首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
We propose a structured illumination microscopy method to combine super resolution and optical sectioning in three‐dimensional (3D) samples that allows the use of two‐dimensional (2D) data processing. Indeed, obtaining super‐resolution images of thick samples is a difficult task if low spatial frequencies are present in the in‐focus section of the sample, as these frequencies have to be distinguished from the out‐of‐focus background. A rigorous treatment would require a 3D reconstruction of the whole sample using a 3D point spread function and a 3D stack of structured illumination data. The number of raw images required, 15 per optical section in this case, limits the rate at which high‐resolution images can be obtained. We show that by a succession of two different treatments of structured illumination data we can estimate the contrast of the illumination pattern and remove the out‐of‐focus content from the raw images. After this cleaning step, we can obtain super‐resolution images of optical sections in thick samples using a two‐beam harmonic illumination pattern and a limited number of raw images. This two‐step processing makes it possible to obtain super resolved optical sections in thick samples as fast as if the sample was two‐dimensional.  相似文献   

2.
Many papers have claimed the attainment of super‐resolution, i.e. resolution beyond that achieved classically, by measurement of the profile of a feature in the image. We argue that measurement of the contrast of the image of a dark bar on a bright background does not give a measure of resolution, but of detection sensitivity. The width of a bar that gives an intensity at the center of the bar of 0.735 that in the bright region (the same ratio as in the Rayleigh resolution criterion) is for the coherent case with central illumination. This figure, which compares with for the Abbe resolution limit with central illumination, holds for the classical case, and so is no indication of super‐resolution. Theoretical images for two points, two lines, arrays of lines, arrays of bars, and grating objects are compared. These results can be used a reference for experimental results, to determine if super‐resolution has indeed been attained. The history of the development of the theory of microscope resolution is outlined.  相似文献   

3.
Phase contrast microscopy allows the study of highly transparent yet detail‐rich specimens by producing intensity contrast from phase objects within the sample. Presented here is a generalized phase contrast illumination schema in which condenser optics are entirely abrogated, yielding a condenser‐free yet highly effective method of obtaining phase contrast in transmitted‐light microscopy. A ring of light emitting diodes (LEDs) is positioned within the light‐path such that observation of the objective back focal plane places the illuminating ring in appropriate conjunction with the phase ring. It is demonstrated that true Zernike phase contrast is obtained, whose geometry can be flexibly manipulated to provide an arbitrary working distance between illuminator and sample. Condenser‐free phase contrast is demonstrated across a range of magnifications (4–100×), numerical apertures (0.13–1.65NA) and conventional phase positions. Also demonstrated is condenser‐free darkfield microscopy as well as combinatorial contrast including Rheinberg illumination and simultaneous, colour‐contrasted, brightfield, darkfield and Zernike phase contrast. By providing enhanced and arbitrary working space above the preparation, a range of concurrent imaging and electrophysiological techniques will be technically facilitated. Condenser‐free phase contrast is demonstrated in conjunction with scanning ion conductance microscopy (SICM), using a notched ring to admit the scanned probe. The compact, versatile LED illumination schema will further lend itself to novel next‐generation transmitted‐light microscopy designs. The condenser‐free illumination method, using rings of independent or radially‐scanned emitters, may be exploited in future in other electromagnetic wavebands, including X‐rays or the infrared.  相似文献   

4.
The presence of systematic noise in images in high‐throughput microscopy experiments can significantly impact the accuracy of downstream results. Among the most common sources of systematic noise is non‐homogeneous illumination across the image field. This often adds an unacceptable level of noise, obscures true quantitative differences and precludes biological experiments that rely on accurate fluorescence intensity measurements. In this paper, we seek to quantify the improvement in the quality of high‐content screen readouts due to software‐based illumination correction. We present a straightforward illumination correction pipeline that has been used by our group across many experiments. We test the pipeline on real‐world high‐throughput image sets and evaluate the performance of the pipeline at two levels: (a) Z′‐factor to evaluate the effect of the image correction on a univariate readout, representative of a typical high‐content screen, and (b) classification accuracy on phenotypic signatures derived from the images, representative of an experiment involving more complex data mining. We find that applying the proposed post‐hoc correction method improves performance in both experiments, even when illumination correction has already been applied using software associated with the instrument. To facilitate the ready application and future development of illumination correction methods, we have made our complete test data sets as well as open‐source image analysis pipelines publicly available. This software‐based solution has the potential to improve outcomes for a wide‐variety of image‐based HTS experiments.  相似文献   

