首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
In this paper we introduce laser ablation atmospheric pressure photoionization (LAAPPI), a novel atmospheric pressure ion source for mass spectrometry. In LAAPPI the analytes are ablated from water-rich solid samples or from aqueous solutions with an infrared (IR) laser running at 2.94 μm wavelength. Approximately 12 mm above the sample surface, the ablation plume is intercepted with an orthogonal hot solvent (e.g., toluene or anisole) jet, which is generated by a heated nebulizer microchip and directed toward the mass spectrometer inlet. The ablated analytes are desolvated and ionized in the gas-phase by atmospheric pressure photoionization using a 10 eV vacuum ultraviolet krypton discharge lamp. The effect of operational parameters and spray solvent on the performance of LAAPPI is studied. LAAPPI offers ~300 μm lateral resolution comparable to, e.g., matrix-assisted laser desorption ionization. In addition to polar compounds, LAAPPI efficiently ionizes neutral and nonpolar compounds. The bioanalytical application of the method is demonstrated by the direct LAAPPI analysis of rat brain tissue sections and sour orange (Citrus aurantium) leaves.  相似文献   

2.
A direct current induced vacuum ultraviolet (dc-VUV) krypton discharge lamp and an alternating current, radio frequency (rf) induced VUV lamp that are essentially similar to lamps in commercial atmospheric pressure photoionization (APPI) ion sources were compared. The emission distributions along the diameter of the lamp exit window were measured, and they showed that the beam of the rf lamp is much wider than that of the dc lamp. Thus, the rf lamp has larger efficient ionization area, and it also emits more photons than the dc lamp. The ionization efficiencies of the lamps were compared using identical spray geometries with both lamps in microchip APPI mass spectrometry (μAPPI-MS) and desorption atmospheric pressure photoionization-mass spectrometry (DAPPI-MS). A comprehensive view on the ionization was gained by studying six different μAPPI solvent compositions, five DAPPI spray solvents, and completely solvent-free DAPPI. The observed reactant ions for each solvent composition were very similar with both lamps except for toluene, which showed a higher amount of solvent originating oxidation products with the rf lamp than with the dc lamp in μAPPI. Moreover, the same analyte ions were detected with both lamps, and thus, the ionization mechanisms with both lamps are similar. The rf lamp showed a higher ionization efficiency than the dc lamp in all experiments. The difference between the lamp ionization efficiencies was greatest when high ionization energy (IE) solvent compositions (IEs above 10 eV), i.e., hexane, methanol, and methanol/water, (1:1 v:v) were used. The higher ionization efficiency of the rf lamp is likely due to the larger area of high intensity light emission, and the resulting larger efficient ionization area and higher amount of photons emitted. These result in higher solvent reactant ion production, which in turn enables more efficient analyte ion production.  相似文献   

3.
The factors influencing desorption and ionization in newly developed desorption atmospheric pressure photoionization-mass spectrometry (DAPPI-MS) were studied. Redirecting the DAPPI spray was observed to further improve the versatility of the technique: for dilute samples, parallel spray with increased analyte signal was found to be the best suited, while for more concentrated samples, the orthogonal spray with less risk for contamination is recommended. The suitability of various spray solvents and sampling surface materials was tested for a variety of analytes with different polarities and molecular weights. As in atmospheric pressure photoionization, the analytes formed [M + H](+), [M - H](-), M(+*), M(-*), [M - H + O](-), or [M - 2H + 2O](-) ions depending on the analyte, spray solvent, and ionization mode. In positive ion mode, anisole and toluene as spray solvents promoted the formation of M(+*) ions and were therefore best suited for the analysis of nonpolar compounds (anthracene, benzo[a]pyrene, and tetracyclone). Acetone and hexane were optimal spray solvents for polar compounds (MDMA, testosterone, and verapamil) since they produced intensive [M + H](+) ion peaks of the analytes. In negative ion mode, the type of spray solvent affected the signal intensity, but not the ion composition. M(-*) ions were formed from 1,4-dinitrobenzene, and [M - H + O](-) and [M - 2H + 2O](-) ions from 1,4-naphthoquinone, whereas acidic compounds (naphthoic acid and paracetamol) formed [M - H](-) ions. The tested sampling surfaces included various materials with different thermal conductivities. The materials with low thermal conductivity, i.e., polymers like poly(methyl methacrylate) and poly(tetrafluoroethylene) (Teflon) were found to be the best, since they enable localized heating of the sampling surface, which was found to be essential for efficient analyte desorption. Nevertheless, the sampling surface material did not affect the ionization mechanisms.  相似文献   

