首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this work, an electrochemical sensor based on ordered mesoporous carbon (OMC) for the amperometric detection of isoniazid was developed. OMC was dispersed in a solution of Nafion, and the suspension was modified onto the surface of glassy carbon (GC) electrode. Cyclic voltammetry and amperometry were used to investigate the electrochemical behaviors of isoniazid on Nafion-OMC modified electrode (Nafion-OMC/GC). The results indicate that OMC can facilitate the electrochemical oxidation of isoniazid with a great decrease of overpotential in pH 7.0 phosphate buffer solution. The proposed biosensor provides excellent performance towards the determination of isoniazid with a high sensitivity of 0.031 μA/μM, a low detection limit of 8.4 × 10−8 M and wide linear range from 1.0 × 10−7 M to 3.7 × 10−4 M at +0.20 V vs. Ag/AgCl. The method was successfully applied to the determination of isoniazid tablets with satisfying results. All the results suggest that Nafion-OMC/GC electrode is a potential candidate for a stable and efficient electrochemical sensor to detect isoniazid.  相似文献   

2.
In present paper, the graphene doped carbon paste electrode (CPE) was firstly prepared with the addition of graphene into the carbon paste mixture. Compared with conventional CPE, an improved electrochemical response of graphene doped CPE toward the redox couple of Fe(CN)63−/4− was demonstrated owing to the excellent electrical conductivity of graphene. The graphene doped CPE was further used for the successful determination of ascorbic acid (AA), and it showed an excellent electrocatalytic oxidation activity toward AA with a lower overvoltage, pronounced current response, and good sensitivity. Under the optimized experimental conditions, the proposed electrochemical AA sensor exhibited a rapid response to AA within 5 s and a linear calibration plot ranged from 1.0 × 10−7 to 1.06 × 10−4 M was obtained with a detection limit of 7.0 × 10−8 M.  相似文献   

3.
The electrocatalysis of hydrazine oxidation by poly-ethylenedioxy pyrrole (PEDOP)-coated MWCNTs-palladium nanoparticles [PEDOP/MWCNTs-Pd] was investigated as an electrochemical sensor on the surface of glassy carbon electrode (GCE) in aqueous medium. Electrochemical oxidation of hydrazine in phosphate buffer (pH 7.4) was performed using cyclic voltammetry (CV) and chronoamperometry (CA) methods. Using the proposed electrode, the catalytic oxidation peak current of hydrazine was high and the overpotential of its oxidation decreased. Based on the obtained results, a mechanism for electrooxidation of hydrazine at [PEDOP/MWCNTs-Pd/GCE] demonstrated an irreversible diffusion-controlled electrode process and a four-electron transfer involved in the overall reaction. The experimental results showed that the mediated oxidation peak currents of the hydrazine were linearly dependent on the concentration of hydrazine in the range of 1.0 × 10−7 to 5.0 × 10−3 M. The detection limit (S/N = 3) was found to be 4 × 10−8 M with a fast response time of 10 s.  相似文献   

4.
A simple strategy has been used to covalently modify the glassy carbon spheres with anthraquinone moieties through the diazonium salt reduction. The derivatized glassy carbon spheres were used to modify the basal plane pyrolytic graphite electrode by immobilizing them on its surface and examining its electrochemical behaviour. The composite electrode has been used to detect trace level ammonia in the concentration range 5 × 10−8 to 3 × 10−5 M and it was successfully applied to detect low levels of ammonia present in natural samples like urine and soil.  相似文献   

5.
A new all-solid-state Cd2+-selective electrode with a low detection limit was prepared by using conjugated thiophene oligomer α-sexithiophene (α-6T) as solid contact deposited between an ionophore-doped poly(vinyl chloride) membrane and a gold disc substrate. The electrode exhibited a Nernstian response for Cd2+ ions over a wide concentration range of 10−3-10−7 M with a detection limit as low as 1.3 × 10−8 M. Results showed that the fabricated potentiometric sensor was suitable for use within the pH range of 2.0-9.0 and exhibited good reproducibility for long-term measurements.  相似文献   

