首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 437 毫秒
1.
The transport of liquid water and gaseous reactants through a gas diffusion layer (GDL) is one of the most important water management issues in a proton exchange membrane fuel cell (PEMFC). In this work, the liquid water breakthrough dynamics, characterized by the capillary pressure and water saturation, across GDLs with and without a microporous layer (MPL) are studied in an ex-situ setup which closely simulates a real fuel cell configuration and operating conditions. The results reveal that recurrent breakthroughs are observed for all of the GDL samples tested, indicating the presence of an intermittent water drainage mechanism in the GDL. This is accounted for by the breakdown and redevelopment of the continuous water paths during water drainage as demonstrated by Haines jumps. For GDL samples without MPL, a dynamic change of breakthrough locations is observed, which originates from the rearrangement of the water configuration in the GDL following the drainage. For GDL samples with MPL, no dynamic change of breakthrough location can be found and the water saturation is significantly lower than the samples without MPL. These results suggest that the MPL not only limits the number of water entry locations into the GDL (such that the water saturation is drastically reduced), but also stabilizes the water paths (or morphology). The effect of MPL on the two-phase flow dynamics in gas channels is also studied with multi-channel flow experiments. The most important result is that GDL without MPL promotes film flow and shifts the slug-to-film flow transition to lower air flow rates, compared with the case of GDL with MPL. This is closely related to the larger number of water breakthrough locations through GDL without MPL, which promotes the formation of water film.  相似文献   

2.
Micro porous layer (MPL) is a carbon layer (~15 μm) that coated on the gas diffusion layer (GDL) to enhance the electrical conduction and membrane hydration of proton exchange membrane fuel cell (PEMFC). However, the liquid transport behavior from MPL to GDL and its impact on water management remain unclear. Thus, a three-dimensional volume of fluid (VOF) model is developed to investigate the effects of MPL crack properties on liquid water saturation, liquid pathway formation, and the two-phase mass transport mechanism in GDL. Firstly, a stochastic orientation method is used to reconstruct the fibrous structure of the GDL. After that, the liquid water saturation calculated from the numerical results agrees well with the experimental data. With considering the full morphology of the overlap between MPL and GDL, it's found that this overlap determines the preferred liquid emerging port of both MPL and GDL. Three crack design shapes in MPL are proposed on the base of the similarity crack formation processes of soil mud. In addition, the effects of crack shape, distance between cracks, and crack number on liquid water transport from MPL to GDL are investigated. It is found that the liquid water saturation of GDL increases with crack number and the distance between cracks, while presents little correlation to the crack shape. Hopefully, these results can help the development of PEMFC models without reconstructing full MPL morphology.  相似文献   

3.
In proton exchange membrane fuel cells (PEMFCs), a hydrophobic micro-porous layer (MPL) is usually placed between the catalyst layer (CL) and the conventional gas diffusion layer (GDL) to relieve the flooding. In this paper, a pore network model is developed to investigate how the MPL structure affects the liquid and oxygen transport properties of the bilayer gas diffusion material (GDM) consisting of fine MPL and coarse GDL. The regular three-dimensional pore network constructed to represent the bilayer GDM are composed of the cubic pores that are connected by the narrow throats of square cross section. Based on this model, the capillary pressure, liquid permeability, and oxygen effective diffusivity as a function of GDM liquid saturation are determined. Parameter studies are performed to elucidate the influences of MPL thickness and of MPL crack width. Also analyzed are the liquid distributions in different structural GDMs at the moment of breakthrough. The results reveal a liquid saturation jump at the MPL/GDL interface in the plain bilayer GDM, but a liquid saturation drop in the defective bilayer GDM.  相似文献   

4.
In this study, the effects of adding a microporous layer (MPL) as well as the impact of its physical properties on polymer electrolyte fuel cell (PEMFC) performance with serpentine flow channels were investigated. In addition, numerical simulations were performed to reveal the effect of relative humidity and operating temperature. It is indicated that adding an extra between the gas diffusion layer (GDL) and catalyst layer (CL), a discontinuity in the liquid saturation shows up at their interface because of differences in the wetting properties of the layers. In addition, results show that a higher MPL porosity causes the liquid water saturation to decrease and the cell performance is improved. A larger MPL thickness reduces the cell performance. The effects of MPL on temperature distribution and thermal transport of the membrane prove that the MPL in addition to being a water management layer also improves the thermal management of the PEMFC.  相似文献   

