首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Accurate and noninvasive measurement of tissue optical properties can be used for biomedical diagnostics and monitoring of tissue analytes. Noninvasive measurement of tissue optical properties (total attenuation and scattering coefficients, optical thickness, etc.) can be performed with the optical coherence tomography (OCT) technique. However, speckle noise substantially deteriorates the accuracy of the measurements with this technique. We studied suppression of speckle noise for accurate measurement of backscattering signal and scattering coefficient with the OCT technique. Our results demonstrate that the precision of measurement of backscattering signals with the OCT technique can be 0.2% for homogeneously scattering media and 0.7% for skin, if spatial averaging of speckle noise is applied. This averaging allows us to achieve the precision of tissue scattering coefficient measurements of approximately +/-0.8%. This precision can be further improved by a factor of 2-3, upon optimization of OCT operating parameters.  相似文献   

2.
For optical coherence tomography (OCT), ultrasound, synthetic-aperture radar, and other coherent ranging methods, speckle can cause spurious detail that detracts from the utility of the image. It is a problem inherent to imaging densely scattering objects with limited bandwidth. Using a method of regularization by minimizing Csiszar's I-divergence measure, we derive a method of speckle minimization that produces an image that both is consistent with the known data and extrapolates additional detail based on constraints on the magnitude of the image. This method is demonstrated on a test image and on an OCT image of a Xenopus laevis tadpole.  相似文献   

3.
《Composites Part A》1999,30(2):139-145
Optical coherence tomography (OCT) is a nondestructive and noncontact technique to image microstructure within scattering media. The application of OCT to highly scattering materials such as polymer composites is especially challenging. In this work, OCT is evaluated as a technique to image fiber tows and voids in two materials: an epoxy E-glass-reinforced composite and a vinyl-ester E-glass-reinforced composite. Features detected using OCT are compared with optical microscopy. Fiber architecture and voids of glass-reinforced polymer composites can be successfully imaged using OCT. The quality of the OCT image is strongly affected by the refractive index mismatch between the fibers and reinforcement. The largest sources of noise in the images arise from fiber lens effects, interference from within the sample, and a very large reflection at the surface.  相似文献   

4.
An adaptive total variation method based on the combination of speckle statistics and total variation restoration is proposed and developed for reducing speckle noise in optical coherence tomography (OCT) images. The statistical distribution of the speckle noise in OCT image is investigated and measured. With the measured parameters such as the mean value and variance of the speckle noise, the OCT image is restored by the adaptive total variation restoration method. The adaptive total variation restoration algorithm was applied to the OCT images of a volunteer’s hand skin, which showed effective speckle noise reduction and image quality improvement. For image quality comparison, the commonly used median filtering method was also applied to the same images to reduce the speckle noise. The measured results demonstrate the superior performance of the adaptive total variation restoration method in terms of image signal-to-noise ratio, equivalent number of looks, contrast-to-noise ratio, and mean square error.  相似文献   

5.
Abstract

The dynamic properties of doubly-scattered speckles produced at the image plane have been investigated using a scattering model that consists of a coherent Gaussian beam, a cascade of two moving diffusers and a single imaging lens. Dependence of the fluctuation speed of time-varying image speckles on the velocities of the diffusers is found to change with the size of illuminating speckles and the width of the point-spread function of the imaging lens. When the point-spread function and the focal position satisfy certain conditions, three kinds of velocity information—the velocity of each diffuser, the average velocity of the diffusers and the velocity difference between the diffusers—can be obtained by measuring a temporal correlation length of the time-varying speckle intensity. Experimental results confirm the theoretical predictions.  相似文献   

6.
《Journal of Modern Optics》2013,60(8):951-960
An extensive experimental study on the average contrast of speckle patterns produced by white light at the image plane is reported in this paper. The speckle contrast is found to be determined by the complicated relationship between the spatial coherence of illuminating light, the point spread of an imaging system and the roughness properties of the objects. It is found that the previous results of Sprague, Parry and Pedersen on white-light speckle patterns are realized only when the object is spatially coherently illuminated and a large number of scattering cells are involved within the point spread of the imaging system.  相似文献   

7.
Diffusive media characterization with laser speckle   总被引:1,自引:0,他引:1  
Thompson CA  Webb KJ  Weiner AM 《Applied optics》1997,36(16):3726-3734
The statistical properties of laser speckle with partially coherent light are related to the scattering characteristics of an optically diffuse material. A diffusion equation model is shown to yield a speckle contrast ratio that agrees well with measurements of opaque plastics of varying thicknesses. We show that partially coherent light can be used to determine material parameters for highly scattering media. Measured data for stratified materials with differing scattering properties indicate that this technique may be useful in detecting inhomogeneities.  相似文献   

8.
线聚焦光学相干层析术的研究   总被引:1,自引:1,他引:0  
提出了一种高速光学相干层析(OCT)成像技术方案。利用柱面镜的成像特性将传统OCT的点聚焦成像模式改变为线聚焦成像模式,从而降低二维OCT图像的扫描维数,达到提高成像速度的目的。利用ZEMAX光学软件对系统进行光线追迹获得光束经过柱面镜后的聚焦情况。随后采用635nm的激光光源和柱面镜构建了实验系统,实验结果很好地验证了光线追迹仿真结果。  相似文献   

