首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Heat transfer during oscillatory flow in a circular straight tube with a solid‐core tube inserted in its center was numerically simulated. The purpose of the solid‐core tube is to enhance axial heat transfer by increasing the lateral heat transfer effect for high frequency of the oscillatory flow. Simulation results showed that (a) axial heat transfer increases with the increasing diameter of the solid‐core tube, (b) the material of the solid‐core tube does not significantly affect axial heat transfer, and (c) efficiency based on the ratio of heat transfer to the work done is higher than that in a bundle of circular capillary tubes. © 2005 Wiley Periodicals, Inc. Heat Trans Asian Res, 35(1): 61–74, 2006; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.20094  相似文献   

2.
Fluid flow and convective heat transfer of water in sintered bronze porous plate channels was investigated numerically. The numerical simulations assumed a simple cubic structure formed by uniformly sized particles with small contact areas and a finite-thickness wall subject to a constant heat flux at the surface which mirrors the experimental setup. The permeability and inertia coefficient were calculated numerically according to the modified Darcy’s model. The numerical calculation results are in agreement with well-known correlation results. The calculated local heat transfer coefficients on the plate channel surface, which agreed well with the experimental data, increased with mass flow rate and decreased slightly along the axial direction. The convection heat transfer coefficients between the solid particles and the fluid and the volumetric heat transfer coefficients in the porous media predicted by the numerical results increase with mass flow rate and decrease with increasing particle diameter. The numerical results also illustrate the temperature difference between the solid particles and the fluid which indicates the local thermal non-equilibrium in porous media.  相似文献   

3.
LocalHeatandMassTransferforGas-SolidTwoPhaseFlowinCFBFengLu;Ming-HengShi(Dept.ofPowerEng.,SoutheastUniversity,Nanjing,210018,...  相似文献   

4.
In general heat transfer intensity between solid surface and coolant (fluid) depends on three main parameters: heat transfer coefficient, size of heat exchange surface and temperature difference between surface and fluid. Sometimes the last two parameters (surface size and temperature difference) are strictly limited due to the process or technological requirements, and only increase of heat transfer coefficient is allowed. Simplest way offering sufficient increase in heat transfer rate (heat transfer coefficient as well) is to go from the laminar fluid flow regime to the turbulent one by increasing flow velocity. In many cases it helps despite such disadvantages like more complicated fluid supply system, rise of fluid flow mass rate and growth of energy usage for pumping. But in some cases, for example, in space application, in nuclear engineering, etc. there is not allowed to use high flow velocity of coolant – gas (due to vibration danger) or to apply high mass rate of coolant – liquid (due to limitation concerning weight or mass). One of the possible solutions of that problem could be the usage of two-phase flow as a coolant. An idea to use such two-phase coolant for heat removal from the solid surface is not new. Boiling liquid (water especially), gas flow with liquid droplets and other two-phase systems are widely used for heat and mass transfer purposes in various industries like food, chemical, oil, etc. An application of such two-phase coolants has lot advantages; high value of heat transfer coefficient is one of the most important. Unfortunately nothing is ideal on the Earth. Restrictions on vibration, on coolant weight (or mass rate); necessity to generate two-phase flow separately from the heat removal place; requirements on very low coolant velocities and other constraints do not allow using such type of two-phase coolant for purposes which were mentioned above (space application especially). As a possible way out can be usage of the statically stable foam flow produced from gas (air) and surfactant solutions in liquid (water). Our previous investigations [J. Gylys, Hydrodynamics and Heat Transfer under the Cellular Foam Systems, Technologija, Kaunas, 1998] showed the solid advantages of that type of two-phase coolant, including high values of heat transfer coefficient (up to 1000 W/m2 K and more), low flow velocities (less than 1.0 m/s), small coolant density (less than 4 kg/m3), possibility to generate foam flow apart from the heat removal place, etc.This article is devoted to the experimental investigation of the staggered tube bundle heat transfer to the vertical upward and downward statically stable foam flow. The investigations were provided within the laminar regime of foam flow. The dependency of the tube bundle heat transfer on the foam flow velocity, flow direction and volumetric void fraction were analyzed. In addition to this, the influence of tube position in the bundle was investigated also. Investigation shows that the regularities of the tube bundle heat transfer to the vertical foam flow differ from the one-phase (gas or liquid) flow heat transfer peculiarities. It was showed that the heat transfer intensity of the staggered tube bundle to the foam flow is much higher (from 25 to 100 times) than that for the one-phase airflow under the same conditions (flow velocity). The results of the investigations were generalized using criterion equations, which can be applied for the calculation and design of the statically stable foam heat exchangers with the staggered tube bundles.  相似文献   