5.
In proton exchange membrane fuel cell (PEMFC), a hydrophobic micro-porous layer (MPL) is usually placed between catalyst layer (CL) and gas diffusion layer (GDL) to reduce flooding. Recent experimental studies have demonstrated that liquid water saturation in GDL is drastically decreased in the presence of MPL. However, theoretical studies based on traditional continuum two-phase flow models suggest that MPL has no effect on liquid water distribution in GDL. In the present study, a pore network model with invasion percolation algorithm is developed and used to investigate the impacts of the presence of MPL on liquid water distribution in GDL from the viewpoint at the pore level. A uniform pressure and uniform flux boundary conditions are considered for liquid water entering the porous layer in PEMFC. The simulation results reveal that liquid water saturation in GDL is reduced in the presence of MPL, but the reduction depends on the condition of liquid water entering the porous layer in PEMFC.  相似文献   

6.
Flooding of the membrane electrode assembly (MEA) and dehydrating of the polymer electrolyte membrane have been the key problems to be solved for polymer electrolyte membrane fuel cells (PEMFCs). So far, almost no papers published have focused on studies of the liquid water flux through differently structured gas diffusion layers (GDLs). For gas diffusion layers including structures of uniform porosity, changes in porosity (GDL with microporous layer (MPL)) and gradient change porosity, using a one-dimensional model, the liquid saturation distribution is analyzed based on the assumption of a fixed liquid water flux through the GDL. And then the liquid water flux through the GDL is calculated based on the assumption of a fixed liquid saturation difference between the interfaces of the catalyst layer/GDL and the GDL/gas channel. Our results show that under steady-state conditions, the liquid water flux through the GDL increases as contact angle and porosity increase and as the GDL thickness decreases. When a MPL is placed between the catalyst layer and the GDL, the liquid saturation is redistributed across the MPL and GDL. This improves the liquid water draining performance. The liquid water flux through the GDL increases as the MPL porosity increases and the MPL thickness decreases. When the total thickness of the GDL and MPL is kept constant and when the MPL is thinned to 3 μm, the liquid water flux increases considerably, i.e. flooding of MEA is difficult. A GDL with a gradient of porosity is more favorable for liquid water discharge from catalyst layer into the gas channel; for the GDLs with the same equivalent porosity, the larger the gradient is, the more easily the liquid water is discharged. Of the computed cases, a GDL with a linear porosity 0.4x + 0.4 is the best.  相似文献   

7.
Water transport through the gas diffusion media of a proton exchange membrane fuel cell (PEMFC) was investigated with a focus on the role of the microporous layer (MPL) coated on the cathode gas diffusion layer (GDL). The capillary pressure of the MPL and GDL, which plays a significant role in water transport, is derived as a function of liquid saturation using a pore size distribution (PSD) model. PSD functions are derived with parameters that are determined by fitting to the measured total PSD data. Computed relations between capillary pressure and liquid saturation for a GDL and a double-layered GDL (GDL + MPL) show good agreement with the experimental data and proposed empirical functions. To investigate the role of the MPL, the relationship between the water withdrawal pressure and liquid saturation are derived for a double-layered GDL. Water transport rates and cell voltages were obtained for various feed gas humidity using a two-dimensional cell model, and are compared with the experimental results. The calculated results for the net drag with application of the capillary pressure derived from the PSD model show good agreement with the experimental values. Furthermore, the results show that the effect of the MPL on the cell output voltage is significant in the range of high humidity operation.  相似文献   

8.
We have used environmental scanning electron microscope to observe vapor condensation and liquid water morphology and breakthrough in porous layers of polymer electrolyte membrane fuel cell. These suggest presence of large droplets and high liquid saturation at interface of the catalyst layer (CL) and gas diffusion layer (GDL), due to jump in pore size. We develop a model for morphology of liquid phase across multiple porous layers by use of both continuum and breakthrough (percolation) treatments. Using the results of this model we show the liquid morphologies deteriorate the efficiency of electrochemical reactions in CL and increase the water saturation in GDL. Then we show that inserting a microporous layer between CL and GDL reduces both the droplet size and liquid saturation and improves the cell performance.  相似文献   

