1.
高压直流电缆接头与终端为电缆系统故障的多发点,其击穿强度为直流输电系统安全稳定运行的重要基础。文中以±320 kV高压直流海底电缆中交联聚乙烯(cross linked polyethylene,XLPE)/三元乙丙橡胶(ethylene propylene diene monomer,EPDM)附件为研究对象。首先,研究电缆及附件负荷循环耐压试验,发现附件界面为击穿薄弱环节;其次,研究绝缘材料电导率随温度变化特性对电场分布的影响规律,通过有限元仿真模拟电缆空载和满载运行时附件的温度分布与电场分布,发现最大电场出现在电缆绝缘靠近附件应力锥一侧,为29.5 kV/mm,低于附件材料的击穿场强;最后,研究界面在直流电场下空间电荷特性对电场分布规律的影响,通过电声脉冲法测试复合叠层片状样品介质界面的空间电荷及其电场分布,发现场强畸变率约为100%~200%。同材料本征绝缘匹配相比,界面空间电荷积聚对附件内部电场造成的畸变程度更严重,在后续附件提升中应更注重开发抑制空间电荷的绝缘材料。  相似文献   

2.
交联聚乙烯(XLPE)因其优异的介电、理化性能而被广泛应用于电缆绝缘领域。在电缆的服役过程中,电缆绝缘内部会积聚空间电荷,严重时可引发电场畸变,导致电缆击穿事故发生。对于直流XLPE电缆,空间电荷的积聚及影响更加不容忽视。针对直流XLPE电缆绝缘中产生的空间电荷积聚效应,目前学界主要采用共混改性、聚合物链段接枝极性基团、纳米掺杂改性及制备高纯净绝缘料等方法来进行控制,改性后的直流XLPE电缆绝缘对空间电荷产生的抑制效果均有所提升。文中首先对上述直流XLPE电缆绝缘中空间电荷的抑制方法进行综述,介绍其抑制原理以及相应的抑制效果,然后对比总结不同抑制空间电荷方法的优缺点,最后对未来直流XLPE电缆绝缘中空间电荷抑制方法的研究发展作出展望。  相似文献   

3.
Space charge is believed to play an important role in ac electrical ageing of polymeric insulation, particularly where electrical treeing is the dominant cause of premature failure. The majority of work to date has been on the space charge characteristics under dc electric stresses, whereas work on the dynamics and the role of space charge on electrical breakdown under 50 Hz ac conditions have only received limited attention. Consequently, a full understanding of space charge trapping and dynamics under ac operating conditions is required if ever more reliable polymer insulated cable systems are to be developed. The present paper reports on aspects of an on-going investigation into the measurement of space charge in XLPE insulation under 50 Hz ac stress using the laser induced pressure propagation (LIPP) technique. Some important features of the method are described such as, point on wave control of the laser and use of correction factors to offset variations in the laser power and ablation of the target material. Emphasis has also been placed on establishing a simple method for analysing data, termed "X-plots". Some preliminary results of the space charge and electric stress distribution of un-degassed and degassed crosslinked polyethylene (XLPE) plaques aged electrically under ac stress (30 kVpeak/mm) for 24 h are also presented  相似文献   

4.
In the present work, electrical trees were experimentally generated in virgin and gamma-irradiated XLPE cable insulation, under AC voltages. Fibrillar type of electrical tree structure forms from the defect site in gamma-irradiated specimens. Failure times due to electrical trees were analysed by adopting Weibull distribution studies. The results of the study indicate that gamma-irradiated specimens, where the rate of tree propagation is high, causing early failure of insulation. Pulsed electro acoustic emission (PEAE) technique was adopted to understand the space charge formation in XLPE cable insulation. The results of the study indicate that homo and hetero charges form near to the electrodes especially in gamma-irradiated XLPE cable insulation. Variations in space charge density at different voltage magnitudes with time were analysed. It is observed that the electric field in the insulating material becomes highly non-uniform on occurrence of hetero charges. It is also realized that on removal of applied voltage, the charge decay is less with gamma-irradiated specimens. Based on the present study, it could be concluded that Space charge density in insulating material and life of insulating material due to electrical tree formation shows inverse relationship.  相似文献   