4.
We present a new method for molecular characterization of intact biochar directly, without sample preparation or pretreatment, on the basis of desorption atmospheric pressure photoionization (DAPPI) coupled to Fourier transform ion cyclotron resonance (FTICR) mass spectrometry. Conventional ionization methods (e.g., electrospray or atmospheric pressure photoionization) for characterization of natural organic matter have limited utility for the characterization of chars due to incomplete solubility in common solvents. Therefore, direct ionization techniques that do not require sample dissolution prior to analysis are ideal. Here, we apply DAPPI FTICR mass spectrometry to enable the first molecular characterization of uncharred parent oak biomass and after combustion (250 °C) or pyrolysis (400 °C). Parent oak is primarily composed of cellulose-, lignin-, and resin-like compounds. Oak combusted at 250 °C contains condensed aromatic compounds with low H/C and O/C ratios while retaining compounds with high H/C and O/C ratios. The bimodal distribution of aromatic and aliphatic compounds observed in the combusted oak sample is attributed to incomplete thermal degradation of lignin and hemicellulose. Pyrolyzed oak constituents exhibit lower H/C and O/C ratios: approximately three-quarters of the identified species are aromatic. DAPPI FTICR MS results agree with bulk elemental composition as well as functional group distributions determined by elemental analysis and solid state (13)C NMR spectroscopy. Complete molecular characterization of biomass upon thermal transformation may provide insight into the biogeochemical cycles of biochar and future renewable energy sources, particularly for samples currently limited by solubility, separation, and sample preparation.  相似文献   

5.
The analysis of analytes deposited on, separated on, or otherwise distributed about a planar surface using desorption electrospray ionization mass spectrometry in a surface scanning sampling mode was investigated. The physical regions of the surface-impacting solvent/gas jet desorption/ionization plume were described. Under the conditions typical for desorption electrospray ionization used here, the impact plume formed an elliptical desorption/ionization region on the surface. Most effective desorption/ionization was obtained from a smaller elliptical area within the larger impact region that was centered on a point on-axis from the sprayer tip to the surface. Maximum signal from a given amount of material on a surface was observed with proper plume and sample alignment when the diameter of the sample spot was less than the diameter of the central high-efficiency desorption/ionization region of the impact plume. Solvent and gas flow out of this high-efficiency desorption/ionization region was found to limit analyte accessibility to this region via a "washing effect" when analytes were on smooth surfaces or on surfaces for which the analyte had little affinity. As such, the direction of surface scanning and scan speed during an analysis was found to be important for maximizing signal levels and signal reproducibility on particular surface types. Overall, the results presented illustrate means to improve analysis of sample spots on various types of surfaces using desorption electrospray ionization mass spectrometry in a surface scanning mode.  相似文献   

