首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Desorption atmospheric pressure photoionization   总被引:3,自引:0,他引:3  
An ambient ionization technique for mass spectrometry, desorption atmospheric pressure photoionization (DAPPI), is presented, and its application to the rapid analysis of compounds of various polarities on surfaces is demonstrated. The DAPPI technique relies on a heated nebulizer microchip delivering a heated jet of vaporized solvent, e.g., toluene, and a photoionization lamp emitting 10-eV photons. The solvent jet is directed toward sample spots on a surface, causing the desorption of analytes from the surface. The photons emitted by the lamp ionize the analytes, which are then directed into the mass spectrometer. The limits of detection obtained with DAPPI were in the range of 56-670 fmol. Also, the direct analysis of pharmaceuticals from a tablet surface was successfully demonstrated. A comparison of the performance of DAPPI with that of the popular desorption electrospray ionization method was done with four standard compounds. DAPPI was shown to be equally or more sensitive especially in the case of less polar analytes.  相似文献   

2.
We present atmospheric pressure laser-induced acoustic desorption chemical ionization (AP/LIAD-CI) with O(2) carrier/reagent gas as a powerful new approach for the analysis of saturated hydrocarbon mixtures. Nonthermal sample vaporization with subsequent chemical ionization generates abundant ion signals for straight-chain, branched, and cycloalkanes with minimal or no fragmentation. [M - H](+) is the dominant species for straight-chain and branched alkanes. For cycloalkanes, M(+?) species dominate the mass spectrum at lower capillary temperature (<100 °C) and [M - H](+) at higher temperature (>200 °C). The mass spectrum for a straight-chain alkane mixture (C(21)-C(40)) shows comparable ionization efficiency for all components. AP/LIAD-CI produces molecular weight distributions similar to those for gel permeation chromatography for polyethylene polymers, Polywax 500 and Polywax 655. Coupling of the technique to Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) for the analysis of complex hydrocarbon mixtures provides unparalleled mass resolution and accuracy to facilitate unambiguous elemental composition assignments, e.g., 1754 peaks (rms error = 175 ppb) corresponding to a paraffin series (C(12)-C(49), double-bond equivalents, DBE = 0) and higher DBE series corresponding to cycloparaffins containing one to eight rings. Isoabundance-contoured plots of DBE versus carbon number highlight steranes (DBE = 4) of carbon number C(27)-C(30) and hopanes of C(29)-C(35) (DBE = 5), with sterane-to-hopane ratio in good agreement with field ionization (FI) mass spectrometry analysis, but performed at atmospheric pressure. The overall speciation of nonpolar, aliphatic hydrocarbon base oil species offers a promising diagnostic probe to characterize crude oil and its products.  相似文献   

3.
The factors influencing desorption and ionization in newly developed desorption atmospheric pressure photoionization-mass spectrometry (DAPPI-MS) were studied. Redirecting the DAPPI spray was observed to further improve the versatility of the technique: for dilute samples, parallel spray with increased analyte signal was found to be the best suited, while for more concentrated samples, the orthogonal spray with less risk for contamination is recommended. The suitability of various spray solvents and sampling surface materials was tested for a variety of analytes with different polarities and molecular weights. As in atmospheric pressure photoionization, the analytes formed [M + H](+), [M - H](-), M(+*), M(-*), [M - H + O](-), or [M - 2H + 2O](-) ions depending on the analyte, spray solvent, and ionization mode. In positive ion mode, anisole and toluene as spray solvents promoted the formation of M(+*) ions and were therefore best suited for the analysis of nonpolar compounds (anthracene, benzo[a]pyrene, and tetracyclone). Acetone and hexane were optimal spray solvents for polar compounds (MDMA, testosterone, and verapamil) since they produced intensive [M + H](+) ion peaks of the analytes. In negative ion mode, the type of spray solvent affected the signal intensity, but not the ion composition. M(-*) ions were formed from 1,4-dinitrobenzene, and [M - H + O](-) and [M - 2H + 2O](-) ions from 1,4-naphthoquinone, whereas acidic compounds (naphthoic acid and paracetamol) formed [M - H](-) ions. The tested sampling surfaces included various materials with different thermal conductivities. The materials with low thermal conductivity, i.e., polymers like poly(methyl methacrylate) and poly(tetrafluoroethylene) (Teflon) were found to be the best, since they enable localized heating of the sampling surface, which was found to be essential for efficient analyte desorption. Nevertheless, the sampling surface material did not affect the ionization mechanisms.  相似文献   