5.
This paper discusses tree inception and breakdown voltage characteristics of XLPE cable insulation subjected to impulse voltages superimposed on ac voltage. The tree initiation tests were performed on laboratory-molded specimens equipped with needle electrodes, whereas the breakdown tests were conducted on a full-sized cable. The impulse tree initiation stress was found to be dependent on the magnitude of the pre-applied ac stress and the relative polarities of the impulse and the ac peak at the instant of their superposition. Although the impulse polarity has an effect on the tree inception, the general behavior is that the tree inception stress always decreases with an increase of the pre-applied ac stress. This phenomenon is discussed in terms of the space charge effect and the influence of the impulse voltage application itself. The impulse strength of a full-sized cable insulation was found to be independent of the pre-applied ac stress as long as that stress did not exceed the operating stress of a 500 kV cable insulation. However, subjecting cable insulation to higher ac stresses before impulse application caused a reduction of its breakdown strength as compared with the insulation without ac prestressing  相似文献   

6.
配网交联聚乙烯(cross linked polyethylene, XLPE)电缆的严重击穿故障大多发生在电缆接头处,主要由电缆接头在制造和安装过程中的工艺缺陷引起。文中采用模拟电荷法研究电缆接头4种典型缺陷,即气隙、水膜、金属碎屑和金属外破附近的电场分布特征;然后采用电场计算与随机漫步理论相结合的方法,分析缺陷引发的电树枝的分布规律。同时,测量带缺陷配网XLPE电缆接头样本周围的实际电场分布,并比较测量结果与计算结果。结果表明,采用电场测量的方法可以直接有效地识别电缆接头内部缺陷类型,相比气隙、水膜缺陷,导电缺陷造成的电场畸变更为显著。缺陷引发的电场畸变大于临界电场值时会引起电树发展,电树发展的轨迹长度与场强大小呈正相关,导电缺陷引发的电树枝有较大概率向缆芯方向发展,更易引起XLPE绝缘击穿。  相似文献   

7.
Charge generation in cross-linked polyethylene (XLPE) and ethylene propylene rubber (EPR) under dc stress are influenced strongly by inclusions. The inclusions influencing charge generation are cross-linking byproducts, antioxidants, and moisture. These inclusions particularly influence the generation of negative heterocharges observed near positive electrodes, which produce high electric stress regions in XLPE cable insulation under dc voltage. Because a high electric field might cause dielectric breakdown of high-voltage equipment, it is important to minimize negative heterocharge accumulation. Consequently, the authors performed experiments to clarify the negative heterocharge generation mechanism in XLPE and EPR. The authors first studied the influence of cross-linking byproduct and moisture on negative heterocharge generation to clarify the mechanism. The authors next performed experiments to elucidate the effect of antioxidants on heterocharge generation, which revealed that the negative heterocharge is generated in XLPE insulation containing sulfur-containing phenolic antioxidant, or sulfur-type antioxidant. This heterocharge is presumed to be created by the combined effect of the antioxidant and acetophenone. Furthermore, the authors studied the dissipation of negative heterocharges in XLPE and EPR, clarifying that the dissipation of negative heterocharges in EPR is much faster than that in XLPE. This paper presents results of these studies.  相似文献   

8.
吕庚民 《电线电缆》2014,(2):6-7,28
超高压交联聚乙烯(XLPE)电缆连接盒是电缆附件中绝缘空间最小、绝缘介质承受电场强度最高、用量最大的电缆附件。提高其绝缘裕度,降低制造成本尤为重要。通过应用ANSYS电磁场分析软件,对现有的超高压XLPE电缆连接盒的整体预制橡胶绝缘体进行电场分析计算。根据计算结果再对其表面电场强度最高的高压屏蔽电极形状进行优化设计。参考空气动力学原理对电极端部形状采用流线型设计,再进行电场分析。综合绝缘裕度和制造成本两方面的因素,确定橡胶预制绝缘体的结构,实现提高绝缘裕度、降低制造成本的目的。  相似文献   

9.
It is well known that the existence and accumulation of space charge in insulation can be harmful to polymer power cable. Although there is much research done on space charge distribution in various samples, there are still some important problems left unsolved, such as the mechanism of formation and elimination of space charge in dielectrics. Because of its superiority, the pulsed electro-acoustic (PEA) measurement method is used widely in the measurement of space charge in various geometries of samples such as the multiple layer plate and cylindrical cables. The space charge in crosslinked polyethylene (XLPE) power cable under dc voltage and heat treatment is investigated by the PEA method in this paper. After heat treatment, the space charge, which previously formed in cable insulation under the applied voltage, disappears. If electrical stress is applied to the insulation again, space charge will appear once more. However, after the cable is heated and degassed in vacuum for a long time, no matter how long the dc voltage is applied to the cable, no more space charge will be formed in the cable. The mechanism of formation and elimination of space charge under the effect of electrical and thermal stress is discussed  相似文献   

