首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Aerobic biological treatment of digested sludge was studied in a continuously operated laboratory set-up. An aerated reactor was filled with thermophilically digested sludge from the Moscow wastewater treatment plant and inoculated with special activated sludge. It was then operated at the chemostat mode at different flow rates. Processes of nitrification and denitrification, as well as dephosphatation, occurred simultaneously during biological aerobic treatment of thermophilically digested sludge. Under optimal conditions, organic matter degradation was 9.6%, the concentrations of ammonium nitrogen and phosphate decreased by 89 and 83%, respectively, while COD decreased by 12%. Dewaterability of digested sludge improved significantly. The processes were found to depend on hydraulic retention time, oxygen regime, and temperature. The optimal conditions were as follows: hydraulic retention time 3-4 days, temperature 30-35 degrees C, dissolved oxygen levels 0.2-0.5 mg/L at continuous aeration or 0.7-1 mg/L at intermittent aeration. Based on these findings, we propose a new combined technology of wastewater sludge treatment. The technology combines two stages: anaerobic digestion followed by aerobic biological treatment of digested sludge. The proposed technology makes it possible to degrade the sludge with conversion of approximately 45% volatile suspended solids to biogas, to improve nitrogen and phosphorus removal in reject water from sludge treatment units, and to achieve removal of malodorous substances after 8-9 days of anaerobic-aerobic sludge treatment.  相似文献   

2.
Winery and distillery wastewater treatment by anaerobic digestion.   总被引:1,自引:0,他引:1  
Anaerobic digestion is widely used for wastewater treatment, especially in the food industries. Generally after the anaerobic treatment there is an aerobic post-treatment in order to return the treated water to nature. Several technologies are applied for winery wastewater treatment. They are using free cells or flocs (anaerobic contact digesters, anaerobic sequencing batch reactors and anaerobic lagoons), anaerobic granules (Upflow Anaerobic Sludge Blanket--UASB), or biofilms on fixed support (anaerobic filter) or on mobile support as with the fluidised bed. Some technologies include two strategies, e.g. a sludge bed with anaerobic filter as in the hybrid digester. With winery wastewaters (as for vinasses from distilleries) the removal yield for anaerobic digestion is very high, up to 90-95% COD removal. The organic loads are between 5 and 15 kgCOD/m3 of digester/day. The biogas production is between 400 and 600 L per kg COD removed with 60 to 70% methane content. For anaerobic and aerobic post-treatment of vinasses in the Cognac region, REVICO company has 99.7% COD removal and the cost is 0.52 Euro/m3 of vinasses.  相似文献   

3.
The versatile metabolism of microorganisms has an played important role in the biodegradation of recalcitrant toxic compounds entering into the natural environment. The biodegradability of organics can be enhanced using bioaugmentation and advanced oxidation processes (AOP) for aerobic/anaerobic treatment programs. Wastewater from a bulk drug (cresol) plant had high levels of TDS, COD and BOD, whilst the levels from a pigment plant low. Both contained organics difficult to degrade. AOP using hydroxyl radical generated in 1 L glass reactor using UV and H2O2 efficiently oxidised phenol and cresol. COD and sulphite reduction in cresol containing wastewater were 20-60% in 1-6 h. A twenty to thirty percent reduction in copper phthalocyanine pigment effluents was achieved in 6 h using AOP. Strains of Micrococcus, Pseudomonas, and Nocardia degrading phenol, cresol were isolated from soil and sludge. Mixed biomass of these organisms removed phenols (1,000 ppm) and cresols (500 ppm) completely in 24 and 72 h, respectively. The COD and BOD reductions under the optimum nutritional and physiological conditions were in the range of 70 to 90%. When added to the bioreactor, 20% of the developed biomass of mixed strains of Micrococcus, Nocardia and Pseudomonas increased the rate of COD and BOD reduction gradually and stabilised at 80-90%. Added biomass improved the overall efficiency of the aerobic process.  相似文献   