9.
A multiple-frequency inverse scattering method that uses eigenfunctions of a scattering operator is extended to image large-scale and high-contrast objects. The extension uses an estimate of the scattering object to form the difference between the scattering by the object and the scattering by the estimate of the object. The scattering potential defined by this difference is expanded in a basis of products of acoustic fields. These fields are defined by eigenfunctions of the scattering operator associated with the estimate. In the case of scattering objects for which the estimate is radial, symmetries in the expressions used to reconstruct the scattering potential greatly reduce the amount of computation. The range of parameters over which the reconstruction method works well is illustrated using calculated scattering by different objects. The method is applied to experimental data from a 48-mm diameter scattering object with tissue-like properties. The image reconstructed from measurements has, relative to a conventional B-scan formed using a low f-number at the same center frequency, significantly higher resolution and less speckle, implying that small, high-contrast structures can be demonstrated clearly using the extended method.  相似文献   

10.
Abstract: The present study is concerned with the application of optical coherence tomographic (OCT) elastography technique for quantitative assessment of the elastic properties of resected human breast tissue samples subjected to axial compressive loading in vitro. Three classes of breast tissue samples, namely normal, benign (fibroadenoma) and malignant (invasive ductal carcinoma), were considered. A speckle tracking technique based on two‐dimensional cross correlation was employed to track the speckle motion between original (pre‐compressed) and the displaced (post‐compressed) OCT images of the tissue samples for the measurement of displacement and strain maps. The overall data reduction approach for quantitative assessment of elastic properties was validated against the results of gelatin phantoms containing activated charcoal particles as scattering centres. Results are presented in the form of OCT images and displacement and axial strain maps for normal, benign and malignant breast tissue samples. Based on the stress–strain relationship obtained for these three classes, the values of stiffness coefficients were reported in terms of modulus of elasticity. Results of the study reveal significant differences between the two‐dimensional displacement vector maps of normal and cancerous breast tissue samples. The stiffness of benign tissue samples is found to be about two times higher than that of normal tissue samples, whereas for malignant samples, it is about four times higher, thereby signifying appreciable differences in the stiffness of cancerous and normal tissue samples.  相似文献   

11.
Cao L  Pan G  de Jong J  Woodward S  Meng H 《Applied optics》2008,47(25):4501-4508
To apply digital holography to the measurement of three-dimensional dense particle fields in large facilities, we have developed a hybrid digital holographic particle-imaging system. The technique combines the advantages of off-axis (side) scattering in suppressing speckle noise and on-axis (in-line) recording in lowering the digital sensor resolution requirement. A camera lens is attached to the digital sensor to compensate for the weak object wave from side scattering over a large recording distance. A simple numerical reconstruction algorithm is developed for holograms recorded with a lens without requiring complex and impractical mathematical corrections. We analyze the effect of image sensor resolution and off-axis angle on system performance and quantify the particle positioning accuracy of the system. The holographic system is successfully applied to the study of inertial particle clustering in isotropic turbulence.  相似文献   

12.
A quantitative method for determining the depth of burn eschar would aid surgeons in determining whether to excise and subsequently graft a burn wound. We hypothesize that tissue viability could be assessed by an analysis of the spatial modulation of near-field laser speckle by flowing blood. A feasibility study of the technique was performed with two-layer tissue phantoms used to simulate a burn wound. A sheet of polytetrafluoroethylene (PTFE) was used to simulate nonperfused burn eschar, and tissue perfusion within deeper layers was represented by Brownian motion from a scattering solution. A low-power He-Ne laser was focused onto the target, and the resulting speckle image was captured with a CCD camera and stored on a computer for further processing. The diameter of the speckle pattern was found to be directly proportional to the thickness of the overlying layer. These data suggest that the thickness of PTFE can be determined to ±100-μm accuracy with 95% confidence and may be suitable for burn depth detection in vivo.  相似文献   

13.
We describe a new semiautomatic image processing method for detecting the cartilage boundaries in optical coherence tomography (OCT). In particular, we focus on rabbit cartilage since this is an important animal model for testing both chondroprotective agents and cartilage repair techniques. The novel boundary-detection system presented here consists of (1) an adaptive filtering technique for image enhancement and speckle reduction, (2) edge detection, and (3) edge linking by graph searching. The procedure requires several steps and can be automated. The quantitative measurements of cartilage thickness on OCT images correlated well with measurements from histology.  相似文献   

14.
We present a detailed analytical model to describe optical coherence tomography (OCT) systems, which considers the propagation of the optical field within a scattering medium in the framework of the extended Huygens-Fresnel principle. The model includes use of the discrete-particle model and the fractal approach in treating biological tissue as being packed with scattering particles with a power-law distribution. In contrast to previous models, an imaginary lens proximal to the tissue surface is introduced that approximates the real focusing lens in the sample arm of the OCT system. This treatment avoids the consideration of backscattering light as traveling in the free space between the focusing lens and the tissue surface before mixing with the reference beam. Experiments on tissue phantoms were carried out to verify the validity of this model.  相似文献   

