval between two sections was 1.6351 s. Sixty optical sections were acquired with the laser‐scanning confocal microscope, and CAT (60,000 U mg?1) was added after four optical sections were scanned. Furthermore, the region of interest (ROI) was circled and the fluorescence intensity of ROS was quantified with Leica Confocal Software. The quantitative data were exported and the trend chart was made with software Excell. The results indicated that ROS were produced intracellularly in stomatal guard cells, and the quantified fluorescence intensity of ROS was declined with CAT added. It is a good method to research the instantaneous change of ROS in plant cells with confocal microscope and fluorescence probe H2DCF‐DA. Microsc. Res. Tech., 2011. © 2010 Wiley‐Liss, Inc.  相似文献   

16.
We have employed field-emission secondary electron microscopy (FESEM) for morphological evaluation of freeze-fractured frozen-hydrated renal epithelial LLC-PK1 cells prepared with our simple cryogenic sandwich-fracture method that does not require any high-vacuum freeze-fracture instrumentation (Chandra et al. (1986) J. Microsc. 144 , 15–37). The cells fractured on the substrate side of the sandwich were matched one-to-one with their corresponding complementary fractured faces on the other side of the sandwich. The FESEM analysis of the frozen-hydrated cells revealed three types of fracture: (i) apical membrane fracture that produces groups of cells together on the substrate fractured at the ectoplasmic face of the plasma membrane; (ii) basal membrane fracture that produces basal plasma membrane-halves on the substrate; and (iii) cross-fracture that passes randomly through the cells. The ectoplasmic face (E-face) and protoplasmic face (P-face) of the membrane were recognized based on the density of intramembranous particles. Feasibility of fractured cells was shown for intracellular ion localization with ion microscopy, and fluorescence imaging with laser scanning confocal microscopy. Ion microscopy imaging of freeze-dried cells fractured at the apical membrane revealed well-preserved intracellular ionic composition of even the most diffusible ions (total concentrations of K+, Na+ and Ca+). Structurally damaged cells revealed lower K+ and higher Na+ and Ca+ contents than in well-preserved cells. Frozen-freeze-dried cells also allowed imaging of fluorescently labelled mitochondria with a laser scanning confocal microscope. Since these cells are prepared without washing away the nutrient medium or using any chemical pretreatment to affect their native chemical and structural makeup, the characterization of fracture faces introduces ideal sample types for chemical and morphological studies with ion and electron microscopes and other techniques such as laser scanning confocal microscopy, atomic force microscopy and near-field scanning optical microscopy.  相似文献   

17.
We have used a multiple-laser confocal microscope with lines at 325, 442, 488, 514 and 633 nm to investigate optical sectioning of botanical specimens over a wide range of wavelengths. The 442-nm line allowed efficient excitation of Chromomycin A3, with minimal background autofluorescence, to visualize GC-rich heterochromatin as an aid to chromosome identification. Sequential excitation with 442- and 488-nm light enabled ratio imaging of cytosolic pH using BCECF. The red HeNe laser penetrated deep into intact plant tissues, being less prone to scattering than shorter blue lines, and was also used to image fluorescent samples in reflection, prior to fluorescence measurements, to reduce photobleaching. Chromatic corrections are more important in confocal microscope optics than in conventional microscopy. Measured focus differences between blue, green and red wavelengths, for commonly used objectives, were up to half the optical section thickness for both our multi-laser system and a multi-line single-laser instrument. This limited high-resolution sectioning at visible wavelengths caused a loss in signal. For ultraviolet excitation the focus shift was much larger and had to be corrected by pre-focusing the illumination. With this system we have imaged DAPI-stained nuclei, callose in pollen tubes using Aniline Blue and the calcium probe Indo-1.  相似文献   

18.
在激光扫描共聚焦显微成像技术基础上引入了光谱成像技术以便区分生物组织中的不同荧光成分。采用分光棱镜对荧光进行光谱展开,在光谱谱面处设置两个可移动缝片形成出射狭缝,两个步进电机带动安装其上的两个缝片设置系统在整个工作波长(400~700 nm)内的光谱带宽,其最小光谱带宽优于5 nm。用488 nm激光和低压汞灯实际测量了几条谱线对应的狭缝位置并和理论值做了比较,结果显示实际狭缝位置和理论值的差值均小于0.1 mm。在全光谱和50 μm出射狭缝(对应2.5 nm光谱带宽)对老鼠肾脏组织进行了共聚焦光谱成像实验,获得了老鼠肾脏组织中DAPI标定的细胞核图像和Alexa Fluor®488标定的肾脏小球曲管图像,实现了对老鼠肾脏组织不同成分的区分。实验结果表明:提出的系统能够进行共聚焦光谱成像,扩大了共聚焦显微镜的适用范围。  相似文献   

19.
王珺  王燕  龚坚  唐微 《现代仪器》2009,15(4):50-52
阐述LSM510激光扫描共聚焦显微镜的工作原理及主要功能,提出LSM510激光扫描共聚焦显微镜的使用方法及荧光探针的选择。  相似文献   

20.
共聚焦激光扫描荧光显微镜扫描系统研制   总被引:3,自引:1,他引:3  
为适应三维光学微细加工及三维光学信息存储研究的需要,研制了共聚焦激光扫描荧光显微镜的工作台式扫描系统,扫描范围138μm×138μm.工作台采用压电陶瓷驱动器( PZT actuator)驱动的方式来获得高分辨率的位移,采用带柔性铰链的杠杆放大装置来获得较大的位移范围.描述了工作台的工作原理,并对其静态和动态性能进行了测试,实验表明这一扫描系统能很好的应用于共聚焦激光扫描荧光显微镜系统.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号