6.
Pure diamond-like carbon (DLC) thin films and boron-doped DLC thin films have been deposited on silicon substrates using femtosecond pulsed laser. The amorphous carbon materials (DLC), have been deposited at room temperature by ablating graphite targets with an amplified Ti:sapphire laser of 800 nm wavelength and a pulse duration of 150 fs in high vacuum conditions. Doping with boron has been performed by ablating alternatively graphite and boron targets.In this study, the DLC films were used as working electrodes for the electrochemical detection of trace heavy metals namely, Cd2+, Pb2+, Ni2+ and Hg2+, by using square wave anodic stripping voltammetry (SWASV) technique. Four metals were detected at −1.3 V deposition potential, and 90 s deposition time. The DLC films have been characterized by multiwavelength Raman spectrometry and high resolution scanning electron microscopy. The effect of the boron doping on the electrochemical behavior has been shown. The a-C:B 8%/Si3N4 electrode gives the more sensitive detection. The four metals are detected simultaneously with a detection limit of 1 μg/L or 2 μg/L and a dynamic range from 1 or 2 to 25 μg/L for every metal, as presented in third table of this article. The different sensitivities obtained are 6.2, 20.0, 1.2 and 6.6 μA/ppb or μA μg−1 L for Cd2+, Pb2+, Ni2+ and Hg2+, respectively.  相似文献   

7.
A highly sensitive hydrazine sensor was developed based on the electrodeposition of gold nanoparticles onto the choline film modified glassy carbon electrode (GNPs/Ch/GCE). The electrochemical experiments showed that the GNPs/Ch film exhibited a distinctly higher activity for the electro-oxidation of hydrazine than GNPs with 3.4-fold enhancement of peak current. The kinetic parameters such as the electron transfer coefficient (α) and the rate of electron exchange (k) for the oxidation of hydrazine were determined. The diffusion coefficient (D) of hydrazine in solution was also calculated by chronoamperometry. The sensor exhibited two wide linear ranges of 5.0 × 10−7-5.0 × 10−4 and 5.0 × 10−4-9.3 × 10−3 M with the detection limit of 1.0 × 10−7 M (s/n = 3). The proposed electrode presented excellent operational and storage stability for the determination of hydrazine. Moreover, the sensor showed outstanding sensitivity, selectivity and reproducibility properties. All the results indicated a good potential application of this sensor in the detection of hydrazine.  相似文献   

8.
A highly sensitive electrochemical sensor for the determination of acetaminophen at the multiwalled carbon nanotube-alumina-coated silica (MWCNT-ACS) nanocomposite modified glassy carbon electrode is reported. The morphology of the MWCNT-ACS nanocomposite was characterized by field emission scanning electron microscopy. The electrocatalytic properties of the MWCNT-ACS nanocomposite modified glassy carbon electrode were characterized by cyclic voltammetry and square-wave voltammetry in the presence of acetaminophen. The MWCNT-ACS nanocomposite modified glassy carbon electrode exhibited the abilities to raise the current response and to decrease the electrooxidation potential. In cyclic voltammetric responses, the oxidation peak current of acetaminophen obtained at the MWCNT-ACS modified glassy carbon electrode was 100 times greater than that of bare glassy carbon electrode. The MWCNT-ACS nanocomposite modified glassy carbon electrode for the determination of acetaminophen displayed a sensitivity of 376.5 A M−1 cm−2 and a detection limit of 0.05 μM using square-wave voltammetry. The analytical applicability of the developed method was achieved by analyzing the content of acetaminophen in five commercial drugs without pretreatment.  相似文献   

9.
This paper presents the amperometric biosensor that determines choline and cholinesterase activity using a screen printed graphite electrode. In order to detect H2O2 we have blanket modified the electrode material with manganese dioxide nanoparticles layer. Using layer-by-layer technique on the developed hydrogen peroxide sensitive electrode surface choline oxidase was incorporated into the interpolyelectrolyte nanofilm. Its ability to serve as a detector of choline in bulk analysis and cholinesterase assay was investigated. We examined the interferences from red-ox species and heavy metals in the blood and in the environmental sample matrixes. The sensor exhibited a linear increase of the amperometric signal at the concentration of choline ranging from 1.3 × 10−7 to 1.0 × 10−4 M, with a detection limit (evaluated as 3σ) of 130 nM and a sensitivity of 103 mA M−1 cm−2 under optimized potential applied (480 mV vs. Ag/AgCl). The biosensor retained its activity for more than 10 consecutive measurements and kept 75% of initial activity for three weeks of storage at 4 °C. The R.S.D. was determined as 1.9% for a choline concentration of 10−4 M (n = 10) with a typical response time of about 10 s. The developed choline biosensor was applied for butyrylcholinesterase assay showing a detection limit of 5 pM (3σ). We used the biosensor to develop the cholinesterase inhibitor assay. Detection limit for chlorpyrifos was estimated as 50 pM.  相似文献   