10.
交联聚乙烯(XLPE)电缆以其优良的机械和电气性能广泛应用于现代电力系统。研究表明,在直流电压作用下绝缘中容易形成空间电荷,导致电场畸变,加速绝缘老化。国内外很少关于交流电压下空间电荷对XLPE电缆绝缘影响的研究。本文综述了交流电压下空间电荷对XLPE电缆绝缘老化的影响及其作用机理,并介绍了交流电压下测量空间电荷分布的改进的电声脉冲法。结果表明,交流电压下,空间电荷分布特性影响XLPE电缆绝缘老化。  相似文献   

11.
30kV直流XLPE电缆电场及温度场的仿真计算   总被引:1,自引:0,他引:1  
根据电流场和静电场理论,分析了在计算电缆绝缘层电场分布时必须同时考虑电导率和空间电荷的影响。为计算直流交联聚乙烯(XLPE)电缆绝缘层径向电场及温度场分布,应用多物理场有限元仿真软件COMSOL模拟实际运行工况,解决了电热耦合场场量的计算。仿真计算时,电导率模型采用的是最适合XLPE绝缘材料的经验公式;设计阶段的空间电荷数据是采用电声脉冲(PEA)技术测量绝缘样品而得到。仿真计算结果表明,设计的30kV直流XLPE电缆是满足设计和实际运行要求的。  相似文献   

12.
This report deals with space charge behavior in PE (polyethylene) under dc fields. Direct observation of time-dependent space charge profiles in 3-mm thick XLPE (crosslinked low-density polyethylene) cable insulation under dc electric fields was performed using the pulsed electroacoustic method. Stable hetero charges were formed when the field was as low as 0.2 MV/cm, and intermittent generation of packet shaped space charges and their propagation through the insulation were observed when the field was as high as 0.7 MV/cm. These phenomena were reproduced in sheet specimens of XLPE and LDPE (low-density polyethylene). It was found that hetero charges resulted from heat treatment of the XLPE specimen containing antioxidant and acetophenone, which is one of the crosslinking by-products, suggesting dissociation of the antioxidant through solvation at high temperature by acetophenone. The packet charges were easily detected when acetophenone was diffused into the LDPE specimen. However, uniformity of acetophenone distribution prevented the packet charge generation. It is suggested on the basis of several experimental results that local ionization of impurities in the insulation through solvation by acetophenone takes place assisted by high field and leads to the packet charge generation. A numerical simulation was carried out based on the above model  相似文献   

13.
从工程电介质进展看前沿课题   总被引:7,自引:1,他引:7  
叙述工程电介质领域内近几年来取得的进展,重点介绍工程电介质理论的数学基础、固体聚合物绝缘的电击穿理论、纳米电介质、局部放电测量、空间电荷、电缆绕组电力设备、绝缘油、交联聚乙烯电力电缆、超导绝缘、有机电光器件、环境友好绝缘材料、塑料绝缘回收、变频电机绝缘、新材料、陶瓷介质和合成绝缘子方面的研究成果.  相似文献   

14.
The accumulation of space charge in the crosslinked polyethylene (XLPE) insulation of a power cable sample under dc stress was investigated. The sample was held at 82°C and atmospheric pressure, and at 82°C and 0.1 Pa, for periods up to several days. Such conditioning removed pre-existing space charge, When an external dc field was applied after conditioning at atmospheric pressure and 82°C, space charge accumulated at a rate considerably faster than that observed before conditioning. However the rate of accumulation following conditioning at 82°C under reduced pressure was much slower than that observed before conditioning. The faster rate could be recovered by reconditioning the sample at atmospheric pressure after conditioning under reduced pressure. Inversion of the equilibrium space charge profile, following reversal of the applied field, was observed. This observation is consistent with a model incorporating a spatially-inhomogeneous polarization in the amorphous volume of the XLPE, and electron injection/extraction at the electrodes. The electron transfer between electrode and XLPE in either direction involves the same narrow window of combined donor and acceptor states in the insulator, centered on the Fermi level. The spatially-inhomogeneous polarization in the XLPE originates in a spatially-inhomogeneous distribution of dipole complexes. It is suggested that the dipoles are formed by a process equivalent to nonpermanent oxidation of the XLPE, requiring water as a catalyst  相似文献   