6.
Electron impact ionization has several known advantages; however, heated filament electron sources have pressure limitations and their power consumption can be significant for certain applications, such as in field-portable instruments. Herein, we evaluate a VUV krypton lamp as an alternative source for ionization inside the ion trap of a mass spectrometer. The observed fragmentation patterns are more characteristic of electron impact ionization than photoionization. In addition, mass spectra of analytes with ionization potentials higher than the lamp's photon energy (10.6 eV) can be easily obtained. A photoelectron impact ionization mechanism is suggested by the observed data allowed by the work function of the ion trap electrodes (4.5 eV), which is well within the lamp's photon energy. In this case, the photoelectrons emitted at the surface of the ion trap end-cap electrode are accelerated by the applied rf field to the ring electrode. This allows the photoelectrons to gain sufficient energy to ionize compounds with high ionization potentials to yield mass spectra characteristic of electron impact. In this manner, electron impact ionization can be used in ion trap mass spectrometers at low powers and without the limitations imposed by elevated pressures on heated filaments.  相似文献   

7.
A novel, microfabricated heated nebulizer chip for atmospheric pressure photoionization-mass spectrometry (APPI-MS) is presented. The chip consists of fluidic and gas inlets, a mixer, and a nozzle etched onto silicon wafer that is anodically bonded to a Pyrex glass wafer, on which an aluminum heater is sputtered. A krypton discharge lamp is used as the source for 10-eV photons to initiate the photoionization process. Dopant, delivered as part of the sample solution, is used to achieve efficient ionization. The use of the microfabricated heated nebulizer with APPI in the analysis of four analytes is demonstrated, and the spectra are compared to those obtained with a conventional APPI source. Ionization in positive and negative ion modes was successfully achieved and the spectra were mainly similar to those obtained with conventional APPI, indicating that the ionization in microfabricated and conventional APPI sources takes place by the same mechanisms. The flow rates with conventional APPI are approximately 100 muL/min, whereas the microchip heated nebulizer allows the use of flow rates 0.05-5 muL/min, thus being compatible with microfluidic separation systems or micro- and nano-LC. A stable signal was demonstrated throughout a 5-h measurement, which proved the excellent stability of the micro-APPI. The same heated nebulizer chip can be used for weeks.  相似文献   

8.
Zhang Q  Wodtke AM 《Analytical chemistry》2005,77(23):7612-7617
Cocrystallization between analyte and matrix is required by matrix-assisted laser desorption/ionization and can represent a significant limitation of the technique. A molecular beam expansion, mass spectrometric method has been developed to explore the possibility of using pure solvents as matrix to avoid cocrystallization. Two kinds of solvent, liquid CS2 and liquid or supercritical CO2, have been studied with 266-nm UV laser irradiation. We successfully ionized a number of compounds, including caffeine, guanine, cholesterol, and mixed fullerenes. Under some conditions, the mass spectra reflect parent radical cations formed by photoionization. Under other conditions, protonated, sodiated (and with CS2 even sulfated) ions are seen reflecting a nonunimolecular ionization process. When UV-transparent CO2 is used as a solvent, only analyte molecules with a UV chromophore are detected. However, with UV-absorbing CS2, we demonstrate ionization of molecules lacking a UV chromophore. This work provides strong evidence that one can form solvent clusters containing analyte, that laser photoionization of the solvent precedes ionization of the analyte, and that solvent evaporation along with the indirect ionization leads to reduced parent ion fragmentation. The exploration of this now demonstrated concept with other solvents would appear fruitful for future work.  相似文献   

9.
The coupling of a rotation planar preparative thin-layer chromatography system on-line with mass spectrometry is demonstrated using a simple plumbing scheme and a self-aspirating heated nebulizer probe of a corona discharge atmospheric pressure chemical ionization source. The self-aspiration of the heated nebulizer delivers approximately 20 microL/min of the 3.0 mL/min eluate stream to the mass spectrometer, eliminating the need for an external pump in the system. The viability of the coupling is demonstrated with a three-dye mixture composed of fat red 7B, solvent green 3, and solvent blue 35 separated and eluted from a silica gel-coated rotor using toluene. The real-time characterization of the dyes eluting from the rotor is illustrated in positive ion full-scan mode. Other self-aspirating ion source systems including atmospheric pressure photoionization, electrospray ionization, and inductively coupled plasma ionization, for example, might be configured and used in a similar manner coupled to the chromatograph to expand the types of analytes that could be ionized, detected, and characterized effectively.  相似文献   