15.
In holographic imaging of particle fields, the interference among coherent wave fronts associated with particle scattering gives rise to intrinsic speckle noise, which sets a fundamental limit on the amount of information that particle holography can deliver. It has been established that the intrinsic speckle noise is especially severe in in-line holography because of superposition of virtual image waves, the direct transmitted wave, and the real image. However, at sufficiently high particle number densities, such as those typical in holographic particle image velocimetry (HPIV) applications, intrinsic speckle noise also arises in off-axis particle holography from self-interference among wave fronts that form the real image of particles. To overcome the latter problem we have constructed a mathematical model that relates the first- and second-order statistical properties of the intrinsic speckle noise to relevant holographic system parameters. Consistent with our experimental data, the model provides a direct estimate of the information capacity of particle holography. We show that the noise-limited information capacity can be expressed as the product of particle number density and the extent of the particle field along the optical axis. A large angular aperture of the hologram contributes directly to achievement of high information capacity. We also show that filtering in either digital or optical form is generally ineffective in removing the intrinsic speckle noise from the particle image as a result of the similar spectral properties of the two. These findings emphasize the importance of angular aperture in designing holographic particle imaging systems.  相似文献   

16.
Mie scattering computations have been performed for light scattered by small particles from a pulsed sheet of laser illumination and collected and imaged by a camera lens. From these computations the smallest particles that can be photographed in various fluid measurement situations, including air and water, have been determined in terms of system parameters such as laser power, light sheet geometry, f/No., and photographic film properties. The particle scattering requirements of the individual particle image mode and the speckle mode are compared.  相似文献   

17.
Lu RS  Tian GY  Gledhill D  Ward S 《Applied optics》2006,45(35):8839-8847
Surface speckle pattern intensity distribution resulting from laser light scattering from a rough surface contains various information about the surface geometrical and physical properties. A surface roughness measurement technique based on the texture analysis of surface speckle pattern texture images is put forward. In the surface roughness measurement technique, the speckle pattern texture images are taken by a simple setup configuration consisting of a laser and a CCD camera. Our experimental results show that the surface roughness contained in the surface speckle pattern texture images has a good monotonic relationship with their energy feature of the gray-level co-occurrence matrices. After the measurement system is calibrated by a standard surface roughness specimen, the surface roughness of the object surface composed of the same material and machined by the same method as the standard specimen surface can be evaluated from a single speckle pattern texture image. The robustness of the characterization of speckle pattern texture for surface roughness is also discussed. Thus the surface roughness measurement technique can be used for an in-process surface measurement.  相似文献   

18.
Yao G  Wang LV 《Applied optics》2004,43(6):1320-1326
A Monte Carlo modeling technique was used to simulate ultrasound-modulated optical tomography in inhomogeneous scattering media. The contributions from two different modulation mechanisms were included in the simulation. Results indicate that ultrasound-modulated optical signals are much more sensitive to small embedded objects than unmodulated intensity signals. The differences between embedded absorption and scattering objects in the ultrasound-modulated optical signals were compared. The effects of neighboring inhomogeneity and background optical properties on the ultrasound-modulated optical signals were also studied. We analyzed the signal-to-noise ratio in the experiment and found that the major noise source is the speckle noise caused by small particle movement within the biological tissue sample. We studied this effect by incorporating a Brownian motion factor in the simulation.  相似文献   

19.
Ryu SY  Choi HY  Na J  Choi WJ  Lee BH 《Applied optics》2008,47(10):1510-1516
We demonstrate a compact all-fiber sampling probe for an optical coherence tomography (OCT) system. By forming a focusing lens directly on the tip of an optical fiber, a compact sampling probe could be implemented. To simultaneously achieve a sufficiently long working distance and a good lateral resolution, we employed a large-mode area photonic crystal fiber (PCF) and a coreless silica fiber (CSF) of the same diameters. A working distance of up to 1270 microm, a 3 dB distance range of 2210 microm, and a transverse resolution of 14.2 microm were achieved with the implemented PCF lensed fiber; these values are comparable to those obtainable with a conventional objective lens having an NA of 0.25 (10 x). The performance of the OCT system equipped with the proposed PCF lensed fiber is presented by showing the OCT images of a rat finger as a biological sample and a pearl as an in-depth sample.  相似文献   

20.
Shin SH  Javidi B 《Applied optics》2002,41(14):2644-2649
We propose a method to implement a speckle-reduced coherent three-dimensional (3D) display system by a combination of integral imaging and photorefractive volume holographic storage. The 3D real object is imaged through the microlens array and stored in the photorefractive crystal. During the reconstruction process a phase conjugate reading beam is used to minimize aberration, and a rotating diffuser located on the imaging plane of the lens array is employed to reduce the speckle noise. The speckle-reduced 3D image with a wide viewing angle can be reconstructed by use of the proposed system. Experimental results are presented and optical parameters of the proposed system are discussed in detail.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号