4.
The paper will report about the experiences at an Austrian large wastewater treatment plant of 720,000 population equivalents, where anaerobically digested sewage sludge is further stabilised under aerobic conditions. Enhanced stabilisation of the anaerobically digested sludge was required at the plant in order to get a permit for landfill disposal of the dewatered stabilized sludge. By implementing a post-aeration treatment (SRT approximately 6d; 36 degrees C) after anaerobic digestion the organic content of the anaerobically well digested sludge can be decreased by 16%. Investigations on site showed that during digested sludge post-aeration anoxic phases for denitrification are needed to provide stable process conditions. In this way the pH value can be kept in a more favourable range for micro-organisms and concrete structures. Additionally, inhibition of the biological process due to nitrite accumulation can be avoided. By optimising the aeration/pause ratio approximately 45% of total nitrogen in digested sludge can be removed. This significantly improves nitrogen removal efficiency at the wastewater treatment plant. NH(4)-removal occurs mainly through nitritation and denitritation with an efficiency of 98%. The costs/benefit analysis shows that post-aeration of digested sludge results in an increase of total annual costs for wastewater treatment of only 0.84%, corresponding to 0.19 Euro/pe/a. Result of molecular biological analyses (DGGE) indicate that all four ammonium-oxidizing bacteria species present in activated sludge can survive anaerobic digestion, but only two of them can adapt in the digested sludge post-aeration tanks. Additionally, in the post-aerated digested sludge a further ammonium-oxidizing bacteria species was identified.  相似文献   

5.
Anaerobic digestion of residual municipal solid waste (MSW) has become more important than the digestion of source separated biowaste. More than 52% of the capacity available in Europe was designed for digestion of residual municipal waste by the end of 2006, while this was only 13% in 1998. Partial digestion of residual waste organics, by which only a part of the organics is digested, has been implemented to reduce the need for dewatering and subsequent wastewater treatment. The digestate coming from part of the organics is immediately mixed with the non-digested organic fraction. This organic fraction is drier and still contains a lot of energy which can be used to dry the digestate during the aerobic composting of the mixture of digested and undigested organics. Such a MBT-plant has been operating for over a year whereby 2/3 of the organics (including sludge cake) are digested (25,000 t/year) and mixed after digestion with the remaining 1/3 of the organics. Biogas production averages 125.7 Nm2 per ton fed and contained 56.2% of methane. The mixture of digestate and non-digested organics is aerated in tunnels during 4 to 6 weeks. The stabilized end product is landfilled, meeting the stringent German standards for inert landfills. By using a dry fermentation able to produce a digestate at 35% solids, there is no need for dewatering the digestate so that no wastewater is produced.  相似文献   

6.
The potential of anaerobic digestion in ecological and decentralised sanitation has been investigated in this research. Different anaerobic digestion systems were proposed for the treatment of sewage, grey water, black water and faeces. Moreover, mathematical models based on anaerobic digestion model no.1 (ADM1) were developed for determination of a suitable design for each system. For stable performance of an upflow anaerobic sludge blanket (UASB) reactor treating sewage, the model results indicated that optimisation of wastewater conversion to biogas (not COD removal) should be selected for determination of the hydraulic retention time (HRT) of the reactor. For the treatment of sewage or black water in a UASB septic-tank, the model results showed that the sludge removal period was the main parameter for determination of the HRT. At such HRT, both COD removal and wastewater conversion are also optimised. The model results demonstrated that for treatment of faeces in an accumulation (AC) system at temperature > or = 25 degrees C, the filling period of the system should be higher than 60 days. For maximisation of the net biogas production (i.e. reduction of biogas losses as dissolved in the effluent), the separation between grey water, urine and faeces and reduction of water consumption for faeces flushing are required. Furthermore, the faeces and kitchen organic wastes and grey water are digested in, respectively, an AC system and UASB reactor, while the urine is stored.  相似文献   