4.
Ultrahigh-resolution electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry has resolved and identified the elemental compositions of over 10000 organic constituents of coal and petroleum crude oil. A plot of Kendrick mass defect versus Kendrick nominal mass sorts compounds into homologous series according to compound class (i.e., numbers of N, O, and S heteroatoms), type (number of rings plus double bonds), and degree of alkylation (number of CH(2) groups), to yield unique elemental assignments from ultrahigh-resolution mass measurements in the 200-900 Da range. Interpretation of such a vast compilation requires a simple (preferably graphical) means to differentiate between complex organic mixtures of different origin or processing. In an extension of the recently revived van Krevelen plot, each elemental composition is projected onto two or three axes according to its H/C, O/C, and/or N/C atomic ratios. The H/C ratio separates compounds according to degree of saturation, whereas O/C or N/C ratios separate according to O and N classes. We show that the three-dimensional van Krevelen diagram can completely separate different classes in pyridine-extracted coal or petroleum samples and can also graphically distinguish fossil fuels according to their nature (coal vs petroleum), maturation (coals of different rank), and processing (the same coal at two stages of liquefaction). The van Krevelen diagram thus appears well suited to amplifying and exposing compositional differences within and between complex organic mixtures.  相似文献   

5.
A new method, photoionization aerosol mass spectrometry (PIAMS), is described for real-time analysis of organic components in airborne particles below approximately 300 nm in diameter. Particles are focused through an aerodynamic lens assembly into the mass spectrometer where they are collected on a probe in the source region. After a sufficient amount of sample has been collected, the probe is irradiated with a pulsed infrared laser beam to vaporize organic components, which are then softly ionized with coherent vacuum ultraviolet radiation at 118 nm (10.5 eV). Since the photon energy is close to the ionization energies of most organic compounds, fragmentation is minimized. Both aliphatic and aromatic compounds of atmospheric relevance are detected and quantified in the low- to midpicogram range. The photoionization signal intensity increases linearly with the amount of material sampled and is independent of particle size. The fragmentation induced by laser desorption is greater than that observed with thermal vaporization, suggesting that the internal energy imparted by the former is greater. Although some molecular fragmentation is observed, mass spectra from common sources of ambient organic aerosol are distinguishable and consistent with previous off-line measurements by gas chromatography/mass spectrometry. These results illustrate the potential of PIAMS for molecular characterization of organic aerosols in ambient and smog chamber measurements.  相似文献   

6.
Humic acids (HAs) were isolated at different stages of composting from two piles of solid olive mill residues (SOR) treated for the first 30 days with tap water (pile C1) or olive mill wastewater (pile C2), for a total composting period of 9 months. The HA fractions were characterized by elemental analysis, UV-visible, Fourier transform infrared and fluorescence spectroscopy in order to monitor humification process and the maturity of the composts. As composting proceeded, the elemental composition of the humic acids showed a decrease in C and H content, and in the C/N ratio, and an increase in N and O contents and in the C/H and O/C ratios. These changes could be attributed to a loss of aliphatic groups and to an increase of aromatic character, polycondensation and degree of oxidation of the HAs. Spectroscopic data agree and support these results, suggesting that the chemical and structural features of the HAs of both composts tend to reach those typical of native soil HAs, that is compounds with a high degree of humification and a high molecular weight and complexity. Therefore, both composting processes seem suitable to produce well-humified organic matter, with important benefits for their use in soil amendment. No differences appeared between the two treatments concerning the humic character of the two final composts.  相似文献   

