首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The purpose of the study was to gather information about the actual ventilation and indoor air quality and to evaluate the differences between houses and apartments with different ventilation systems. A sample of 242 dwellings in the Helsinki metropolitan area was studied over periods of no weeks during the 1988-1989 heating season. The mean air-exchange rates had a high variation (average 0.52 l/h, range 0.07-1.55 l/h). The ASHRAE minimum value of 0.35 l/h was not achieved in 28% of the dwellings. The air-exchange rates were significantly her in the houses than in the apartments (averages 0.45/0.64 l/h, p < 0.001); in the natural ventilation systems they, were slightly her than in the mechanical systems. The average temperature in the bedrooms was approximately 22 °C (range 18–27 °C), slightly but significantly higher in the apartment than in the houses. The average dust depositions were higher in the balanced ventilation systems than in the other systems. The median radon concentration was 82 Bq/m3 (range 5-866 Bq/m3); the Finnish target value of 200 Bq/m3 was exceeded in 17% of the houses but in none of the apartment. The measurements indicate that the indoor air quality in Finnish dwellings is not always satisfactory with reference to human health and comfort.  相似文献   

2.
Radon‐222 gas arises from the radioactive decay of radium‐226 and has a half‐life of 3.8 days. This gas percolates up through soil into buildings, and if it is not evacuated, there can be much higher exposure levels indoors than outdoors, which is where human exposure occurs. Radon exposure is classified as a human carcinogen, and new Danish homes must be constructed to ensure indoor radon levels below 100 Bq/m3. Our purpose was to assess how well 200 newly constructed single detached homes perform according to building regulations pertaining to radon and identify the association between indoor radon in these homes and municipality, home age, floor area, floor level, basement, and outer wall and roof construction. Median (5–95 percentile) indoor radon levels were 36.8 (9.0–118) Bq/m3, but indoor radon exceeded 100 Bq/m3 in 14 of these new homes. The investigated variables explained nine percent of the variation in indoor radon levels, and although associations were positive, none of these were statistically significant. In this study, radon levels were generally low, but we found that 14 (7%) of the 200 new homes had indoor radon levels over 100 Bq/m3. More work is needed to determine the determinants of indoor radon.  相似文献   

3.
Residential energy efficiency and ventilation retrofits (eg, building weatherization, local exhaust ventilation, HVAC filtration) can influence indoor air quality (IAQ) and occupant health, but these measures’ impact varies by occupant activity. In this study, we used the multizone airflow and IAQ analysis program CONTAM to simulate the impacts of energy retrofits on indoor concentrations of PM2.5 and NO2 in a low‐income multifamily housing complex in Boston, Massachusetts (USA). We evaluated the differential impact of residential activities, such as low‐ and high‐emission cooking, cigarette smoking, and window opening, on IAQ across two seasons. We found that a comprehensive package of energy and ventilation retrofits was resilient to a range of occupant activities, while less holistic approaches without ventilation improvements led to increases in indoor PM2.5 or NO2 for some populations. In general, homes with simulated concentration increases included those with heavy cooking and no local exhaust ventilation, and smoking homes without HVAC filtration. Our analytical framework can be used to identify energy‐efficient home interventions with indoor retrofit resiliency (ie, those that provide IAQ benefits regardless of occupant activity), as well as less resilient retrofits that can be coupled with behavioral interventions (eg, smoking cessation) to provide cost‐effective, widespread benefits.  相似文献   

4.
An empirical statistical model is described for the use of indoor radon monitoring data as an indicator of the areal radon risk from soil and bedrock. The percentages of future homes expected to have radon concentrations exceeding the design level of 200 Bq/m3 unless constructed to provide protection against the entry of radon were assessed. The radon prognosis was made for different subareas, soil types and foundation types. This kind of report is used by the health and building authorities. In this study, 2689 indoor radon measurements were made in one of Finland's most radon-prone areas, consisting of eleven municipalities with a total area of 4600 km2 and a population of 186,000. Radon concentrations were seasonally adjusted. Data on the location, geology and construction of buildings were determined from maps and questionnaires. The measurements covered different kinds of geological units in the area. The radon risk is highest in the gravel-dominated subarea in an ice-marginal formation and lowest in the northern half of the area in buildings constructed on bedrock. In these two areas, the design level of 200 Bq/m3 would be exceeded in 99% and 39% of new houses with slab-on-grade.  相似文献   