7.
This study was conducted to evaluate the treatability of OMW (olive mill wastewater) with sewage and sewage sludge, which could supplement nutrients and microbes required for OMW treatment and reduce its possible toxicity. The amount of OMW added to an aeration tank was based on the loading difference between the designed and actual COD loads, while the amount added to anaerobic digestion for energy recovery was determined by CH4 production. The COD removal efficiencies were 70-85% for both systems. Compost of OMW with dried sewage sludge also showed a similar temperature profile without OMW addition. This strongly suggested that OMW can be treated at a sewage plant without pretreatment and the treated effluent can be reused in irrigation for an arid region.  相似文献   

8.
The performance of an anaerobic mesophilic packed bed reactor, with a mixture of GAC and tezontle, followed by an aerobic suspended growth system was studied for the treatment of organic chemical wastewater with a high COD concentration (22-29 g/L). The testing of the anaerobic-aerobic system was conducted in an experimental set-up for almost 2.5 years. Different operational conditions were evaluated. The anaerobic reactor showed performance stability and COD removals higher than 80% were obtained with loads up to 16.6 kg x m(-3) x d(-1). The acclimation of the aerobic biomass to the substrate in the anaerobic effluent was very quick and COD removals higher than 94% were obtained even at high organic loads. The combined anaerobic-aerobic system allowed total COD removals higher than 99.5% and the accomplishment of the discharge requirements of 200 mgCOD/L when the anaerobic reactor was operated with loads of 8-11 kg x m(-3)x d(-1) and the aerobic reactor with 0.33 kg x kg(-1) x d(-1), being the total HRT of 4.4. The average TKN removal in the anaerobic-aerobic system was 97%, the average for the anaerobic reactor being 52% and that one for the aerobic system being 94%.  相似文献   

9.
Batch anaerobic digestion tests of primary sludge and waste activated sludge were conducted for a duration of 123 days to determine the ultimate degradability of the sludges. For primary sludges the inert fraction of the particulate COD that was predicted by the wastewater models could be employed to predict their biodegradability under anaerobic conditions. The degradation of waste activated sludge was adequately characterized for the first 60 days of digestion using a model that assumed equivalent biodegradability of particulate COD components under aerobic and anaerobic conditions. However after 60 days of anaerobic digestion it appeared that decay of the endogenous products was occurring. This could be described with a first order decay function with a coefficient of 0.0075 d(-1). For continuous flow digesters operating at SRTs of 30-60 days, the predicted VSS destruction with the modified model was approximately 10% higher than that predicted on the basis of inert endogenous decay products.  相似文献   

10.
Source-based wastewater characterization and stream segregation provide effective management of industrial wastewaters. The characterization of wastewater sources from a confectionery factory was presented and performance of the wastewater treatment plant was evaluated in this study. All of the wastewater sources in the factory, except the vacuum water line, can be characterized by high concentrations of soluble pollutants and low pH. High organic content of the wastewater generated from the confectionery industry promoted the application of anaerobic technology as a pre-treatment before the conventional aerobic treatment. The average chemical oxygen demand (COD) removal and biogas production for expanded granular sludge bed reactor were 88% and 1,730 Nm(3)/day, respectively. The effluent from the investigated facility can be used for irrigation provided that conductivity values are within acceptable limits.  相似文献   

11.
Further reduction of volatile suspended solids (VSS) during a post-stabilisation step was applied to evaluate the stabilisation degree of digested sewage sludge. For this purpose digested sludge was collected at four municipal wastewater treatment plants (WWTPs) and further stabilised in lab-scale chemostat reactors either under anaerobic or aerobic conditions. Experimental results showed that even in adequately digested sludge a consistent amount of VSS was degraded during aerobic post-stabilisation. It seems that aerobic conditions play a significant role during degradation of residual VSS. Additionally, specific VSS production (gVSS/peCOD110.d) as well as specific oxygen uptake rate were shown to be suitable parameters to assess the degree of sludge stabilisation at WWTPs. Fourier transform infrared spectroscopy was used to reveal changes in the sludge composition. Spectra of treated and untreated sludge samples indicated that the major component of residual VSS in stabilised sludge for instance consisted of biomass, while cellulose was absent.  相似文献   