7.
We present a new elemental analysis (EA) technique for organic species (CHNO) that allows fast on-line analysis (10 s) and reduces the required sample size to approximately 1 ng, approximately 6 orders of magnitude less than standard techniques. The composition of the analyzed samples is approximated by the average elemental composition of the ions from high-resolution electron ionization (EI) mass spectra. EA of organic species can be performed on organic/inorganic mixtures. Elemental ratios for the total organic mass, such as oxygen/carbon (O/C), hydrogen/carbon (H/C), and nitrogen/carbon (N/C), in addition to the organic mass to organic carbon ratio (OM/OC), can be determined. As deviations between the molecular and the ionic composition can appear due to chemical influences on the ion fragmentation processes, the method was evaluated and calibrated using spectra from 20 compounds from the NIST database and from 35 laboratory standards sampled with the high-resolution time-of-flight aerosol mass spectrometer (HR-ToF-AMS). The analysis of AMS (NIST) spectra indicates that quantification of O/C is possible with an error (average absolute value of the relative error) of 30% (17%) for individual species. Precision is much better than accuracy at +/-5% in the absence of air for AMS data. AMS OM/OC has an average error of 5%. Additional calibration is recommended for types of species very different from those analyzed here. EA was applied to organic mixtures and ambient aerosols (sampled at 20 s from aircraft). The technique is also applicable to other EI-HRMS measurements such as direct injection MS.  相似文献   

8.
The molecular formulas for the structures and substructures of muraymycin antibiotics A1 (C52H90N14O19, MW 1214) and B1 (C49H83N11O18, MW 1113) were determined using electrospray ionization (ESI) Fourier transform mass spectrometry (FTMS). The muraymycin A1 and B1 structures were elucidated by utilizing capillary-skimmer fragmentation with up to five stages of mass spectrometry (MS5). Multi-CHEF, a multiple ion isolation method, was used at each stage of MS(n) to isolate a parent ion and up to four reference ions, for exact-mass calibration. The parent ions were fragmented by SORI-CID and the product ions internally calibrated with average absolute mass errors less than 1 ppm at each stage in the fragmentation processes. Using the top-down/bottom-up approach, the molecular formulas for the antibiotics were determined by summing the elemental formulas of the neutral losses, obtained by measuring the mass differences (<500 Da) between the genetically related sequential parent ion masses in the MS(n) spectra, with the unique elemental formula of the lowest parent ion mass (<500 Da). The structures of 12 additional compounds in the muraymycin complex were elucidated using HPLC ESI capillary-skimmer CID FTMS by correlating their fragmentation patterns with those of muraymycins A1 and B1. Sequential neutral losses of an aminosugar, a valine, a uridine, and an ester fatty acid from the muraymycin parent ions provided diagnostic fragments for characterization.  相似文献   

9.
Commercial explosives are complex mixtures that contain not only the active explosive agent(s) but also a host of other organic and inorganic compounds. The ultrahigh mass resolving power (m/delta m50% >200,000) and mass accuracy (<1 ppm) of electrospray ionization Fourier transform ion cyclotron resonance (ESI FTICR) mass spectrometry allow for definitive identification of various species in TNT, RDX, and HMX. We are thereby able to correct prior misassignments of the elemental compositions of the most abundant negative ions from electrospray of RDX and HMX. Although the (known) active agents of many explosives may be identified by low-resolution MS or MS/MS, it is the other characteristic components (indigenous or artificial additives) whose presence and elemental composition can potentially identify the source of the product. ESI FTICR mass spectrometry of smokeless powder, TNT, and Powermite resolves and identifies numerous nonactive ingredients, many of which are recovered in a postblast residue. In contrast, the residue recovered from an explosion of military C4 yielded several species derived from RDX but virtually none from other ingredients.  相似文献   