9.
A similarity model experiment was developed to investigate the liquid water transport in hydrophobic porous layers of polymer electrolyte membrane fuel cells (PEMFCs). The dimensionless numbers in the similarity model experiment were closely matched to those in operating PEMFCs. This allowed the visual inspection of invasion-percolation transport of a non-wetting fluid with active capillary fingering in multiple porous layers, similar to the liquid water transport in porous layers of PEMFCs. The experimental results showed that inserting an intermediate layer between a fine layer and a coarse layer suppresses the capillary fingering of the non-wetting fluid inside the coarse layer. Thus, it could be expected that the steady-state volume of the non-wetting fluid in the multiple porous layers decreases as the thickness of the intermediate layer increases. In fact, this trend was quantitatively verified by measuring the volume of the breakthrough droplets formed by the non-wetting fluid that emerged out of multiple porous layers. In addition, pore network simulations were also conducted to reproduce the observed non-wetting fluid transport in multi-layer porous media, and relatively good agreements between experimental and numerical results were obtained.  相似文献   

10.
In order to investigate the effect of capillary pressure on the transport of liquid water in the cathode gas diffusion layer (GDL) of a polymer electrolyte fuel cell, a one-dimensional steady-state mathematical model was developed, including the effect of temperature on the capillary pressure. Numerical results indicate that the liquid water saturation significantly increases with increases in the operating temperature of the fuel cell. An elevated operating temperature has an undesirable influence on the removal of liquid water inside the GDL. A reported peculiar phenomenon in which the flooding of the fuel cell under a high operating temperature and an over-saturated environment is more serious in a GDL combined with a micro-porous layer (MPL) than in a GDL without an MPL [Lim and Wang, Electrochim. Acta 49 (2004), 4149–4156] is explained based on the present analysis.  相似文献   

11.
Water management in a proton exchange membrane (PEM) fuel cell is one of the critical issues for improving fuel cell performance and durability, and water transport across the gas diffusion layer plays a key role in PEM fuel cell water management. In this work, we investigated the effects of polytetrafluoroethylene (PTFE) content and the application of a micro-porous layer (MPL) in the gas diffusion layer (GDL) on the water transport rate across the GDL. The results show that both PTFE and the MPL play a similar role of restraining water transport. The effects of different carbon loadings in the MPL on water transport were also investigated. The results demonstrate that the higher the carbon loading in the MPL, the more it reduces the water transport rate. Using the given cell hardware and components, the optimized operation conditions can be obtained based on a water balance analysis.  相似文献   

12.
This study applied the pseudo-potential Lattice Boltzmann method (LBM) for investigating liquid water transport in the microporous layer (MPL) and gas diffusion layer (GDL) of polymer electrolyte fuel cell. The MPL and GDL reconstruction is performed by using a stochastic method. Unlike previous studies that examined the GDL as two distinct layers of hydrophilic and hydrophobic, this study considered the wettability heterogeneity. In the present study, some of the carbon fibers in the GDL are randomly considered hydrophilic. Moreover, liquid water transport in the compressed and uncompressed GDL with different hydrophilic fibers percentage are compared. The effect of hydrophilic fibers percentage and the compression ratio of the GDL on the liquid water saturation level, the steady-state time, and the formation and growth of droplets in the gas channel (GC) are investigated. The results indicated that more than 10% of hydrophilicity of the fibers lead to the formation of discontinuous water clusters. This phenomenon increased the steady-state time and water saturation level significantly. The simulation showed that compression increased the number of discontinuous water clusters in the GDL. The obtained results demonstrated that the hydrophilic fibers may have positive or negative effects on water transport in the GDL due to their location. In addition, this study indicated that for 10% of hydrophilic fibers with 10% compression, water saturation level and time required to reach steady-state decreased by 5.2% and 22% respectively compared to purely hydrophobic GDL.  相似文献   