5.
This paper presents pollutant concentrations and performance data for code-required mechanical ventilation equipment in 23 low-income apartments at 4 properties constructed or renovated 2013-2017. All apartments had natural gas cooking burners. Occupants pledged to not use windows for ventilation during the study but several did. Measured airflows of range hoods and bathroom exhaust fans were lower than product specifications. Only eight apartments operationally met all ventilation code requirements. Pollutants measured over one week in each apartment included time-resolved fine particulate matter (PM2.5), nitrogen dioxide (NO2), formaldehyde and carbon dioxide (CO2) and time-integrated formaldehyde, NO2 and nitrogen oxides (NOX). Compared to a recent study of California houses with code-compliant ventilation, apartments were smaller, had fewer occupants, higher densities, and higher mechanical ventilation rates. Mean PM2.5, formaldehyde, NO2, and CO2 were 7.7 µg/m3, 14.1, 18.8, and 741 ppm in apartments; these are 4% lower, 25% lower, 165% higher, and 18% higher compared to houses with similar cooking frequency. Four apartments had weekly PM2.5 above the California annual outdoor standard of 12 µg/m3 and also discrete days above the World Health Organization 24-hour guideline of 25 µg/m3. Two apartments had weekly NO2 above the California annual outdoor standard of 30 ppb.  相似文献   

6.
Energy retrofits can reduce air exchange, raising the concern of whether indoor radon and moisture levels could increase. This pre/post-intervention study explored whether simple radon interventions implemented in conjunction with energy retrofits can prevent increases in radon and moisture levels. Treatment homes (n = 98) were matched with control (no energy retrofits or radon intervention) homes (n = 12). Control homes were matched by geographic location and foundation type. t-tests were used to determine whether post-energy retrofit radon and moisture level changes in treatment homes significantly differed from those in control homes. The radon interventions succeeded in preventing statistically significant increases in first floor radon using arithmetic (p = 0.749) and geometric means (p = 0.120). In basements, arithmetic (p = 0.060) and geometric (p = 0.092) mean radon levels statistically significantly increased, consistent with previous studies which found that basement radon levels may increase even if first floor levels remain unchanged. Changes in infiltration were related to changes in radon (p = 0.057 in basements; p = 0.066 on first floors). Only 58% of the change in infiltration was due to air sealing, with the rest due to weather changes. There was no statistically significant association between air sealing itself and radon levels on the first floor (p = 0.664). Moisture levels also did not significantly increase.  相似文献   

7.

Existing buildings constitute a large portion of the UK’s housing stock. Refurbishment of existing buildings can, therefore, have an important role in achieving the UK government’s CO2 reduction targets. While building regulations and rating frameworks mainly focus on the improvements of the operational performance of buildings, Life Cycle Analysis is considered to be a more appropriate framework to account for long–term CO2 savings. This study evaluates a range of retrofit approaches (simple, medium, and deep), in terms of Life Cycle Carbon Footprint applied on a terraced house—one of the most common housing archetypes in London. The initial state of the original building has also been examined assuming three initial states (never refurbished, refurbished in compliance with the 1976 and with the 2000 building regulations). Results showed that for all initial state scenarios, deep retrofit achieved the lowest life cycle carbon emissions, in absolute figures, compared to the simple and medium retrofits. Simple retrofit packages, on the other hand, achieved quick and significant improvements, especially in buildings with poor initial thermal conditions. The study also indicated that retrofit packages applied on highly efficient building fabrics result in longer carbon payback time periods. The study recommends establishing a ‘staggered’ retrofitting approach, which pushes for ‘older building first’ and ‘simple retrofit packages first’, as these gain quick CO2 savings. Deep retrofit packages and treatment of relatively new buildings should be implemented at a later stage, to push buildings further to Zero–Carbon target.