5.
Steady heat transfer enhancement has been studied in helically coiled-tube heat exchangers. The outer side of the wall of the heat exchanger contains a helical corrugation which makes a helical rib on the inner side of the tube wall to induce additional swirling motion of fluid particles. Numerical calculations have been carried out to examine different geometrical parameters and the impact of flow and thermal boundary conditions for the heat transfer rate in laminar and transitional flow regimes. Calculated results have been compared to existing empirical formulas and experimental tests to investigate the validity of the numerical results in case of common helical tube heat exchanger and additionally results of the numerical computation of corrugated straight tubes for laminar and transition flow have been validated with experimental tests available in the literature. Comparison of the flow and temperature fields in case of common helical tube and the coil with spirally corrugated wall configuration are discussed. Heat exchanger coils with helically corrugated wall configuration show 80–100% increase for the inner side heat transfer rate due to the additionally developed swirling motion while the relative pressure drop is 10–600% larger compared to the common helically coiled heat exchangers. New empirical correlation has been proposed for the fully developed inner side heat transfer prediction in case of helically corrugated wall configuration.  相似文献   

6.
In this study, a two‐?uid Eulerian–Eulerian model has been carried out applying the kinetic theory of granular flow (KTGF) to study the hydrodynamics and heat transfer behavior of a fluidized bed reactor simultaneously. The effects of different gas–solid flow regimes on the operating conditions and heat transfer rate between the hot air and two types of low and high‐density inert particles are investigated in a fluidized bed dryer. Different gas–solid flow regimes for wood and glass particles of groups A, B, and D of Geldart's classification are simulated to introduce the most optimal flow regime in terms of heat transfer rate and operating costs. The compromise between the heating rate, the height required for the reactor, and the ratio of the final mass to the initial mass of solid particles, which specifies the need for a cyclone separator showed that the bubbling regime of Geldart B powder for low‐density particles and the turbulent regime of Geldart D powder or bubbling regime of Geldart B powder for high‐density particles are the optimal operating conditions and flow regimes. Furthermore, it was concluded that the convective heat transfer is the dominant mechanism, which increases with increasing the air velocity and decreasing the particle diameter in each group.  相似文献   

7.
The field synergy equation for steady laminar convection heat transfer was derived by conditional variation calculus based on the least dissipation of heat transport potential capacity. The optimum velocity field with the best heat transfer performance and least flow resistance increase can be obtained by solving the synergy equation. The numerical simulation of laminar convection heat transfer in a straight circular tube shows that the multi-longitudinal vortex flow in the tube is the flow pattern that enhances the heat transfer enormously. Based on this result, a novel enhanced heat transfer tube, the discrete double-inclined ribs tube (DDIR-tube), is developed. The flow field of the DDIR-tube is similar to the optimal velocity field. The experimental results show that the DDIR-tube has better comprehensive heat transfer performance than the current heat transfer enhancement tubes. The present work indicates that new heat transfer enhancement techniques could be developed according to the optimum velocity field.  相似文献   

8.
Experimental study was performed on the convective heat transfer of gaseous solid suspension flow within helically coiled circular tube. The results show that the increase in heat transfer is greater than that due to the simple contribution of the increased heat capacity as the flowing media. This suggests that the addition of the suspended phase into the flows with curved stream lines can bring about the substantial reduction in the convective heat transfer resistance in the vicinity of the channel walls of the outer curvature portion. However, slight decrease in mixture Stanton number is also observed at the slight loading ratio region and the sublayer disturbing effect is seen to be gradually saturated at the higher loading region. Accordingly, overall reduction in the turbulence level also exists in the turbulent core of the flow and it is expected that there is an optimum solid loading ratio at which the viscous sublayer disturbing effect on the overall heat transfer performance is most effective.  相似文献   

9.
Three-dimensional simulations of four louver-tube junction geometries are performed to investigate the effect on louver and tube friction and heat transfer characteristics. Three Reynolds numbers, 300, 600 and 1100, based on bulk velocity and louver pitch are calculated. Strong three-dimensionality exists in the flow structure in the region where the angled louver transitions to a flat landing adjoining the tube surface, whereas the flow on the angled louver far from the tube surface is nominally two-dimensional. Due to the small spatial extent of the transition region, its overall impact on louver heat transfer is limited, but the strong unsteady flow acceleration on the top louver surface augments the heat transfer coefficient on the tube surface by over 100%. In spite of the augmentation, the presence of the tube lowers the overall Nusselt number of the heat exchanger between 25% and 30%. Comparisons with correlations derived from experiments on full heat exchanger cores show that computational modeling of a small subsystem can be used reliably to extract performance data for the full heat exchanger.  相似文献   