13.
The dynamic behavior of liquid water transport through the gas diffusion layer (GDL) of the proton exchange membrane fuel cell is studied with an ex-situ approach. The liquid water breakthrough pressure is measured in the region between the capillary fingering and the stable displacement on the drainage phase diagram. The variables studied are GDL thickness, PTFE/Nafion content within the GDL, GDL compression, the inclusion of a micro-porous layer (MPL), and different water flow rates through the GDL. The liquid water breakthrough pressure is observed to increase with GDL thickness, GDL compression, and inclusion of the MPL. Furthermore, it has been observed that applying some amount of PTFE to an untreated GDL increases the breakthrough pressure but increasing the amount of PTFE content within the GDL shows minimal impact on the breakthrough pressure. For instance, the mean breakthrough pressures that have been measured for TGP-060 and for untreated (0 wt.% PTFE), 10 wt.% PTFE, and 27 wt.% PTFE were 3589 Pa, 5108 Pa, and 5284 Pa, respectively.  相似文献   

14.
Proton exchange membrane fuel cell (PEMFC) gas diffusion layers (GDLs) play important parts in diffusing gas, discharging liquid water, and conducting electricity, etc. When liquid water is discharged through GDL to gas channel, there will be some pores of GDLs occupied by liquid water. In this study, based on a one-dimensional model, the distribution of liquid water phase saturation is analyzed for different GDL structures including GDL with uniform porosity, GDL with sudden change porosity (GDL with microporous layer (MPL)) and GDL with gradient porosity distribution. The effect on gas diffusion of the changes of porosity and liquid saturation due to water remaining in GDL pores is calculated. The conclusions are that for uniform porosity GDL, the gas diffusion increases with the increase of porosity and contact angle and increases with the decrease of the thickness of GDL; for GDL with MPL, the larger the MPL porosity and the thinner the MPL thickness are, the stronger the gas diffusion is; for gradient change porosity GDL with the same average equivalent porosity, the larger the porosity gradient is, the more easily the gas diffuses. The optimization for GDL gradient structure shows that the GDL with a linear porosity distribution of 0.4x+0.40.4x+0.4 is the best of the computed cases.  相似文献   

15.
It is well known that a micro-porous layer (MPL) plays a crucial role in the water management of polymer electrolyte fuel cells (PEFCs), and thereby, significantly stabilizes and improves cell performance. To ascertain the exact roles of MPLs, a numerical MPL model is developed in this study and incorporated with comprehensive, multi-dimensional, multi-phase fuel-cell models that have been devised earlier. The effects of different porous properties and liquid-entry pressures between an MPL and a gas diffusion layer (GDL) are examined via fully three-dimensional numerical simulations. First, when the differences in pore properties and wettability between the MPL and GDL are taken into account but the difference in the entry pressures is ignored, the numerical MPL model captures a discontinuity in liquid saturation at the GDL|MPL interface. The simulation does not, however, capture the beneficial effects of an MPL on cell performance, predicting even lower performance than in the case of no MPL. On the other hand, when a high liquid-entry pressure in an MPL is additionally considered, the numerical MPL model predicts a liquid-free MPL and successfully demonstrates the phenomenon that the high liquid-entry pressure of the MPL prevents any liquid water from entering the MPL. Consequently, it is found from the simulation results that a liquid-free MPL significantly enhances the back-flow of water across the membrane into the anode, which, in turn, helps to avoid membrane dehydration and alleviate the level of GDL flooding. As a result, the model successfully reports the beneficial effects of MPLs on PEFC performance and predicts higher performance in the presence of MPLs (e.g., an increase of 67 mV at 1.5 A cm−2). This study provides a fundamental explanation of the function of MPLs and quantifies the influence of their porous properties and the liquid-entry pressure on water transport and cell performance.  相似文献   

16.
The gas diffusion layer (GDL) covered with a microporous layer (MPL) is being widely used in proton exchange membrane fuel cells (PEMFCs). However, the effect of MPL on water transport is not so clear as yet; hence, many studies are still being carried out. In this study, the effect of MPL on the performance degradation of PEMFCs is investigated in repetitive freezing conditions. Two kinds of GDL differentiated by the existence of MPL are used in this experiment. Damage on the catalyst layer due to freezing takes place earlier when GDL with MPL is used. More water in the membrane and catalyst layer captured by MPL causes permanent damage on the catalyst layer faster. More detailed information about the degradation is obtained by electrochemical impedance spectroscopy (EIS). From the point of view that MPL reduces the ohmic resistance, it is effective until 40 freezing cycles, but has no more effect thereafter. On the other hand, from the point of view that MPL enhances mass transport, it delays the increase in the mass transport resistance.  相似文献   