  相似文献   

8.
In this study, the overall performance of a biofilter was evaluated in terms of its elimination capacity by using 3-D mesh techniques. The overall results indicate that the agreement between experimental data and model predictions is excellent for benzene, toluene, ethylbenzene and o-xylene (BTEX). In this study, the maximum removal rate (r max) values for BTEX were 0.0117, 0.0126, 0.0081 and 0.0146 g m–3 h–1, and the half-saturation constant (KS ) values were calculated to be 0.269, 0.297, 0.156 and 0.394 g m–3, respectively. For this system, the coefficients of determination (r 2) of BTEX compounds were greater than 0.97. The BTEX concentration profiles along the depth were also determined using a convection–diffusion reactor (CDR) model. The sums of squares of the errors (SSEs) of BTEX were 0.0078, 0.0059, 0.0129 and 0.0269, respectively, with r 2 values greater than 0.99 for all four compounds at low concentrations.  相似文献   

9.
Solid fuel burning cookstoves are a major source of household air pollution (HAP) and a significant environmental health risk in Sri Lanka. We report results of the first field study in Sri Lanka to include direct measurements of both real‐time indoor concentrations and personal exposures of fine particulate matter (PM2.5) in households using the two most common stove types in Sri Lanka. A purposive sample of 53 households was selected in the rural community of Kopiwatta in central Sri Lanka, roughly balanced for stove type (traditional or improved ‘Anagi’) and ventilation (chimney present or absent). At each household, 48‐h continuous real‐time measurements of indoor kitchen PM2.5 and personal (primary cook) PM2.5 concentrations were measured using the RTI MicroPEM? personal exposure monitor. Questionnaires were used to collect data related to household demographics, characteristics, and self‐reported health symptoms. All primary cooks were female and of an average age of 47 years, with 66% having completed primary education. Median income was slightly over half the national median monthly income. Use of Anagi stoves was positively associated with a higher education level of the primary cook (P = 0.026), although not associated with household income (P = 0.18). The MicroPEM monitors were well‐received by participants, and this study's valid data capture rate exceeded 97%. Participant wearing compliance during waking hours was on average 87.2% on Day 1 and 83.3% on Day 2. Periods of non‐compliance occurred solely during non‐cooking times. The measured median 48‐h average indoor PM2.5 concentration for households with Anagi stoves was 64 μg/m3 if a chimney was present and 181 μg/m3 if not. For households using traditional stoves, these values were 70 μg/m3 if a chimney was present and 371 μg/m3 if not. Overall, measured indoor PM2.5 concentrations ranged from a minimum of 33 μg/m3 to a maximum of 940 μg/m3, while personal exposure concentrations ranged from 34 to 522 μg/m3. Linear mixed effects modeling of the dependence of indoor concentrations on stove type and presence or absence of chimney showed a significant chimney effect (65% reduction; P < 0.001) and an almost significant stove effect (24% reduction; P = 0.054). Primary cooks in households without chimneys were exposed to substantially higher levels of HAP than those in households with chimneys, while exposures in households with traditional stoves were moderately higher than those with improved Anagi stoves. As expected, simultaneously measuring both indoor concentrations and personal exposure levels indicate significant exposure misclassification bias will likely result from the use of a stationary monitor as a proxy for personal exposure. While personal exposure monitoring is more complex and expensive than deploying simple stationary devices, the value an active personal PM monitor like the MicroPEM adds to an exposure study should be considered in future study designs.  相似文献   

10.
PM2.5 exposure is associated with significant health risk. Exposures in homes derive from both outdoor and indoor sources, with emissions occurring primarily in discrete events. Data on emission event magnitudes and schedules are needed to support simulation‐based studies of exposures and mitigations. This study applied an identification and characterization algorithm to quantify time‐resolved PM2.5 emission events from data collected during 224 days of monitoring in 18 California apartments with low‐income residents. We identified and characterized 836 distinct events with median and mean values of 12 and 30 mg emitted mass, 16 and 23 minutes emission duration, 37 and 103 mg/h emission rates, and pseudo‐first–order decay rates of 1.3 and 2.0/h. Mean event‐averaged concentrations calculated using the determined event characteristics agreed to within 6% of measured values for 14 of the apartments. There were variations in event schedules and emitted mass across homes, with few events overnight and most emissions occurring during late afternoons and evenings. Event characteristics were similar during weekdays and weekends. Emitted mass was positively correlated with number of residents (Spearman coefficient, ρ=.10), bedrooms (ρ=.08), house volume (ρ=.29), and indoor‐outdoor CO2 difference (ρ=.27). The event schedules can be used in probabilistic modeling of PM2.5 in low‐income apartments.  相似文献   