10.
Zhou X  Shi Q  Zhang Y  Zhao S  Zhang R  Chung KH  Xu C 《Analytical chemistry》2012,84(7):3192-3199
A novel technique was developed for characterization of saturated hydrocarbons. Linear alkanes were selectively oxidized to ketones by ruthenium ion catalyzed oxidation (RICO). Branched and cyclic alkanes were oxidized to alcohols and ketones. The ketones were then reduced to alcohols by lithium aluminum hydride (LiAlH(4)). The monohydric alcohols (O(1)) in the products obtained from the RICO and RICO-LiAlH(4) reduction reactions were characterized using negative-ion electrospray ionization (ESI) Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) for identification of iso-paraffins, acyclic paraffins and cyclic paraffins. Various model saturated compounds were used to determine the RICO reaction and ionization selectivity. The results from the FTICR MS analysis on the petroleum distillates derived saturated fraction were in agreement with those from field ionization gas chromatography time-of-flight mass spectrometry (FI GC-TOF MS) analysis. The technique was also used to characterize a petroleum vacuum residue (VR) derived saturates. The results showed that the saturated molecules in the VR contained up to 11 cyclic rings, and the maximum carbon number was up to 92.  相似文献   

11.
Methods are being developed for ultrasensitive protein characterization based upon electrospray ionization (ESI) with Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). The sensitivity of a FTICR mass spectrometer equipped with an ESI source depends on the overall ion transmission, which combines the probability of ionization, transmission efficiency, and ion trapping in the FTICR cell. Our developments implemented in a 3.5 tesla FTICR mass spectrometer include introduction and optimization of a newly designed electrodynamic ion funnel in the ESI interface, improving the ion beam characteristics in a quadrupole-electrostatic ion guide interface, and modification of the electrostatic ion guide. These developments provide a detection limit of approximately 30 zmol (approximately 18,000 molecules) for proteins with molecular weights ranging from 8 to 20 kDa.  相似文献   

12.
The advent of ultra-high-resolution mass spectrometry has revolutionized the ability of aquatic biogeochemists to examine molecular-level components of complex mixtures of organic matter. The ability to accurately assess the chemical composition, elemental formulas, or both of detected compounds is critical to these studies. Here we build on previous work that uses functional group relationships between compounds to extend elemental formulas of low molecular weight compounds to those of higher molecular weight. We propose an automated compound identification algorithm (CIA) for the analysis of ultra-high-resolution mass spectra of natural organic matter acquired by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. This approach is benchmarked with synthetic data sets of compounds cited in the literature. The sensitivity of our results is examined for different sources of error, and CIA is applied to two previously published data sets. We find that CIA works well for data sets with high mass accuracy (<1 ppm) and can accurately determine the elemental formulas for >95% of all compounds composed of C, H, O, and N. Data with lower mass accuracy must be accompanied with additional knowledge of chemical structure, composition, or both in order to yield accurate elemental formulas.  相似文献   

13.
We report a first attempt to use the laser multiphoton ionization method for analysis of trace aromatic compounds on the surface of environmental (soils) and artificial (silica) samples. The measurement setup is composed of a N(2) pulsed laser and a fast conductivity detection system. The technique has been tested for detection of pyrene deposited on moist fine-powdered samples. The observed photoionization signals have indicated a gradual increase in the photoionization current and charge as a function of increasing concentration of pyrene/hexane solutions used for sample contamination. Contaminants have been analyzed in several (organic and inorganic) environmental samples, and a method to compensate for matrix effects is suggested. A contamination model is assumed and applied in order to renormalize all signals and provide an useful calibration plot. This calibration plot provides an upper estimate of pyrene LOD as 35 ng/g.  相似文献   