10.
ABSTRACT

Conjugate heat transfer to supercritical CO2 in membrane helical coiled tube heat exchangers has been numerically investigated in the present study. The purpose is to provide detailed information on the conjugate heat transfer behavior for a better understanding of the abnormal heat transfer mechanism of supercritical fluid. It could be concluded that the supercritical fluid mass flux and vertical/horizontal placement would significantly affect the abnormal heat transfer phenomenon in the tube side. The flow field of supercritical fluid is affected by both the buoyancy and centrifugal force in the conjugate heat transfer process. The local wall temperature and heat transfer coefficient in the tube side would rise and fall periodically for the horizontal heat exchanger, but this phenomenon will gradually disappear with the increase of the mass flow rate or fluid temperature in the tube side. The dual effects of buoyancy force and centrifugal force lead to the deflection of the second flow direction for the vertical placement, which further results in the heat transfer deterioration region on the top-generatrix wall for the downward flow being larger than that for the upward flow.  相似文献   

11.
An experimental study of suspensions of 120 μ and 480 μ mean-diameter glass particles in turbulent air flow is presented. Particle trajectories were recorded photographically and local velocities were deduced. Trajectories were linear and velocity distributions were uniform. Heat transfer between solid and gas was studied, cold particles being introduced into a warm air flow. Heat transfer coefficients were calculated from mean air temperature measurements at different points along the tube. Theoretical analysis shows that the problem may be solved by means of a simplified one-dimensional model. This model is based on a drag coefficient, and a heat transfer coefficient between air and particles. Using heat transfer and drag coefficients for a single sphere in steady flow to calculate lengthwise variation of mean velocity and air temperature, good agreement is found with the experimental results.  相似文献   

12.
An analysis has been performed on the heat transfer with thermal radiation by flowing gaseous suspensions of solid and/or liquid fine particles in an inlet section of circular tube. The examination of the results on temperature profiles of both phases and heat transfer parameters illustrates that the multiphase medium is pertinent to heat transfer at high and extremely high temperatures because of the absorption behavior of the dispersed phase for thermal radiation and the results are summarized for wide ranges of parameters such as loading ratio, heat transfer characteristics between two phases, optical thickness of a duct, interaction parameter of conduction with radiation, etc. The interactions between the convection to fluid and the radiation are. thereafter, examined in some details.  相似文献   

13.
The objective of this review is to assess and analyze the literature on the effect of tube diameter on heat transfer at super-critical (SC) pressures. The review is based on SC heat transfer data obtained in tubes with a diameter range of 3.18 to 38.1 mm, cooled by carbon dioxide, water, R-22, and R-12. The majority of experimental studies show that, for the same flow conditions, the heat transfer coefficient (HTC) in the ‘normal’ heat transfer mode increases with a decrease in tube diameter. Furthermore, it was found that at SC pressures, heat transfer is more prone to deteriorate in large tube diameters. In the “deteriorated” heat transfer mode, the HTC also appears to decrease with an increase in tube diameter.  相似文献   

14.
The effects of tube bank configuration on forces and heat transfer were investigated for both two-dimensional and three-dimensional gas fluidized beds. Effective dynamic forces and heat transfer coefficients were measured for several tube bank configurations, and it was found that the average forces are smaller than for a single tube. The heat transfer coefficient can be increased by providing sufficient space for particles to descend around both sides of the tube bank. The results provide useful guidelines for optimizing the configuration of tube banks to achieve high heat transfer coefficients while reducing tube erosion due to dynamic forces.  相似文献   

15.
Experimental research was conducted to understand heat transfer characteristic of pulsating heat pipe in this paper, and the PHP is made of high quality glass capillary tube. Under different fill ratio, heat transfer rate and many other influence factors, the flow patterns were observed in the start-up, transition and stable stage. The effects of heating position on heat transfer were discussed. The experimental results indicate that no annular flow appears in top heating condition. Under different fall ratios and heat transfer rate, the flow pattern in PHP is transferred from bulk flow to semi-annular flow and annular flow, and the performance of heat transfer is improved for down heating case. The experimental results indicate that the total heat resistant of PHP is increased with fill ratio, and heat transfer rate achieves optimum at filling rate 50%. But for pulsating heat pipe with changing diameters the thermal resistance is higher than that with uniform diameters.  相似文献   