11.
Few measurements of exposure to secondhand smoke (SHS) in close proximity to a smoker are available. Recent health studies have demonstrated an association between acute (<2 h) exposures to high concentrations of SHS and increased risk of cardiovascular and respiratory disease. We performed 15 experiments inside naturally ventilated homes and 16 in outdoor locations, each with 2–4 non‐smokers sitting near a cigarette smoker. The smoker's and non‐smokers' real‐time exposures to PM2.5 from SHS were measured by using TSI SidePak monitors to sample their breathing zones. In 87% of the residential indoor experiments, the smoker received the highest average exposure to SHS, with PM2.5 concentrations ranging from 50–630 μg/m3. During the active smoking period, individual non‐smokers sitting within approximately 1 m of a smoker had average SHS exposures ranging from negligible up to >160 μg/m3 of PM2.5. The average incremental exposure of the non‐smokers was higher indoors (42 μg/m3, = 35) than outdoors (29 μg/m3, = 47), but the overall indoor and outdoor frequency distributions were similar. The 10‐s PM2.5 averages during the smoking periods showed great variability, with multiple high concentrations of short duration (microplumes) both indoors and outdoors.  相似文献   

12.
Polychlorinated biphenyl (PCB) contamination of buildings continues to pose an exposure threat, even decades after their application in the form of calks and other building materials. In this research, we investigate the ability of clothing to sorb PCBs from contaminated air and thereby influence exposure. The equilibrium concentration of PCB‐28 and PCB‐52 was quantified for nine used clothing fabrics exposed for 56 days to air in a Danish apartment contaminated with PCBs. Fabric materials included pure materials such as cotton and polyester, or blends of polyester, cotton, viscose/rayon, and/or elastane. Air concentrations were fairly stable over the experimental period, with PCB‐28 ranging from 350 to 430 ng/m3 and PCB‐52 ranging from 460 to 550 ng/m3. Mass accumulated in fabric ranged from below detection limits to 4.5 mg/g of fabric. Cotton or materials containing elastane sorbed more than polyester materials on a mass basis. Mass‐normalized partition coefficients above detection limits ranged from 105.7 to 107.0 L/kg. Clothing acts as a reservoir for PCBs that extends dermal exposure, even when outside or in uncontaminated buildings.  相似文献   

13.
The objective of this study was to quantify the influence of ventilation systems on indoor particle concentrations in residential buildings. Fifteen occupied, single‐family apartments were selected from three sites. The three sites have three different ventilation systems: unbalanced mechanical ventilation, balanced mechanical ventilation, and natural ventilation. Field measurements were conducted between April and June 2012, when outdoor air temperatures were comfortable. Number concentrations of particles, PM2.5 and CO2, were continuously measured both outdoors and indoors. In the apartments with natural ventilation, I/O ratios of particle number concentrations ranged from 0.56 to 0.72 for submicron particles, and from 0.25 to 0.60 for particles larger than 1.0 μm. The daily average indoor particle concentration decreased to 50% below the outdoor level for submicron particles and 25% below the outdoor level for fine particles, when the apartments were mechanically ventilated. The two mechanical ventilation systems reduced the I/O ratios by 26% for submicron particles and 65% for fine particles compared with the natural ventilation. These results showed that mechanical ventilation can reduce exposure to outdoor particles in residential buildings.  相似文献   