14.
Complex natural organic mixtures such as petroleum require ultrahigh mass spectral resolution to separate and identify thousands of elemental compositions. Here, we incorporate a custom-built, voltage-compensated ICR cell for Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS), based on a prior design by Tolmachev to produce optimal mass resolution. The compensated ICR cell installed in a custom-built 9.4 T FTICR mass spectrometer consists of seven cylindrical segments with axial proportions designed to generate a dc trapping potential that approaches an ideal three-dimensional axial quadrupolar potential. However, the empirically optimized compensation voltages do not correspond to the most quadrupolar trapping field. The compensation electrodes minimize variation in the reduced cyclotron frequency by balancing imperfections in the magnetic and electric field. The optimized voltages applied to compensation electrodes preserve ion cloud coherence for longer transient duration by approximately a factor of 2, enabling separation and identification of isobaric species (compounds with the same nominal mass but different exact mass) common in petroleum, such as C(3) vs SH(4) (separated by 3.4 mDa) and SH(3)(13)C vs (12)C(4) (separated by 1.1 mDa). The improved performance of the ICR cell provides more symmetric peak shape and better mass measurement accuracy. A positive ion atmospheric pressure photoionization (APPI) petroleum spectrum yields more than 26,000 assigned peaks, Fourier-limited resolving power of 800,000 at m/z 500 (6.6 s transient duration), and 124 part per billion root mean square (rms) error. The tunability of the compensation electrodes is critical for optimal performance.  相似文献   

15.
Vacuum ultraviolet single-photon ionization time-of-flight mass spectrometry (VUV-SPI-TOFMS) has been applied to the detection of volatile organic compounds (VOCs), including aromatic, chlorinated, and oxygenated compounds. Photoionization mass spectra of 23 VOCs were measured using SPI-TOFMS at 10.5 eV (118 nm). The limits of detection of VOCs using SPI-TOFMS at 10.5 eV were estimated to be a few ppbv. The mass spectra of 20 VOCs exhibit only the parent ion and its isotopes' signals. The ionization processes of the VOCs were discussed on the basis of the reaction enthalpies predicted by the quantum chemical calculations. Absolute photoionization cross-sections for 23 VOCs, including 12 newly measured VOCs, at 10.5 eV were determined in comparison to the reported absolute photoionization cross-section of NO.  相似文献   

16.
In this paper, a simple procedure is introduced for a quick and reliable estimation of detonation heats of aromatic energetic compounds without considering heats of formation of energetic compounds. This method does not use any experimental or computed data of energetic materials. The methodology assumes that the heat of detonation of an energetic compound with composition of C(a)H(b)N(c)O(d) can be obtained from the number of nitrogens, ratios of oxygen to carbon and hydrogen to oxygen as well as the contribution of some specific functional groups. There is no need to use any assumed decomposition products to calculate heats of detonation for energetic compounds. Predicted heats of detonation of pure energetic compounds with the product H(2)O in the liquid state for 31 aromatic energetic compounds have a root mean square (rms) of deviation of 0.32 kJ/g from experiment. The new method gives good results with respect to two empirical methods which use measured heats of formation of explosives with two sets of decomposition gases.  相似文献   

17.
Electrospray ionization broadband FTICR mass spectrometry at a mass resolving power, m/delta m50% > or = 400,000 has achieved the first direct mass spectral resolution of phosphorylated and sulfated peptides (or nucleotides) of the same nominal mass. The elemental composition difference in each case is PH versus S (9.5 mDa), requiring a minimum mass resolving power ((m2 - m1)/ml) of 118,000 (C terminal amidated cholecystekinin fragment 26-33 (CCK-8), DY(PO3H2)MGWMDF-NH2 versus DY(SO3H)MGWMDF-NH2) or 65,400 (adenosine triphosphate vs 3-phosphoadenosine 5'-phosphosulfate). The isobaric mass doublets were detected in broadband mode (400 < m/z <1400) in the presence of dozens of other species. It is therefore now possible to distinguish phosphorylated from sulfated peptides, even when both species are present at the same time in a protein digest.  相似文献   