17.
The freezing characteristics of supercooled water in a gas diffusion layer (GDL), which are the bases for the cold start-up of proton exchange membrane fuel cells (PEMFCs), were investigated. An experimental apparatus for noncontact temperature measurement and observation systems was developed. GDL and GDL with a microporous layer (MPL) were prepared, and freezing experiments using a water-containing GDL under various cooling rates were performed with variations in polytetrafluoroethylene (PTFE) content and water saturation. Furthermore, based on the experimental results, the freezing initiation probability was theoretically investigated to elucidate the freezing characteristics. Results showed that, with increasing supercooling of water in GDL, the freezing probability of water increased abruptly. The effect of saturation showed a different trend depending on PTFE addition. For the GDL without PTFE, the freezing initiations occurred at approximately 6 °C of supercooling degree, and the probability approached 1.0 at approximately 9.5–11.5 °C, with saturation dependency. In contrast, for both GDL and GDL + MPL containing PTFE, the initiation temperature characteristics were relatively similar, which were approximately 8–12 °C, regardless of the saturation and PTFE content. In these cases, the ice-nucleating activity of water in the GDL was possibly stronger than that in the MPL.  相似文献   

18.
Fuel cell vehicles face complicated road conditions, which may impact on the output performance of fuel cell stacks. In the present study, the water transport in the gas diffusion layer (GDL) of proton exchange membrane fuel cell (PEMFC) under vibration conditions are investigated. A stochastic method is employed to reconstruct the 3-D GDL with experimentally validated varying porosities. The volume of fluid (VOF) method is adopted to investigate the two-phase problems. Sinusoidal vibration source terms are superposed, which can vary with required amplitudes and directions. Over time, the water transport process takes three steps: water intrusion, water accumulation, and water removal. The water intrusion tends to start from the sides of the GDL, then spreads into the central area. Compared with the no-vibration case, the water saturations are higher in both the vertical and horizontal vibration cases. The vibration will enhance the water transport through GDL layers. As such, the higher the vibration amplitude and frequency, the larger the water saturation. Accordingly, the water saturation of the GDL vary sinusoidally over time. The water breakthrough paths are identified and compared during the water removal processes. Vibration in the horizontal direction is much easier to promote the water transport inside a layer compared with vibration in the vertical direction. More substantial water saturation in the GDL layers will restrict the gas transfer paths. Consequently, less oxygen will participate in the reaction, which will further impact on the fuel cell performance.  相似文献   

19.
Using the multiphase lattice Boltzmann method (LBM), the liquid water transport dynamics is simulated in a gas diffusion layer (GDL) of polymer electrolyte membrane fuel cells (PEMFCs). The effect of rib structure on the water invasion process in the micro-porous GDL is explored by comparing the two cases, i.e., with rib and without rib structures. The liquid water distribution and water saturation profile are presented to determine the wetting mechanism in the GDL. The results show that the liquid water transport in the GDL is strongly governed by capillary force and the rib structure plays a significant role on water distribution and water transport behavior in the GDL. Comparison of two cases confirms that the rib structure influences on the location of water breakthrough. The liquid water distribution and water saturation profile indicate that the high resistance force underneath the rib suppresses the growth of water cluster, resulting in the change of flow path. After water breakthrough, the liquid water distribution under the channel has little variation, whereas that under the rib continues to change. The predicted value of effective permeability is in good agreement with Carman-Kozeny correlation and experimental results in the literature. The results suggest that the LBM approach is an effective tool to investigate the water transport behavior in the GDL.  相似文献   

20.
Two-phase transport in the cathode gas diffusion layer (GDL) of a proton exchange membrane fuel cell (PEMFC) is studied with a porosity gradient in the GDL. The porosity gradient is formed by adding micro-porous layers (MPL) with different carbon loadings on the catalyst layer side and on the flow field side. The multiphase mixture model is employed and a direct numerical procedure is used to analyze the profiles of liquid water saturation and oxygen concentration across the GDL as well as the resulting activation and concentration losses. The results show that a gradient in porosity will benefit the removal rate of liquid water and also enhance the transport of oxygen through the cathode GDL. The present study provides a theoretical support for the suggestion that a GDL with porosity gradient will improve the cell performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号