14.
In order to estimate the mass concentrations of benzene (B), toluene (T), ethylbenzene (E) and xylenes (X) inside air environment of buses and to analyze the influencing factors of the BTEX pollution levels, 22 public buses were investigated in Changsha, China. The interior air was collected through activated charcoal adsorption tubes and then the air samples were analyzed with thermally desorbed gas chromatograph. The mass concentrations ranged from 21.3 to 106.4 μg/m3 for benzene, from 53.5 to 266.0 μg/m3 for toluene, from 19.6 to 95.9 μg/m3 for ethylbenzene and from 46.9 to 234.8 μg/m3 for xylenes. Their mean values were 68.7, 179.7, 62.5 and 151.8 μg/m3, respectively. The rates of buses tested where the interior concentrations exceeded the limit levels of Chinese Indoor Air Quality Standard were 45.5% for toluene and 13.6% for xylenes. The BTEX levels increased when in-car temperature or relative humidity rose, and decreased when car age or travel distance increased. The BTEX concentrations were higher in leather trims buses than in non-leather trims ones, in air-conditioned buses than in non-air-conditioned ones, and in high-grade buses than in low-grade ones. According to the analysis of multiple linear regression equation, car age and in-car temperature were two most important factors influencing the BTEX pollution levels in the cabins of public buses.  相似文献   

15.
This study summarizes measured data on energy savings from conservation retrofits in existing residential buildings. We have compiled building performance data on approximately 115 retrofit projects (almost twice the size of the initial study) that we put into four general categories: utility-sponsored conservation programs, low-income weatherization programs, research studies, and multifamily buildings. The sample size for each project varies widely, ranging from individual buildings to 33 000 homes. Retrofits to the building shell, principally insulation of exterior surfaces, window treatments, and infiltration-reduction measures, are the most popular, although data on various heating system retrofits are now available. The average retrofit investment per unit in multifamily buildings is approximately $695, far lower than the average of $1350 spent in single-family residences. The median annual space heat savings in the four categories range from 15 to 38 GJ. Savings achieved are typically 20%–30% of pre-retrofit space heating energy use although large variations are observed both in energy savings and in costs per unit of energy saved. Even given the wide range in savings, most retrofit projects are cost-effective. Approximately 75%–80% of the retrofit projects have costs of conserved energy below their respective space heating fuel or electricity prices.  相似文献   

16.
Thermal conditions and indoor concentrations of aldehydes, volatile organic compounds (VOCs), and NO2 were investigated in 19 occupied temporary houses in 15 temporary housing estates constructed in Minamisoma City, Fukushima, Japan. The data were collected in winter, spring, and summer in January to July 2012. Thermal conditions in temporary log houses in the summer were more comfortable than those in pre‐fabricated houses. In the winter, the indoor temperature was uncomfortably low in all of the houses, particularly the temporary log houses. Indoor air concentrations for most aldehydes and VOCs were much lower than the indoor guidelines, except for those of p‐dichlorobenzene, acetaldehyde, and total VOCs. The indoor p‐dichlorobenzene concentrations exceeded the guideline (240 μg/m3) in 18% of the temporary houses, and the 10?3 cancer risk level (91 μg/m3) was exceeded in winter in 21% due to use of moth repellents by the occupants. Indoor acetaldehyde concentrations exceeded the guideline (48 μg/m3) in about half of the temporary houses, likely originating from the wooden building materials. Indoor NO2 concentrations in the temporary houses were significantly higher in houses where combustion heating appliances were used (0.17 ± 0.11 ppm) than in those where they were not used (0.0094 ± 0.0065 ppm).  相似文献   

17.
Polycyclic aromatic hydrocarbons (PAHs) are a group of pollutants of widespread concerns. Gaseous and size‐segregated particulate‐phase PAHs were collected in indoor and outdoor air in rural households. Personal exposure was measured and compared to the ingestion exposure. The average concentrations of 28 parent PAHs and benzo(a)pyrene (BaP) were 9000 ± 8390 and 131 ± 236 ng/m3 for kitchen, 2590 ± 2270 and 43 ± 95 ng/m3 for living room, and 2800 ± 3890 and 1.6 ± 0.7 ng/m3 for outdoor air, respectively. The mass percent of high molecular weight (HMW) compounds with 5–6 rings contributed 1.3% to total 28 parent PAHs. Relatively higher fractions of HMW PAHs were found in indoor air compared to outdoor air. Majorities of particle‐bound PAHs were found in the finest PM0.25, and the highest levels of fine PM0.25‐bound PAHs were in the kitchen using peat and wood as energy sources. The 24‐h personal PAH exposure concentration was 2100 ± 1300 ng/m3. Considering energies, exposures to those using wood were the highest. The PAH inhalation exposure comprised up to about 30% in total PAH exposure through food ingestion and inhalation, and the population attributable fraction (PAF) for lung cancer in the region was 0.85%. The risks for inhaled and ingested intakes of PAHs were 1.0 × 10?5 and 1.1 × 10?5, respectively.  相似文献   