10.
A novel Ni2+ optode was prepared by covalent immobilization of thionine, 3,7-diamine-5-phenothiazoniom thionineacetate, in a transparent agarose membrane. Influences of various experimental parameters on Ni2+ sensing, including the reaction time, the solution pH and the concentration of reagents were investigated. Under the optimized conditions, a linear response was obtained for Ni2+ concentrations ranging from 1.00 × 10−10 to 1.00 × 10−7 mol l−1 with an R2 value of 0.9985. The detection limit (3σ) of the method for Ni2+ was 9.30 × 10−11 mol l−1. The influence of several potentially interfering ions such as Ag+, Hg2+, Cd2+, Zn2+, Pb2+, Cu2+, Mn2+, Co3+, Cr3+, Al3+ and Fe3+ on the determination of Ni2+ was studied and no significant interference was observed. The membrane showed a good durability and short response time with no evidence of reagent leaching. The membrane was successfully applied for the determination of Ni2+ in environmental water samples.  相似文献   

11.
A very sensitive and reversible optical chemical sensor based on dithizone as chromoionophore immobilized within a plasticized carboxylated PVC film for Zn2+ determination is described. At optimum conditions (i.e. pH 5.0), the proposed sensor displays a linear response to Zn2+ over 5.0 × 10−8-5.0 × 10−6 mol L−1 range. This range was improved to 2.5 × 10−8-5.8 × 10−5 mol L−1 range by applying principle component-feed forward artificial neural network with back-propagation training algorithm (PC-ANNB). Detection limit of 8.0 × 10−9 mol L−1 was obtained. The sensor is fully reversible within the dynamic range and the response time (t95%) is approximately 4 min under batch conditions. In addition to its high stability and reproducibility, the sensor shows good selectivity towards Zn2+ ion with respect to common metal cations. The sensor was successfully applied for determination of Zn2+ ion in hair sample.  相似文献   

12.
A label-free DNA biosensor for hybridization detection of short DNA species related to the transgenic plants gene fragment of cauliflower mosaic virus (CaMV) 35S promoter was developed in this paper. The nanocomposite containing chitosan (CS) and mutiwalled carbon nanotubes (MWNTs) was first coated on a glassy carbon electrode. Then a highly reactive dialdehyde reagent of glutaraldehyde (GTD) was applied as an arm linker to covalently graft the 5′-amino modified probe DNA to the CS-MWNTs surface via the facile aldehyde-ammonia condensation reaction. The hybridization capacity of the developed biosensor was monitored with electrochemical impedance spectroscopy (EIS) using [Fe(CN)6]3−/4− as an indicating probe, and the experimental results showed that the biosensor had fast hybridization rate and low background interference. A wide dynamic detection range (1.0 × 10−13-5 × 10−10 M) and a low detection limit (8.5 × 10−14 M) were achieved for the complementary sequence. In addition, the hybridization specificity experiments showed that the sensing system can accurately discriminate complementary sequence from mismatch and noncomplementary sequences.  相似文献   

13.
A biosensor based on the immobilization of lactate oxidase (LOx) on a glassy carbon electrode modified with laponite/chitosan hydrogels for the quantification of l-lactate in alcoholic beverages and dairy products is presented. Ferrocene-methanol (FcMe) is used as artificial mediator. The purpose of this work is to determine the best hydrogel composition from the analytical point of view. The characterization of the hydrogels was carried out by CV, amperometry and EIS. According to permeabilities and charge transfer resistances for ferrocyanide (used as molecular probe) as well as the enzymatic behavior of the enzyme for l-lactate, the best laponite/chitosan mass ratio found was 25/50. The distinct features of the bioelectrode are its long stability, its ability to reject or minimize most interferents including ascorbic acid, and its excellent analytical response, which allowed the reduction of the enzyme content below 0.5 U, for a sensitivity of (0.326 ± 0.003) A cm−2 M−1, with a time response lower than 5 s and a detection limit of (3.8 ± 0.2) × 10−6 M. Our l-lactate biosensor was validated by comparison with a standard spectroscopic method.  相似文献   