16.
In the present study, for industrial applications of large inter-coolers employed in multi-stage compressor systems the air-side laminar heat transfer and fluid flow characteristics of plain fin-and-tube heat exchangers with large number of tube rows and large diameter of the tubes are investigated numerically through three-dimensional simulations based on the SIMPLE algorithm in Cartesian coordinates. The effects of parameters such as Reynolds number, the number of tube rows, tube diameter, tube pitches and fin pitch are examined, and the variations of heat transfer due to variations of fin materials are also observed. It is found that the heat transfer and fluid flow approach fully developed conditions when the number of tube rows is greater than six, and the tube diameter as well as the fin pitch have much more significant effects than the tube pitch, and the heat transfer of high-conductivity material is larger than that of low-conductivity material especially in the high Reynolds number regime. Due to the fact that the existing correlations are not valid for large tube diameters and number of tube rows, the heat transfer and flow friction of the presented heat exchangers are correlated in the multiple forms. The correlation is so obtained that it can be used for further studies such as performance prediction or geometrical optimization.  相似文献   

17.
The two equation numerical model has been applied for parallel flow double-pipe heat exchanger filled with open cell metal foams. The model fully considered solid–fluid conjugated heat transfer process coupling heat conduction and convection in open cell metal foam solid matrix, interface wall and fluid in both inner and annular space in heat exchanger. The non-Darcy effect and the wall thickness are also taken into account. The interface wall heat flux distribution along the axial direction is predicted. The numerical model is firstly verified and then the influences of solid heat conductivity, metal foam porosity, pore density, relative heat conductivity and inner tube radius of the heat exchanger on dimensionless temperature distribution and heat transfer performance of heat exchanger are numerically studied. It is revealed that the proposed numerical model can effectively display the real physical heat transfer process in the double pipe heat exchanger. It is expected to provide useful information for the design of metal foam filled heat exchanger.  相似文献   

18.
The paper presents numerical investigations of a three fluid heat exchanger (TFHE), which is an improvement on the double pipe heat exchanger, where a helical tube is inserted in the annular space between two straight pipes. The helical tube side fluid, that is, hot water continuously transfers heat to the outer annulus side fluid and innermost tube side fluid. The heat transfer and pressure drop characteristics of the TFHE are assessed for different flow rates and inlet temperatures. With an increment in the volumetric flow rate of the helical tube side fluid and outer annulus side fluid, the overall heat transfer coefficient increases, and the effectiveness decreases for heat transfer from the helical tube side fluid to outer annulus side fluid in both parallel flow and counter flow configurations. It is also observed that with increment in the helical tube side fluid inlet temperature, the overall heat transfer coefficient and effectiveness increases for heat transfer from the helical tube side fluid to outer annulus side fluid in both flow configurations. The parameter, JF factor, has been proposed to evaluate the thermohydraulic behavior of the TFHE, where it is obtained that the behavior of the TFHE is better at a lower helical tube side fluid velocity and higher outer annulus side fluid velocity.  相似文献   

19.
基于k-ε模型,针对一种非对称横槽管换热元件,对高温高压工况下管内氦气的流动与传热进行了数值模拟研究。比较了非对称横槽管与对称横槽管的综合传热性能。同时,应用"中心复合设计"(CCD)方法对非对称横槽管的三个基本结构参数(槽间距a、槽宽b、槽深e)进行了优化设计,考察了不同结构对非对称横槽管传热性能的影响,并对其内部机理进行了初步的探讨。结果表明,非对称横槽管传热性能优于传统的对称型横槽管,最优结构参数为a12-b8-e0.6。  相似文献   

20.
In this paper, the convective heat transfer of the heat transfer oil-copper oxide nanofluid flow in horizontal smooth and microfin tubes is investigated experimentally. Using a flow control system, the flow regime is always laminar and the wall temperature is constant by using a steam tank. Pure heat transfer oil and nanofluid with the weight concentrations of 0.5%, 1% and 1.5% are used as working fluids. The results are in good agreement with the classic correlations for the pure fluid flow. Based on the results, combination use of nanoparticles and the microfin tube leads to the heat transfer enhancement up to 230%, in comparison with the base fluid flow in the smooth tube. The results are useful in the prediction of the heat transfer rate and the pressure drop in nanofluid flows.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号