5.
We developed cryo‐scanning x‐ray diffraction microscopy, utilizing hard x‐ray ptychography at cryogenic temperature, for the noninvasive, high‐resolution imaging of wet, extended biological samples and report its first frozen‐hydrated imaging. Utilizing phase contrast at hard x‐rays, cryo‐scanning x‐ray diffraction microscopy provides the penetration power suitable for thick samples while retaining sensitivity to minute density changes within unstained samples. It is dose‐efficient and further minimizes radiation damage by keeping the wet samples at cryogenic temperature. We demonstrate these capabilities in two dimensions by imaging unstained frozen‐hydrated budding yeast cells, achieving a spatial resolution of 85 nm with a phase sensitivity of 0.0053 radians. The current work presents the feasibility of cryo‐scanning x‐ray diffraction microscopy for quantitative, high‐resolution imaging of unmodified biological samples extending to tens of micrometres.  相似文献   

6.
Multi‐emitter fitting algorithms have been developed to improve the temporal resolution of single‐molecule switching nanoscopy, but the molecular density range they can analyse is narrow and the computation required is intensive, significantly limiting their practical application. Here, we propose a computationally fast method, wedged template matching (WTM), an algorithm that uses a template matching technique to localise molecules at any overlapping molecular density from sparse to ultrahigh density with subdiffraction resolution. WTM achieves the localization of overlapping molecules at densities up to 600 molecules μm–2 with a high detection sensitivity and fast computational speed. WTM also shows localization precision comparable with that of DAOSTORM (an algorithm for high‐density super‐resolution microscopy), at densities up to 20 molecules μm–2, and better than DAOSTORM at higher molecular densities. The application of WTM to a high‐density biological sample image demonstrated that it resolved protein dynamics from live cell images with subdiffraction resolution and a temporal resolution of several hundred milliseconds or less through a significant reduction in the number of camera images required for a high‐density reconstruction. WTM algorithm is a computationally fast, multi‐emitter fitting algorithm that can analyse over a wide range of molecular densities. The algorithm is available through the website. https://doi.org/10.17632/bf3z6xpn5j.1  相似文献   

7.
The new high‐sensitive and high‐resolution technique, Re‐scan Confocal Microscopy (RCM), is based on a standard confocal microscope extended with a re‐scan detection unit. The re‐scan unit includes a pair of re‐scanning mirrors that project the emission light onto a camera in a scanning manner. The signal‐to‐noise ratio of Re‐scan Confocal Microscopy is improved by a factor of 4 compared to standard confocal microscopy and the lateral resolution of Re‐scan Confocal Microscopy is 170 nm (compared to 240 nm for diffraction limited resolution, 488 nm excitation, 1.49 NA). Apart from improved sensitivity and resolution, the optical setup of Re‐scan Confocal Microscopy is flexible in its configuration in terms of control of the mirrors, lasers and filters. Because of this flexibility, the Re‐scan Confocal Microscopy can be configured to address specific biological applications. In this paper, we explore a number of possible configurations of Re‐scan Confocal Microscopy for specific biomedical applications such as multicolour, FRET, ratio‐metric (e.g. pH and intracellular Ca2+ measurements) and FRAP imaging.  相似文献   

