共查询到18条相似文献,搜索用时 78 毫秒
1.
采用微波消解-原子荧光光谱法同时测定蔬菜中的砷和汞,结果表明:砷、汞标准溶液浓度分别在0~32μg/L、0~3.2μg/L范围内线性良好;砷、汞检出限分别为0.13μg/L、0.10μg/L;砷、汞样品加标回收率分别在95.5%~99.6%、77.0%~110.8%之间;该法操作简便,重现性较好,能满足蔬菜中砷和汞的测定要求。 相似文献
2.
微波消解——原子荧光光谱法同时测定有机-无机复混肥料中砷和汞的含量 总被引:1,自引:0,他引:1
采用微波消解样品预处理技术和原子荧光光谱法同时测定有机-无机复混肥料中的砷和汞,确定微波消解样品的条件,优化仪器的最佳工作参数。砷和汞的含量分别在0~20μg/L和0~10μg/L范围内有良好线性关系,砷和汞的回收率分别在99.1%~102.0%和98.1%~101.5%,砷和汞的检出限(3σ)分别为0.20μg/L和0.070μg/L。实验表明,该方法具有操作简单、快速、灵敏度高等优点,可适用于有机-无机复混肥料中砷和汞的同时测定。 相似文献
3.
《广州化工》2016,(2)
建立了AFS-830型原子荧光光度计同时测定大米粉中痕量砷、汞的方法,用电热板加热,硝酸-硫酸混合酸一次消解大米粉,用5%的盐酸作载流,20 g/L硼氢化钾和5 g/L氢氧化钾作还原剂进行测定。结果表明:砷、汞的标准溶液浓度在0~10μg/L、0~1.0μg/L范围内线性良好,相关系数分别为0.9998、0.9999;砷和汞的检出限分别为0.046μg/L、0.005μg/L,相对标准偏差RSD(n=6)分别为2.89%~4.21%、2.95%~4.27%,砷和汞的样品加标回收率分别为91.3%~104.4%、93.9%~98.5%。该法快捷简单,检出限低、准确度高、精密度高和重现性良好,能够满足大米粉中砷、汞的测定要求。 相似文献
4.
5.
建立了一种原子荧光法测定化妆品中砷和汞的方法,采用正交设计方法对分析条件进行优化,获得最佳测定条件组合,确定影响分析测试准确度的主要因素,以提高方法准确度、灵敏度。砷和汞分别在0~150μg/L和0~2.0μg/L范围有好的线性关系,检出限分别为0.12μg/L和0.016μg/L,回收率在95.1%~104%,RSD为1.02%~2.46%。结果显示,该方法准确性好,精密度高,操作简便,适合大批量样品的测定。并将该方法应用到实际样品中,结果均满足化妆品的卫生化学指标要求。 相似文献
6.
农产品产地土壤经王水水浴直接消解,硫脲和抗坏血酸作为还原剂,采用氢化物发生原子荧光光谱法双道同时测定砷、汞元素。结果表明,砷、汞元素校正曲线相关系数分别为0.9997和0.9999。方法检出限砷0.010μg/g,汞0.002μg/g。加标回收率砷为97.7%~101.4%,汞为97.3%~99.2%。 相似文献
7.
8.
9.
10.
建立了微波消解原子荧光光谱法同时测定龟苓膏粉中砷和汞含量的方法。优化了检测条件,砷和汞的回收率分别为95.0~99.2%和99.0~104.2%,砷和汞的检出限分别为0.067μg/L和0.013μg/L。该检测方法简便、快捷、灵敏,可同时检测龟苓膏粉中砷和汞。 相似文献
11.
微波消解-原子荧光法同时测定食用菌中砷和汞 总被引:1,自引:0,他引:1
采用微波消解仪处理样品,原子荧光光谱法同时测定食用菌中砷和汞。结果表明:砷在1.0~10.0μg·L-1内线性良好,相关系数为0.9997,汞在0.10~1.00μg·L-1内线性良好,相关系数为0.9990,砷和汞的检出限分别为0.052μg·L-1和0.0087μg·L-1,回收率分别为92.0%和90.0%,相对标准偏差均小于5%。该方法简便、快速、结果准确可靠,能满足食用菌中砷汞的同时测定。 相似文献
12.
13.
Effect of operating conditions in removal of arsenic from water by nanofiltration membrane 总被引:2,自引:0,他引:2
The removal of arsenic from synthetic waters and surface water by nanofiltration (NF) membrane was investigated. In synthetic solutions, arsenic rejection experiments included variation of arsenic retentate concentration, transmembrane pressure, crossflow velocity and temperature. Arsenic rejection increased with arsenic retentate concentration. Arsenic was removed 93-99% from synthetic feed waters containing between 100 and 382 μg/L as V, resulting in permeate arsenic concentrations of about 5 μg/L. Under studied conditions, arsenic rejection was independent of transmembrane pressure, crossflow velocity and temperature. In surface water, the mean rejection of As V was 95% while the rejection of sulfate was 97%. The co-occurrence of dissolved inorganics does not significantly influence arsenic rejection. The mean concentration of As in collected permeated was 8 μg/L. The mean rejection of TDS, total hardness and conductivity were 75, 88 and 75% respectively. 相似文献
14.
15.
16.
对高浓度含砷、铊的黄金冶炼酸性废水进行了氧化-二段混凝沉淀-絮凝处理研究,考察了氧化剂、混凝剂用量和pH值对去除效果的影响。最佳工艺参数为:30%H2O21.5 g/L、FeSO4·7H2O 4.5 g/L、FeCl33.75 mg/L、PAM 15.625 mg/L,pH=6~7。在最佳工艺条件下,砷浓度从298 mg/L降至0.013 2 mg/L,铊浓度从9μg/L降至0.021 9μg/L。处理后废水中砷浓度可达到GB3838-2002《地表水环境质量标准》III类标准,铊浓度可达到GB5749-2006《生活饮用水卫生标准》。 相似文献
17.
将薄层大面积玻碳电解池与小面积玻碳电解池以串联方式连接,在程控状态下使用.铅离子首先在大面积玻碳汞膜电极(LGCE)上预富集,溶出后在小面积玻碳汞膜电极(SGCE)上两次富集,因此提升了SGCE富集效率.测量25 0μg/L铅标准溶液,峰高的相对标准偏差RSD=1.2%.测量铅含量为25.6 μg/L的尿样,测得值27.4μg/L,相对标准偏差RSD=2 3%.富集时间400 s检出限为0.008 8 μg/L;定量检测限为0.029 2 μg/L.与常规的溶出分析比较,检出限降低11 90倍,显著提高检测的灵敏度.流动式电解池在溶出时的底液中不含样品基体. 相似文献