18.
Wu QQ 《Analytical chemistry》1998,70(5):865-872
A "basket in a basket" method based on a multistage accurate mass spectrometric (MAMS) technique was developed and demonstrated by obtaining a unique elemental composition of a compound (with a molecular weight of 517) from combinatorial synthesis. The accurate masses for the parent and the fragment ions were obtained with up to five stages of MAMS using Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). This approach requires only input of elements used in the synthetic processes and some constraints about unusual light elements, such as fluorine, while the compositions of the parent ions and their fragments are obtained for structure elucidation. Conversely, accuracy of better than 0.02 ppm (assuming elements C, H, N, O, S, and F are involved) would be required in order to define a unique composition for the same mass using a direct accurate mass measurement because the number of possible elemental compositions increases sharply as the mass increases. Similarly, due to the uncertainty in determining elemental compositions of fragments and complexity of possible internal fragmentation, tandem mass spectrometry may not provide enough information for structure elucidation of unknown compounds, especially of the organic molecules in the mass range of 300-1000 Da, typically encountered in combinatorial lead generation. The application of MAMS to combinatorial drug discovery is particularly advantageous since the built-in chemical information from the synthesis can be used as constraints. The implementation of a nanoelectrospray ionization technique makes this approach practical for characterization of small quantities of compounds typically available from lead generation processes.  相似文献   

19.
A direct current induced vacuum ultraviolet (dc-VUV) krypton discharge lamp and an alternating current, radio frequency (rf) induced VUV lamp that are essentially similar to lamps in commercial atmospheric pressure photoionization (APPI) ion sources were compared. The emission distributions along the diameter of the lamp exit window were measured, and they showed that the beam of the rf lamp is much wider than that of the dc lamp. Thus, the rf lamp has larger efficient ionization area, and it also emits more photons than the dc lamp. The ionization efficiencies of the lamps were compared using identical spray geometries with both lamps in microchip APPI mass spectrometry (μAPPI-MS) and desorption atmospheric pressure photoionization-mass spectrometry (DAPPI-MS). A comprehensive view on the ionization was gained by studying six different μAPPI solvent compositions, five DAPPI spray solvents, and completely solvent-free DAPPI. The observed reactant ions for each solvent composition were very similar with both lamps except for toluene, which showed a higher amount of solvent originating oxidation products with the rf lamp than with the dc lamp in μAPPI. Moreover, the same analyte ions were detected with both lamps, and thus, the ionization mechanisms with both lamps are similar. The rf lamp showed a higher ionization efficiency than the dc lamp in all experiments. The difference between the lamp ionization efficiencies was greatest when high ionization energy (IE) solvent compositions (IEs above 10 eV), i.e., hexane, methanol, and methanol/water, (1:1 v:v) were used. The higher ionization efficiency of the rf lamp is likely due to the larger area of high intensity light emission, and the resulting larger efficient ionization area and higher amount of photons emitted. These result in higher solvent reactant ion production, which in turn enables more efficient analyte ion production.  相似文献   

20.
Oak wood and oak bark chars were obtained from fast pyrolysis in an auger reactor at 400-450 °C. These chars were characterized and utilized for Cr(VI) remediation from water. Batch sorption studies were performed at different temperatures, pH values and solid to liquid ratios. Maximum chromium was removed at pH 2.0. A kinetic study yielded an optimum equilibrium time of 48 h with an adsorbent dose of 10 g/L. Sorption studies were conducted over a concentration range of 1-100mg/L. Cr(VI) removal increased with an increase in temperature (Q(Oak wood)(°): 25 °C = 3.03 mg/g; 35 °C = 4.08 mg/g; 45 °C = 4.93 mg/g and Q(Oakbark)(°): 25 °C = 4.62 mg/g; 35 °C = 7.43 mg/g; 45 °C = 7.51 mg/g). More chromium was removed with oak bark than oak wood. The char performances were evaluated using the Freundlich, Langmuir, Redlich-Peterson, Toth, Radke and Sips adsorption isotherm models. The Sips adsorption isotherm model best fits the experimental data [high regression (R(2)) coefficients]. The overall kinetic data was satisfactorily explained by a pseudo second order rate expression. Water penetrated into the char walls exposing Cr(VI) to additional adsorption sites that were not on the surfaces of dry char pores. It is remarkable that oak chars (S(BET): 1-3m(2)g(-1)) can remove similar amounts of Cr(VI) as activated carbon (S(BET): ~ 1000 m(2)g(-1)). Thus, byproduct chars from bio-oil production might be used as inexpensive adsorbents for water purification. Char samples were successfully used for chromium remediation from contaminated surface water with dissolved interfering ions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号