8.
Aberration‐corrected scanning transmission electron microscopes are able to form electron beams smaller than 100 pm, which is about half the size of an average atom. Probing materials with such beams leads to atomic‐resolution images, electron energy loss and energy‐dispersive X‐ray spectra obtained from single atomic columns and even single atoms, and atomic‐resolution elemental maps. We review briefly how such electron beams came about, and show examples of applications. We also summarize recent developments that are propelling aberration‐corrected scanning transmission electron microscopes in new directions, such as complete control of geometric aberration up to fifth order, and ultra‐high‐energy resolution EELS that is allowing vibrational spectroscopy to be carried out in the electron microscope.  相似文献   

9.
Serial block‐face scanning electron microscopy (SBEM) is becoming increasingly popular for a wide range of applications in many disciplines from biology to material sciences. This review focuses on applications for circuit reconstruction in neuroscience, which is one of the major driving forces advancing SBEM. Neuronal circuit reconstruction poses exceptional challenges to volume EM in terms of resolution, field of view, acquisition time and sample preparation. Mapping the connections between neurons in the brain is crucial for understanding information flow and information processing in the brain. However, information on the connectivity between hundreds or even thousands of neurons densely packed in neuronal microcircuits is still largely missing. Volume EM techniques such as serial section TEM, automated tape‐collecting ultramicrotome, focused ion‐beam scanning electron microscopy and SBEM (microtome serial block‐face scanning electron microscopy) are the techniques that provide sufficient resolution to resolve ultrastructural details such as synapses and provides sufficient field of view for dense reconstruction of neuronal circuits. While volume EM techniques are advancing, they are generating large data sets on the terabyte scale that require new image processing workflows and analysis tools. In this review, we present the recent advances in SBEM for circuit reconstruction in neuroscience and an overview of existing image processing and analysis pipelines.  相似文献   

10.
Several dedicated commercial lab‐based micro‐computed tomography (μCT) systems exist, which provide high‐resolution images of samples, with the capability to also deliver in‐line phase contrast. X‐ray phase contrast is particularly beneficial when visualizing very small features and weakly absorbing samples. The raw measured projections will include both phase and absorption effects. Extending our previous work that addressed the optimization of experimental conditions at the commercial ZEISS Xradia 500 Versa system, single‐distance phase‐contrast imaging is demonstrated on complex biological and material samples. From data captured at this system, we demonstrate extraction of the phase signal or the correction of the mixed image for the phase shift, and show how this procedure increases the contrast and removes artefacts. These high‐quality images, measured without the use of a synchrotron X‐ray source, demonstrate that highly sensitive, micrometre‐resolution imaging of 3D volumes is widely accessible using commercially advanced laboratory devices.  相似文献   

11.
We present an integrated light‐electron microscope in which an inverted high‐NA objective lens is positioned inside a scanning electron microscope (SEM). The SEM objective lens and the light objective lens have a common axis and focal plane, allowing high‐resolution optical microscopy and scanning electron microscopy on the same area of a sample simultaneously. Components for light illumination and detection can be mounted outside the vacuum, enabling flexibility in the construction of the light microscope. The light objective lens can be positioned underneath the SEM objective lens during operation for sub‐10 μm alignment of the fields of view of the light and electron microscopes. We demonstrate in situ epifluorescence microscopy in the SEM with a numerical aperture of 1.4 using vacuum‐compatible immersion oil. For a 40‐nm‐diameter fluorescent polymer nanoparticle, an intensity profile with a FWHM of 380 nm is measured whereas the SEM performance is uncompromised. The integrated instrument may offer new possibilities for correlative light and electron microscopy in the life sciences as well as in physics and chemistry.  相似文献   

12.
The spatial resolution of a stimulated emission depletion (STED) microscope is theoretically unlimited and practically determined by the signal‐to‐noise ratio. Typically, an increase of the STED beam's power leads to an improvement of the effective resolution. However, this improvement may vanish because an increased STED beam's power is often accompanied by an increased photobleaching, which worsen the effective resolution by reducing the signal strength. A way to lower the photobleaching in pulsed STED (P‐STED) implementations is to reduce the peak intensity lengthening the pulses duration (for a given average STED beam's power). This also leads to a reduction of the fluorophores quenching, thus a reduction of the effective resolution, but the time‐gated detection was proved to be successful in recovering these reductions. Here we demonstrated that a subnanosecond fiber laser beam (pulse width ∼600 ps) reduces the photobleaching with respect to a traditional stretched hundreds picosecond (∼200 ps) beam provided by a Ti:Sapphire laser, without any effective spatial resolution lost.  相似文献   