14.
A novel nanocomposite, comprising of graphene sheet (GS) and ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate (BMIMPF6), was developed on the glassy carbon electrode (GCE) for the simultaneous determination of hydroquinone and catechol in 0.10 M acetate buffer solution (pH 5.0). At the GS/BMIMPF6/GCE, both hydroquinone and catechol can cause a pair of quasi-reversible and well-defined redox peaks. In comparison with bare GCE and GS modified electrode, GS/BMIMPF6/GCE showed larger peak currents, which was related to the higher specific surface area of graphene and high ionic conductivity of BMIMPF6. Under the optimized condition, the cathodic peak current were linear over ranges from 5.0 × 10−7 M to 5.0 × 10−5 M for hydroquinone and from 5.0 × 10−7 M to 5.0 × 10−5 M for catechol, with the detection limits of 1.0 × 10−8 M and 2.0 × 10−8 M, respectively. The proposed method was successfully applied to the simultaneous determination of hydroquinone and catechol in artificial sample, and the results are satisfactory.  相似文献   

15.
The present work describes the electrocatalytic behavior of phosphotungstate-doped glutaraldehyde-cross-linked poly-l-lysine (PLL-GA-PW) film electrode towards reduction of hydrogen peroxide (H2O2) in acidic medium. The modified electrode was prepared by means of electrostatically trapping the phosphotungstate anion into the cationic PLL-GA coating on glassy carbon electrode. The PLL-GA-PW film electrode showed excellent electrocatalytic activity towards H2O2 reduction in 0.1 M H2SO4. Under the optimized conditions, the electrochemical sensor exhibited a linear response for H2O2 concentration over the range 2.5 × 10−6 to 6.85 × 10−3 M with a sensitivity of 1.69 μA mM−1. The curvature in the calibration curve at high concentration is explained in terms of Michaelis-Menten (MM) saturation kinetics, and the kinetics parameters calculated by three different methods were compared. The PLL-GA-PW film electrode did not respond to potential interferents such as dopamine, ascorbic acid and uric acid. This unique feature of PLL-GA-PW film electrode allowed selective determination of H2O2. Finally, the proposed electrochemical sensor was successfully applied to determine H2O2 in commercially available antiseptic solution and soft-contact lenses cleaning solution and the method has been validated using independent estimation by classical potassium permanganate titration method. Major advantages of the method are simple electrode fabrication, stability and high selectivity towards hydrogen peroxide.  相似文献   

16.
A new acridine fluoroionophore containing two diethanolamine ligands, 4,5-bis(N,N-di (2-hydroxyethyl)iminomethyl)acridine (BHIA), was designed and synthesized based on the fluorophore-spacer-receptor format. And its fluorescent sensing behavior towards metal ions was investigated in buffered aqueous media. The presence of Cd2+ induces the formation of a 1:1 ligand/metal complex at neutral pH, which exhibits enhanced emission at 454 nm. The fluorescence intensity is linear with the Cd2+ concentration in the range of 1.0 × 10−6 to 3.0 × 10−5 M (R = 0.9967). Experimental results show a low interference response towards other metal ions. The selective switch-on fluorescence response of BHIA to Cd2+ makes it suitable for sensing of Cd2+ in aqueous solution. The detection limit is 1.3 × 10−7 M. Moreover, the results indicated that BHIA was a reversible chemosensor for Cd2+, which makes it attractive for sensing applications.  相似文献   