10.
Atmospheric pressure photoionization (APPI) has been successfully demonstrated to provide high sensitivity to LC-MS analysis. A vacuum-ultraviolet lamp designed for photoionization detection in gas chromatography is used as a source of 10-eV photons. The mixture of samples and solvent eluting from an HPLC is fully evaporated prior to introduction into the photoionization region. In the new method, large quantities of an ionizable dopant are added to the vapor generated from the LC eluant, allowing for a great abundance of dopant photoions to be produced. Because the ion source is at atmospheric pressure, and the collision rate is high, the dopant photoions react to completion with solvent and analyte molecules present in the ion source. Using APPI, at an LC flow rate of 200 microL/min, it is possible to obtain analyte signal intensities 8 times as high as those obtainable with a commercially available corona discharge-atmospheric pressure chemical ionization source.  相似文献   

11.
Biotin and biotinylated self-assembled monolayers (SAMs) on gold have been investigated using time-of-flight secondary ion mass spectrometry, direct laser desorption, laser desorption with 193 nm photoionization of ion- and laser-desorbed species, and laser desorption with vacuum ultraviolet (VUV, 118 nm) photoionization. Our results indicate that direct laser desorption and laser desorption combined with 193 nm multiphoton ionization can detect a chromophoric molecule like biotin that is covalently bound to a SAM. However, secondary ion mass spectra were dominated by fragmentation, and ion desorption/193 nm photoionization detected no species related to biotin. The dominant features of the laser desorption/VUV mass spectra were neat and Au-complexed dimers of intact and fragmented biotinylated SAM molecules. Multiphoton and single-photon ionization of laser-desorbed neutrals from biotinylated SAMs both led to the production of ions useful for chemical analysis of the monolayer. Multiphoton ionization with ultraviolet radiation was experimentally less challenging but required a chromophore for ionization and resulted in significant fragmentation of the adsorbate. Single-photon ionization with VUV radiation was experimentally more challenging but did not require a chromophore and led to less fragmentation. X-ray photoelectron spectra indicated that the biotinylated SAM formed a disordered, 40-60 ? thick monolayer on Au. Additionally, projection photolithography with a Schwarzschild microscope was used to pattern the biotinylated SAM surface and laser desorption/photoionization was used to detect biotinylated adsorbates from the ~10 μm sized pattern.  相似文献   

12.
The ionization mechanism in dopant-assisted atmospheric pressure photoionization and the effect of solvent on the ionization efficiency was studied using 7 naphthalenes and 13 different solvent systems. The ionization efficiency was 1-2 orders of magnitude higher with dopant than without, indicating that the photoionization of the dopant initiates the ionization process. In positive ion mode, the analytes were ionized either by charge exchange or by proton transfer. Charge exchange was favored for low proton affinity solvents (water, hexane, chloroform), whereas the addition of methanol or acetonitrile to the solvent initiated proton transfer. In negative ion mode, the compounds with high electron affinity were ionized by electron capture or by charge exchange and the compounds with high gas-phase acidity were ionized by proton transfer. In addition, some oxidation reactions were observed. All the reactions leading to ionization of analytes in negative ion mode are initiated by thermal electrons formed in photoionization of toluene. The testing of different solvents showed that addition of buffers such as ammonium acetate, ammonium hydroxide, or acetic acid may suppress ionization in APPI. The reactions are discussed in detail in light of thermodynamic data.  相似文献   