12.
At a large Austrian municipal wastewater treatment plant enhanced stabilisation of anaerobically digested sewage sludge was required in order to get a permit for landfill disposal of the dewatered stabilized sludge. By implementing a post-aeration treatment after anaerobic digestion the organic content of the anaerobically well digested sludge can be decreased by 16%. Investigations at this plant showed that during digested sludge post-aeration anoxic phases are needed to provide stable process conditions. In this way the pH value can be kept in a more favourable range for micro-organisms and concrete structures. Additionally, under the process conditions applied nitrite accumulation would inhibit the stabilisation process if denitrification is not adequately applied. By optimising the aeration/pause ratio approximately 45% of total nitrogen in digested sludge can be removed. NH4-removal occurs through nitrification and denitrification with an efficiency of 98%. This significantly improves nitrogen removal efficiency at the wastewater treatment plant. The costs/benefit analysis shows that post-aeration of digested sludge results in an increase of total annual costs for wastewater treatment of only 0.84%, corresponding to 0.19 Euro/pe/a. Specific costs for nitrogen removal (0.32 Euro/kgN) are comparable with other biological processes for N-removal in reject water.  相似文献   

13.
For improving sludge digestion and biogas recovery, a new anaerobic digestion process combined with ozonation was tested at a full-scale unit for 2 years and its performance was compared with a simultaneously operated conventional anaerobic digestion process. The new process requires two essential modifications, which includes ozonation for enhancing the biological degradability of sludge organics and concentrating of solids in the digester through a solid/liquid separation for extension of SRT. These modifications resulted in high VSS degradation efficiency of ca. 88%, as much as 1.3 times of methane production and more than 70% reduction in dewatered sludge cake production. Owing to accumulation of inorganic solids in the digested sludge, water content of the dewatered sludge cake also reduced from 80% to 68%. An energy analysis suggested that no supplemental fuel was necessary for the subsequent incineration of the cake from the new process scheme. The process is suitable to apply to a low-loaded anaerobic digestion tank, where power production is used.  相似文献   

14.
采用铁盐沉淀电解生化工艺进行煤气厂洗气废水处理试验。试验结果表明 :废水经铁盐沉淀、电解及水解酸化工序后 ,废水的可生化性显著提高 ,经好氧生化处理后的水质指标符合国家有关排放标准 ,CODCr的总去除率达 89%。  相似文献   

15.
A novel technology suitable for centralised and decentralised wastewater treatment has been developed, extensively tested at laboratory-scale, and trialled at a number of sites for populations ranging from 15 to 400 population equivalents (PE). The two-reactor-tank pumped flow biofilm reactor (PFBR) is characterised by: (i) its simple construction; (ii) its ease of operation and maintenance; (iii) low operating costs; (iv) low sludge production; and (v) comprising no moving parts or compressors, other than hydraulic pumps. By operating the system in a sequencing batch biofilm reactor (SBBR) mode, the following treatment can be achieved: 5-day biochemical oxygen demand (BOD5), chemical oxygen demand (COD) and total suspended solids (TSS) reduction; nitrification and denitrification. During a 100-day full-scale plant study treating municipal wastewater and operating at 165 PE and 200 PE (Experiments 1 and 2, respectively), maximum average removals of 94% BOD5, 86% TSS and 80% ammonium-nitrogen (NH4-N) were achieved. During the latter part of Experiment 2, effluent concentrations averaged: 14 mg BOD5/l; 32 mg COD(filtered)/l; 14 mg TSS/l; 4.4 mg NH4-N/l; and 4.0 mg NO3-N/l (nitrate-nitrogen). The average energy consumption was 0.46-0.63 kWh/m3(treated) or 1.25-1.76 kWh/kg BOD5 removed. No maintenance was required during these experiments. The PFBR technology offers a low energy, minimal maintenance technology for the treatment of municipal wastewater.  相似文献   