13.
In this study, we compare two evolving techniques for obtaining high‐resolution 3D anatomical data of a mouse specimen. On the one hand, we investigate cryotome‐based planar epi‐illumination imaging (cryo‐imaging). On the other hand, we examine X‐ray phase‐contrast micro‐computed tomography (micro‐CT) using synchrotron radiation. Cryo‐imaging is a technique in which an electron multiplying charge coupled camera takes images of a cryo‐frozen specimen during the sectioning process. Subsequent image alignment and virtual stacking result in volumetric data. X‐ray phase‐contrast imaging is based on the minute refraction of X‐rays inside the specimen and features higher soft‐tissue contrast than conventional, attenuation‐based micro‐CT. To explore the potential of both techniques for studying whole mouse disease models, one mouse specimen was imaged using both techniques. Obtained data are compared visually and quantitatively, specifically with regard to the visibility of fine anatomical details. Internal structure of the mouse specimen is visible in great detail with both techniques and the study shows in particular that soft‐tissue contrast is strongly enhanced in the X‐ray phase images compared to the attenuation‐based images. This identifies phase‐contrast micro‐CT as a powerful tool for the study of small animal disease models.  相似文献   

14.
We report an ingenious method of super‐resolution optical microscopy utilizing scannable cantilever‐combined microsphere. By scanning the microsphere over the sample surface in a cantilever‐combined microsphere‐sample contact state, super‐resolution images can be acquired at arbitrary sample regions through near‐field information collection by the microsphere. In addition, such a state can effectively reduce the possibility of breaking the cantilever and damaging the microsphere or sample surface. This work has developed a new method and technique of sub‐diffraction‐limit optical microscopy, and can be practically applied in various fields of micro/nanoscopy. Microsc. Res. Tech. 78:1128–1132, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

15.
Light‐sheet fluorescence microscopy (LSFM) is an optical sectioning technique capable of rapid three‐dimensional (3D) imaging of a wide range of specimens with reduced phototoxicity and superior background rejection. However, traditional light‐sheet generation approaches based on elliptical or circular Gaussian beams suffer an inherent trade‐off between light‐sheet thickness and area over which this thickness is preserved. Recently, an increase in light‐sheet uniformity was demonstrated using rapid biaxial Gaussian beam scanning along the lateral and beam propagation directions. Here we apply a similar scanning concept to an elliptical beam generated by a cylindrical lens. In this case, only z‐scanning of the elliptical beam is required and hence experimental implementation of the setup can be simplified. We introduce a simple dimensionless uniformity statistic to better characterize scanned light‐sheets and experimentally demonstrate custom tailored uniformities up to a factor of 5 higher than those of unscanned elliptical beams. This technique offers a straightforward way to generate and characterize a custom illumination profile that provides enhanced utilization of the detector dynamic range and field of view, opening the door to faster and more efficient 2D and 3D imaging.  相似文献   

16.
Super‐resolution localisation microscopy techniques depend on uniform illumination across the field of view, otherwise the resolution is degraded, resulting in imaging artefacts such as fringes. Lasers are currently the light source of choice for switching fluorophores in PALM/STORM methods due to their high power and narrow bandwidth. However, the high coherence of these sources often creates interference phenomena in the microscopes, with associated fringes/speckle artefacts in the images. We quantitatively demonstrate the use of a polymer membrane speckle scrambler to reduce the effect of the coherence phenomena. The effects of speckle in the illumination plane, at the camera and after software localisation of the fluorophores, were characterised. Speckle phenomena degrade the resolution of the microscope at large length scales in reconstructed images, effects that were suppressed by the speckle scrambler, but the small length scale resolution is unchanged at ~30 nm.  相似文献   