13.
A new built instrument suitable for laser desorption-single photon ionization time-of-flight mass spectrometry (LD-SPI-TOFMS) with use of Vacuum-UV photons with a wavelength of 118 nm was used for the analysis of organic compounds. Fragmentation-free analysis of a variety of substances was achieved for desorption experiments with pure compounds desorbed from quartz glass filters applying low desorption energies. It was further found that the rate of fragmentation is strongly dependent on the desorption energy. Matrix effects were investigated by desorption experiments utilizing soot spiked with several organic compounds.The characteristics of the desorption process are assessed in more detail and the impact on the analysis of ambient particulate matter (PM) samples on filters are discussed. First results obtained from the application of the technique to the analysis of organic compounds from ambient PM are presented. Furthermore, possibilities of future developments of the method, in particular for analysis of ambient PM, are discussed.  相似文献   

14.
Manipulation of protein charge states in electrospray ionization-mass spectrometry (ESI-MS) has implications for the study of intact proteins, protein-protein interactions, post-translational modifications, and protein sequencing. Control of these protein charge states is often difficult to achieve with conventional methods of analysis. A novel ambient ionization configuration, continuous flow-extractive desorption electrospray ionization (CF-EDESI), is presented as a means to control the charge state distribution of proteins. A key feature of the CF-EDESI technique is the continuous flow needle, which is a hypodermic needle presented orthogonal to the electrospray source and delivers a solvent flow containing analytes for extractive desorption ionization. With this source design, the successful manipulation of cytochrome c and lysozyme charge states with the use of different additives, such as acetic acid and sulfolane, was demonstrated. Results were compared to data obtained with conventional electrospray ionization. Good agreement with previously reported studies of cytochrome c unfolding/folding studies, performed by conventional ESI-MS, is evident. In addition to the protein analysis presented, the CF-EDESI-MS technique should be applicable for analyzing atypical analyte and solvent systems by mass spectrometry while maintaining optimal electrospray source conditions.  相似文献   

15.
Zhang J  Li Z  Zhang C  Feng B  Zhou Z  Bai Y  Liu H 《Analytical chemistry》2012,84(7):3296-3301
In this work, an extremely simple and quite sensitive mass spectrometric method termed ambient surface-assisted laser desorption/ionization mass spectrometry (ambient SALDI-MS) was developed to analyze different kinds of compounds, just using a piece of graphite-coated paper for the sample introduction. This provides great advantage in simplifying the analysis process. The method is quite easy to use, and there is no need to worry about the source of graphite, that is, the brands or the types of pencil. And the whole process was carried out under atmospheric pressure, offering all the merits that could occur in ambient MS. The improved sensitivity of this method is mainly because of the graphite, which serves as energy-transfer medium to absorb the energy of the photons and release it to the analytes that are adsorbed on the graphite surface. Also, three different laser wavelengths (1064, 532, and 355 nm) was tested to investigate the desorption mechanism. Fifty-one compounds, with varied chemical structures, were tried to prove that this new method possessed universal applicability to detect different kinds of small organic molecules.  相似文献   

16.
A different design for the atmospheric pressure photoionization (APPI) source, other than commercially available sources, such as PhotoSpray and PhotoMate, has been proposed. Unlike PhotoSpray, this design applies an electric field to separate photoions and electrons. In addition, the UV radiation is parallel to the gas stream toward the mass spectrometer sampling aperture. The total ion current obtained using this geometry, for dopant only, could be an order of magnitude larger than that obtained using the PhotoSpray design. Additionally, to prevent the negative effect of solvent on the photoionization yield, a curtain electrode was mounted in front of the UV lamp to divide the ionization zone into two distinct regions: the dopant and the solvent regions. Dopant was introduced in the vicinity of the lamp, and vaporized solvent was introduced into the solvent region. The curtain electrode prevented the solvent from entering the dopant region where dopant was directly photoionized. This design consumes much less dopant (approximately 1/10 less) than the conventional source, which minimizes the presence of photofragmented radicals and dopant trace contaminants in the ionization region. As a result, unlike PhotoSpray, the mass spectra contained mainly the analyte and solvent peaks. Additionally, the source was tested using an ion mobility spectrometer (IMS). The effect of the curtain electrode on signal intensity and performance of the source using IMS was also proved to be positive.  相似文献   