16.
From an experimental and theoretical investigation of the continuity of influent inorganic suspended solids (ISS) along the links connecting the primary settling tank (PST), fully aerobic or N removal activated sludge (AS) and anaerobic and aerobic sludge digestion unit operations, it was found that the influent wastewater (fixed) ISS concentration is conserved through primary sludge anaerobic digestion, activated sludge and aerobic digestion unit operations. However, the measured ISS flux at different stages through a series of wastewater treatment plant (WWTP) unit operations is not equal to the influent ISS flux, because the ordinary heterotrophic organisms (OHO) biomass contributes to the ISS flux by differing amounts depending on the active fraction of the VSS solids at that stage.  相似文献   

17.
不同工艺对石油采出废水处理的对比试验   总被引:2,自引:1,他引:1  
采用三种不同的工艺 (隔油 -破乳絮凝 -砂滤、隔油 -水解酸化 -SBR和隔油 -破乳絮凝 -SBR)对某油田采油废水进行了对比性试验研究。试验结果表明 :某油田采油废水经隔油 -破乳絮凝 -SBR处理后 ,COD及BOD去除率分别达到了 95 %和 90 %以上 ,出水指标达到了国家含油废水排放标准和回注水标准 ;经过隔油 -破乳絮凝 -砂滤处理后 ,COD和油去除率分别达到 85 %和95 %以上 ,COD没有达到排放标准 ,油达到了排放标准 ;经隔油 -水解酸化 -SBR工艺处理后 ,COD及BOD去除率分别达到 85 %左右和 90 %以上 ,BOD达到了排放水标准 ,但COD没有达到排放标准 ,仍需后续处理  相似文献   

18.
水解-气浮-曝气生物滤池工艺在印染废水处理中的应用   总被引:15,自引:1,他引:14  
刘建广 《给水排水》2001,27(2):43-45
采用水解 气浮 曝气生物滤池工艺处理印染废水的运行结果表明 :在原废水COD为830mg/L ,色度为 560倍 ,BOD为 2 90mg/L的条件下 ,其去除率分别为 82 % ,94 %和 93% ,出水达标排放。  相似文献   

19.
In order to treat wastewater to a low residual COD-concentration such as 125 mg/L, classical biological treatment is not sufficient for many types of industry. This research focused on the integrated treatment of the wastewater of the paper industry, with a membrane bioreactor (MBR) and an oxidation step. The optimal configuration was examined. Screening tests with different types of oxidation showed that ozonation after biological treatment could reduce the COD with 40% with an ozone dose of 0.4-0.8g O3/g COD. BOD/COD ratio could be increased up to 0.19. Neither combination of ozone with UV and/or hydrogen peroxide nor the process H2O2/UV or (photo-)Fenton reagents gave any improvement in COD reduction or BOD increase, unless the doses were very high. Based on these results, an integrated system MBR-ozonation was designed, with recirculation of MBR effluent over ozonation. This test showed that reduction of COD up to 125 mg/L immediately behind the MBR required a lot of ozone. A technically feasible solution was to discharge the water after an extra ozonation step, which resulted in a high total ozone dosage. The alternative, the consecutive treatment activated sludge-ozonation-activated sludge, did not give a better COD-removal with the same ozone dose as the integrated concept. The economic evaluation proves that the integrated chemical and biological treatment is expensive for the paper industry if a low discharge limit of COD has to be complied with.  相似文献   

20.
During a 16 months period, the characteristics of the wastewaters generated in a Rias Baixas winery (Spain) producing white wine were determined: The characterization study showed that white wine wastewater had an average CODt and TSS values of 7.3 and 5.2 kg/m3, respectively being the ratio wastewater/wine produced of about 1.6-2.0 L/L and the ratio between load pollution and produced wine of 9.7 kg(CODt)/m3(WINE). A strategy for the management of wastes and wastewaters allowed for an important reduction of a 55% of wastewater generation to be achieved. In order to select a suitable technology for the treatment of wastewaters two configurations were tested at pilot scale: i) An Anaerobic Filter (AF) of 430 L followed by an activated sludge unit of 510 L and: ii) one activated sludge unit of 510 L. The results showed that the anaerobic/aerobic configuration was more flexible as it adapted quickly to the different loads and flows produced during the different phases through the year. Besides it allowed higher COD removals (98.5-99.2%) to be achieved and proved to permit a quicker re-start up after starvation periods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号