15.
Information on space-charge behavior in thick insulated samples aids in understanding the dc characteristics of polymer-insulated dc cables. The pulsed electroacoustic method is used to investigate several space charge formation factors in 2 mm-thick polyethylene (PE). The following results were obtained. For measurement factors: (1) A polymeric semiconducting electrode provides a more accurate measurement than does a metal electrode as a result of better matching of acoustic impedance with PE. (2) Within a dc electrical stress range of several tens kV/mm, the space charge distributions under and after dc voltage application are almost the same; this is due to a comparatively long time of space-charge decay. (3) The space-charge distribution of a plate sample agrees with that of a cable sample having the same insulation thickness. For insulating material factors: (1) The amount of space charge in crosslinked polyethylene (XLPE) is much larger than that in low-density PE (base of XLPE). The space charge of XLPE continues to increase even after dc voltage application (24 h); that of LDPE reaches equilibrium with a few hours. (2) The aforementioned space charge difference between XLPE and LDPE is assumed to be caused by ionic impurities in XLPE, not by the additives themselves (acetophenon and cumylalcohol as byproducts of cross linking and antioxidant).  相似文献   

16.
This paper reports on a study using the laser induced pressure propagation (LIPP) method to measure the space charge characteristics in bulk crosslinked polyethylene (XLPE) insulation under dc electric stress. Particular attention has been given to the quantitative appraisal of calibration parameters, and the resultant estimations of space charge and electric stress distributions. A method is described for analyzing the measured raw data from ramp voltage and aging tests to give an estimate of charge and stress without resorting to a complicated mathematical exercise. The consequence of stress enhancement due to the trapped charge on the life of the insulation is estimated using the empirical inverse law. Using analysis of variance and a multivariate analysis technique, the effects of treatment and type of XLPE on the space charge characteristics are also discussed  相似文献   

17.
Space charge in full size ±250 kV dc cables was measured using a pulse-electroacoustic method. Two newly developed types of dc XLPE cables with 20 mm thick insulation were subjected to measurements at a dc voltage of 500 kV, keeping the conductor temperature either at room temperature or at 85°C. Qualitative analyses of the space charge distribution and the quantitative analysis of the electric fields in the vicinity of semicon interfaces were made. It was shown that the field in the vicinity of the inner semiconductor tends to increase by 10 to 40% when the polarity of the applied voltage was switched, in the case when the conductor was kept at 85°C. However, the distortion of the electric field was significantly smaller than that expected with conventional XLPE cables. As a result, dc cables are considered to have stable dc characteristics from the viewpoint of space charge behavior. © 1998 Scripta Technica, Electr Eng Jpn, 124(2): 16–28, 1998  相似文献   

18.
The presence of space charge changes locally the electric field distribution in power cable insulation and may play an important role in tree development, thus accelerating the dielectric breakdown. This paper is concerned with the computation of the electric field in polyethylene-insulated power cables affected by water trees which grow from the following: 1) the inner semiconducting layer; 2) the outer semiconducting layer; and 3) the inner and outer semiconducting layers, taking into account the space charge corresponding to the ions present in the treeing area. Space charge in plane samples where trees have been developed in an accelerated manner was estimated using the thermal step method. Average charge values given by space charge measurements were then used for the electric field computation in cable insulation with continuous or/and individual water trees. For the calculation of the electric field, an analytical and a numerical method have been used. This paper shows that the space charge changes the electric field distribution inside and outside the trees (the field increases in some areas and decreases in others) and that the field variations depend on the magnitude and on the polarity of the space charge, as well as on the dimensions of the water trees developed in the cable insulation. The obtained results show that, in the presence of water trees and space charge, the initiation of electric trees is more probable in the case of individual water trees than in the case of continuous water trees.  相似文献   

19.
This review summarizes research on treeing phenomena, i.e. the formation of electrical trees and water trees, that has been undertaken in Japan for the development of 500 kV XLPE cable. Section 1 presents the results of factors affecting XLPE cable insulation breakdown under commercial ac and lightning impulse voltages. Section 2 verifies the phenomena of electrical tree formation in XLPE cable insulation using block samples and model cables, and gives the results of studies to determine the level electrical field stress initiation for such trees. Section 3 summarizes the results of studies on long-term aging characteristics, which is a particular problem under commercial ac voltages, while Section 4 explains how this research influenced the design of 500 kV XLPE cable insulation. All authors were members of `The investigation committee of fundamental process of treeing degradation' under IEEJ  相似文献   

20.
张轩  杨延霞 《四川电力技术》2014,37(5):82-85+90
为了研究10 k V XLPE电缆本体受伤电场情况,防止电缆缺陷局部放电电场发展导致电缆接头击穿,通过分析XLPE电缆主要缺陷类型及原因来确定引起电缆故障的主要类型故障,然后利用有限元分析方法对电缆本体受伤情况电场进行仿真研究,最后根据仿真结果得出结论:在电缆本体空洞插入铁丝会造成电场畸变,严重时会造成绝缘击穿,为今后电缆线路故障分析提供参考。  相似文献   