17.
Single-walled carbon nanotubes (SWCNTs) functionalized with carboxylic acid groups were cast to glassy carbon electrode (GCE) to construct a three-dimensional nano-micro structured scaffold. Brilliant cresyl blue (BCB) was electropolymerized on the above-mentioned SWCNTs/GCE using continuous cycling between −0.7 and 0.9 V vs. SCE. PolyBCB yielded on SWCNTs/GCE exhibited the enhanced electrochemical redox behavior compared with that electrogenerated on bare GCE. The apparent surface coverage of PolyBCB obtained by SWCNTs/GCE was at least 10 times higher than that obtained by bare GCE, namely 4.8 × 10−9 and 3.6 × 10−10 mol cm−2. The cyclic voltammograms recorded by PolyBCB/SWCNTs/GCE exhibited well-defined two peaks located at −0.25 V and −0.06 V, respectively, with a surface-controlled mechanism. In addition, morphologies of PolyBCB electrogenerated on GCE and SWCNTS/GCE were characterized by atomic force microscopy. Finally, this proposed PolyBCB/SWCNTs/GCE was used in the construction of the second-generation biosensors to hydrogen peroxide and glucose, with the enhanced analytical performance.  相似文献   

18.
In this work, we demonstrated a sensitive and selective electrochemical sensing protocol for the detection of TNT prepared from alkanethiols self-assembled on AuNPs modified glassy carbon (GC) electrode with preadsorbed templates of TNT. It demonstrated that the 2D molecular imprinting monolayers (MIMs) can provide a better site accessibility and lower mass-transfer resistance, while the AuNPs can enhance electrode conductivity, facilitate the electron transfer and increase the amount of TNT-imprinted sites. The prepared sensor showed not only high selectivity toward TNT in comparison to other similar nitroaromatic compounds (NACs), but also a wide linear range over TNT concentration from 4.0 × 10−8 to 3.2 × 10−6 M with a detection limit of 1.3 × 10−8 M (S/N = 3). Moreover, the imprinted sensor has been applied to the determination of TNT in spiked environmental water samples and shows promise for fast and sensitive measurement of trace levels of TNT in real samples.  相似文献   

19.
A simple and new way to immobilize glucose dehydrogenase (GDH) enzyme onto nile blue (NB) covalently assembled on the surface of functionalized single-walled carbon nanotubes (f-SWCNTs) modified glassy carbon (GC) electrode (GDH/NB/f-SWCNTs/GC electrode) was described. The GDH/NB/f-SWCNTs/GC electrode possesses promising characteristics as glucose sensor; a wide linear dynamic range of 100-1700 μM, low detection limit of 0.3 μM, fast response time (1-2 s), high sensitivity (14 μA cm−2 mM−1), anti-interference ability and anti-fouling. Moreover, the performance of the GDH/NB/f-SWCNTs/GC bioanode was successfully tested in a glucose/O2 biofuel cell. The maximum power density delivered by the assembled glucose/O2 biofuel cell could reach 32.0 μW cm−2 at a cell voltage of 0.35 V with 40 mM glucose. The present procedure can be applied for preparing a potential platform to immobilize different enzymes for various bioelectrochemical applications.  相似文献   

20.
An amperometric oxalate biosensor using nanohybrid film of multi-walled carbon nanotubes (MWCNTs) and gold colloidal nanoparticles (GNPs) via carbodiimide chemistry by forming amide linkages between carboxylic acid groups on the CNTs and amine residues of cysteamine self-assembled monolayer (SAM) has been prepared. The c-MWCNTs were immobilized on the gold (Au) electrode and characterized by FTIR. The morphologies of the c-MWCNT/Au and GNPs/MWCNT/Au electrodes were investigated by scanning electron microscopy (SEM) and the electrochemical performance of the Au, c-MWCNT/Au and GNPs/c-MWCNT/Au electrodes were also studied amperometrically. The Cl and NO3 insensitive oxalate oxidase from grain sorghum was finally immobilized on this electrode. The influence of pH, temperature and oxalate concentration on electrode activity was studied. The electrode showed optimum response within 7 s. The electrocatalytic response showed a linear dependence on the oxalic acid concentration ranging from 1 to 800 μM with a detection limit of 1 μM. The Km value for the oxalic acid sensor was 444.44 μM. The enzyme electrode retained 30% of its initial activity after 5 months, when stored at 4 °C. The electrode was employed for measurement of oxalic acid in serum, urine and foodstuffs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号