18.
Growing evidence links household air pollution exposure from biomass cookstoves with elevated blood pressure. We assessed cross‐sectional associations of 24‐hour mean concentrations of personal and kitchen fine particulate matter (PM2.5), black carbon (BC), and stove type with blood pressure, adjusting for confounders, among 147 women using traditional or cleaner‐burning Justa stoves in Honduras. We investigated effect modification by age and body mass index. Traditional stove users had mean (standard deviation) personal and kitchen 24‐hour PM2.5 concentrations of 126 μg/m3 (77) and 360 μg/m3 (374), while Justa stove users’ exposures were 66 μg/m3 (38) and 137 μg/m3 (194), respectively. BC concentrations were similarly lower among Justa stove users. Adjusted mean systolic blood pressure was 2.5 mm Hg higher (95% CI, 0.7‐4.3) per unit increase in natural log‐transformed kitchen PM2.5 concentration; results were stronger among women of 40 years or older (5.2 mm Hg increase, 95% CI, 2.3‐8.1). Adjusted odds of borderline high and high blood pressure (categorized) were also elevated (odds ratio = 1.5, 95% CI, 1.0‐2.3). Some results included null values and are suggestive. Results suggest that reduced household air pollution, even when concentrations exceed air quality guidelines, may help lower cardiovascular disease risk, particularly among older subgroups.  相似文献   

19.
High levels of PM2.5 exposure and associated health risks are of great concern in rural China. For this study, we used portable PM2.5 monitors for monitoring concentrations online, recorded personal time‐activity patterns, and analyzed the contribution from different microenvironments in rural areas of the Yangtze River Delta, China. The daily exposure levels of rural participants were 66 μg/m3 (SD 40) in winter and 65 μg/m3 (SD 16) in summer. Indoor exposure levels were usually higher than outdoor levels. The exposure levels during cooking in rural kitchens were 140 μg/m3 (SD 116) in winter and 121 μg/m3 (SD 70) in summer, the highest in all microenvironments. Winter and summer values were 252 μg/m3 (SD 103) and 204 μg/m3 (SD 105), respectively, for rural people using biomass for fuel, much higher than those for rural people using LPG and electricity. By combining PM2.5concentrations and time spent in different microenvironments, we found that 92% (winter) and 85% (summer) of personal exposure to PM2.5in rural areas was attributable to indoor microenvironments, of which kitchens accounted for 24% and 27%, respectively. Consequently, more effective policies and measures are needed to replace biomass fuel with LPG or electricity, which would benefit the health of the rural population in China.  相似文献   

20.
Recently adaptive thermal-comfort criteria have been introduced in the international indoor-climate standards to reduce the heating/cooling energy requirements. In 2008, the Finnish Society of Indoor Air Quality (FiSIAQ) developed the national adaptive thermal-comfort criteria of Finland. The current study evaluates the impact of the Finnish Criteria on energy performance in an office building. Two fully mechanically air-conditioned single offices are taken as representative zones. A simulation-based optimization scheme (a combination of IDA-ICE 4.0 and a multi-objective genetic-algorithm from MATLAB-2008a) is employed to determine the minimum primary energy use and the minimum room cooling-equipment size required for different thermal comfort levels. The applicability of implementing energy-saving measures such as night ventilation, night set-back temperature, day lighting as well as optimal building envelope and optimal HVAC settings are addressed by investigating 24 design variables. The results show that, on average, an additional 10 kWh/(m2 a) primary energy demand and a larger 10 W/m2 room cooling-equipment size are required to improve the thermal comfort from medium (S2) to high-quality (S1) class; higher thermal comfort levels limit the use of night ventilation and water radiator night-set back options. Compared with the ISO EN 7730-2005 standard, the Finnish criterion could slightly decrease the heating/cooling equipment size. However, it significantly increases both the heating and cooling energy demand; the results show 32.8% increase in the primary energy demand. It is concluded that the Finnish criterion-2008 is strict and does not allow for energy-efficient solutions in standard office buildings.  相似文献   