17.
The refractive index (RI) of a sample as an endogenous contrast agent plays an important role in transparent live cell imaging. In tomographic phase microscopy (TPM), 3D quantitative RI maps can be reconstructed based on the measured projections of the RI in multiple directions. The resolution of the RI maps not only depends on the numerical aperture of the employed objective lens, but also is determined by the accuracy of the quantitative phase of the sample measured at multiple scanning illumination angles. This paper reports an analogous on‐axis interference TPM, where the interference angle between the sample and reference beams is kept constant for projections in multiple directions to improve the accuracy of the phase maps and the resolution of RI tomograms. The system has been validated with both silica beads and red blood cells. Compared with conventional TPM, the proposed system acquires quantitative RI maps with higher resolution (420 nm @λ = 633 nm) and signal‐to‐noise ratio that can be beneficial for live cell imaging in biomedical applications.  相似文献   

18.
Bacterial cells often contain dense granules. Among these, polyphosphate bodies (PPBs) store inorganic phosphate for a variety of essential functions. Identification of PPBs has until now been accomplished by analytical methods that required drying or chemically fixing the cells. These methods entail large electron doses that are incompatible with low‐dose imaging of cryogenic specimens. We show here that Scanning Transmission Electron Microscopy (STEM) of fully hydrated, intact, vitrified bacteria provides a simple means for mapping of phosphorus‐containing dense granules based on quantitative sensitivity of the electron scattering to atomic number. A coarse resolution of the scattering angles distinguishes phosphorus from the abundant lighter atoms: carbon, nitrogen and oxygen. The theoretical basis is similar to Z contrast of materials science. EDX provides a positive identification of phosphorus, but importantly, the method need not involve a more severe electron dose than that required for imaging. The approach should prove useful in general for mapping of heavy elements in cryopreserved specimens when the element identity is known from the biological context.  相似文献   

19.
Axial phase-darkfield-contrast (APDC) has been developed as an illumination technique in light microscopy which promises significant improvements and a higher variability in imaging of several transparent 'problem specimens'. With this method, a phase contrast image is optically superimposed on an axial darkfield image so that a partial image based on the principal zeroth order maximum (phase contrast) interferes with an image, which is based on the secondary maxima (axial darkfield). The background brightness and character of the resulting image can be continuously modulated from a phase contrast-dominated to a darkfield-dominated character. In order to achieve this illumination mode, normal objectives for phase contrast have to be fitted with an additional central light stopper needed for axial (central) darkfield illumination. In corresponding condenser light masks, a small perforation has to be added in the centre of the phase contrast providing light annulus. These light modulating elements are properly aligned when the central perforation is congruent with the objective's light stop and the light annulus is conjugate with the phase ring. The breadth of the condenser light annulus and thus the intensity of the phase contrast partial image can be regulated with the aperture diaphragm. Additional contrast effects can be achieved when both illuminating light components are filtered at different colours. In this technique, the axial resolution (depth of field) is significantly enhanced and the specimen's three-dimensional appearance is accentuated with improved clarity as well as fine details at the given resolution limit. Typical artefacts associated with phase contrast and darkfield illumination are reduced in our methods.  相似文献   

20.
An original scanning near‐field cathodoluminescence microscope for nanostructure characterization has been developed and successfully tested. By using a bimorph piezoelectric stack both as actuator and detector, the developed setup constitutes a real improvement compared to previously reported SEM‐based solutions. The technique combines a scanning probe and a scanning electron microscope in order to simultaneously offer near‐field cathodoluminescence and topographic images of the sample. Share‐force topography and cathodoluminescence measurements on GaN, SiC and ZnO nanostructures using the developed setup are presented showing a nanometric resolution in both topography and cathodoluminescence images with increased sensitivity compared to classical luminescence techniques.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号