17.
This work reports on a new and extremely simple approach for determination of a double bond position by a laser desorption ionization mass spectrometry. It is solely based on the catalytic properties of nanostructured surfaces used in nanoassisted laser desorption ionization experiments. These surfaces can induce oxidation of analytes, which results in a mass shift that can be detected by mass spectrometry. If a site of unsaturation is oxidized and cleaved, the m/z difference is diagnostic of the position of a double bond. By demonstrating that the oxidation depends on the analyte surface dwell time, it was proven that it is caused by the surface activity and not by the laser desorption ionization process itself. Control matrix-assisted laser desorption/ionization (MALDI) experiment showed only a limited partial oxidation and no time dependency of the process. The ability to determine a position of a double bond was demonstrated on polyunsaturated phospholipids and cyclosporine A. In some other cases, however, the unexpected oxidation could cause confusion, as demonstrated for a glycosphingolipid from a porcine brain extract.  相似文献   

18.
A new technique for preparing samples for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is reported. The technique relies on electrowetting-on-dielectric (EWOD) to move droplets containing proteins or peptides and matrix to specific locations on an array of electrodes for analysis. Standard MALDI-MS reagents, analytes, concentrations, and recipes are demonstrated to be compatible with the technique. Mass spectra are comparable to those collected by conventional methods. Nonspecific adsorption of analytes to device surfaces is demonstrated to be negligible. The results suggest that EWOD may be a useful tool for automating sample preparation for high-throughput proteomics and other applications of MALDI-MS.  相似文献   

19.
Hua L  Wu Q  Hou K  Cui H  Chen P  Wang W  Li J  Li H 《Analytical chemistry》2011,83(13):5309-5316
A novel combined ion source based on a vacuum ultraviolet (VUV) lamp with both single photon ionization (SPI) and chemical ionization (CI) capabilities has been developed for an orthogonal acceleration time-of-flight mass spectrometer (oaTOFMS). The SPI was accomplished using a commercial 10.6 eV krypton discharge lamp with a photon flux of about 10(11) photons s(-1), while the CI was achieved through ion-molecule reactions with O(2)(+) reactant ions generated by photoelectron ionization at medium vacuum pressure (MVP). To achieve high ionization efficiency, the ion source pressure was elevated to 0.3 mbar and the photoionization length was extended to 36 mm. As a result, limits of detection (LODs) down to 3, 4, and 6 ppbv were obtained for benzene, toluene, and p-xylene in MVP-SPI mode, and values of 8 and 10 ppbv were obtained for toluene and chloroform, respectively, in SPI-CI mode. As it is feasible to switch between MVP-SPI mode and SPI-CI mode rapidly, this system is capable of monitoring complex organic mixtures with a wide range of ionization energies (IEs). The analytical capacity of this system was demonstrated by measuring dehydrogenation products of long-chain paraffins to olefins through direct capillary sampling and drinking water disinfection byproducts from chlorine through a membrane interface.  相似文献   

20.
A generic high-performance liquid chromatography (HPLC) system interfaced with an atmospheric pressure photoionization (APPI) source and a tandem mass spectrometer was developed for the quantitative determination of small molecules in plasma in support of exploratory in vivo pharmacokinetics. This report summarizes the effects of variations in reversed-phase mode HPLC conditions such as mobile-phase flow rate, solvent composition, organic modifier content, and nebulizer temperature on the photoionization efficiency of both clozapine and lonafarnib. The matrix ionization suppression effect on this method was investigated using the postcolumn infusion technique. The procedure was used to quantitate plasma levels following oral administration of 42 drug discovery compounds to rats. The pharmacokinetic results of 42 drug discovery compounds in rats evaluated by both APPI and atmospheric pressure chemical ionization interfaces were found to be well correlated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号