首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this paper, an absorption heat transformer (AHT) with falling film of aqueous LiBr solution inside vertical spiral tubes is installed and tested. The variations of coefficient of performance (COP), thermal efficiency (Eth ), and the heat transfer coefficient of the absorber at different falling film flow rates, hot water flow rates, and operating temperatures are investigated experimentally. The results demonstrated that the coefficient of performance and thermal efficiency of the system decrease with the increase in the flow rate of LiBr solution, and the influence of flow rate of hot water on COP and Eth is insignificant. The available COP in the experiments is higher than 0.4. The heat and mass transfer coefficients of the absorber increase with the increase of the flow rate of LiBr solution, up to 400W/m2/K and 0.013 kg/m2/s (temperature of waste heat is 90°C). The heat transfer coefficient of the absorber increases with the increase of the temperature of waste heat, and decreases with the increase of the cooling water temperature. Meanwhile, the computer code ABSIM (Absorption Simulation) is used to simulate the AHT systems, and the simulated results are compared with the experimental data.  相似文献   

2.
Fouling of oils on heat exchanger surfaces and pipelines is a common problem in a variety of industrial applications. This is because the oil deposits on the heat transfer surface causes an increase in pressure drop and a decrease in heat exchanger efficiency. In the current work, oil fouling in double pipe heat exchanger was investigated and mitigated using a surface‐active agent for the flow of a dispersion fluid containing different dispersed oil fractions in water. The effect of the dispersed oil fraction (5%vol and 10%vol) and temperature (35°C‐55°C) on the oil fouling rate was studied and discussed under turbulent flow conditions for both hot and cold fluids. Different amounts of alkylbenzene sulfonate as a surfactant were added to reduce the fouling rate under turbulent flow. It was found that the fouling thermal resistance (Rf) increases when the fluid temperature decreases. The higher the dispersed oil fraction, the higher the Rf for all temperatures due to higher oil deposition. Addition of 0.2%vol to 0.5%vol of alkylbenzene sulfonate caused an appreciable reduction in Rf depending on oil fraction and Reynolds number. The mitigation percent was higher for a lower Reynolds number, reaching up to 96%.  相似文献   

3.
A theoretical study on the employment of a lithium bromide absorption heat pump in Spain, used as machine type I and aimed to produce heat at 120°C via waste heat sources at 60°C, is given in the paper. Real performance conditions are stated for each component of the machine, namely the absorber, the heat recoverer, the generator, the condenser, the solution pump, the expansion valve and the evaporator. By means of thermodynamic diagrams (p, t, x) and (h, x), the required data are obtained for calculation of the heat recovered in the evaporator Qe, and the heat delivered to the absorber Qa and to the condenser Qc, as well as the heat supplied to the generator Qg. In addition, the heat delivered by the hot solution to the cold solution in the heat recovered Qr, and the work Wp done by the solution pump are calculated. The probable COP is calculated, and values are obtained close to 1.4. The working temperature in the generator is determined; it ranges from 178 to 200°C. The heat produced by the lithium bromide absorption heat pump is 22% cheaper than the heat obtained from a cogeneration system comprising natural gas internal combustion engine and a high temperature heat pump with mechanical compression. Compared with a high temperature heat pump with mechanical compression, the heat produced by the absorption heat pump is 31% cheaper. From (h, x) and (s, x) diagrams, exergy losses for each component can be determined, and, from these results, an exergetic efficiency of 75% is obtained, which provides the quality index of absorption cycle.  相似文献   

4.
An experimental study has been carried out to determine the effect on the heat transfer and friction characteristics of an equilateral triangular solar air heater duct using inclined continuous ribs as roughness element on the absorber plate. The experimental study encompasses the range of Reynolds numbers from 5600 to 28,000, relative roughness height (e/Dh) 0.021–0.043, relative roughness pitch (p/e) 8–16 and angle of attack (α ) 30–60°. The duct has an aspect ratio (W/H) of 1.15. The effect of flow parameters and roughness parameters on heat transfer and friction factor is discussed. The thermohydraulic performance parameter has been determined for the given range of flow parameters and roughness parameters.  相似文献   

5.
We have studied the enhancement of heat transfer by vortex generators. Experiments were performed on rectangular‐type vortex generators mounted on a parallel‐plate heater, and the heat transfer coefficient of the heater surface and pressure drop in the duct were measured. These measurements indicated that a rectangular vortex generator (called a double‐inclined winglet), with inclination angle of the vortex generator surface to the heater surface (β) at 60°, and the attack angle to the flow direction (γ) at 45°, maximizes the local Nusselt number of the heater surface. It was also found that a group of double‐inclined winglets has an optimal arrangement in a winglet array, longitudinal pitch and transverse pitch, that maximizes the ratio [Colburn's dimensionless heat transfer coefficient JH]/[friction factor f]. The results of numerical calculations showed that the double‐inclined winglet was superior to the conventional rectangular vortex generator in heat transfer. © 2003 Wiley Periodicals, Inc. Heat Trans Asian Res, 32(3): 253–267, 2003; Published online in Wiley InterScience ( www.interscience.wiley.com ). DOI 10.1002/htj.10089  相似文献   

6.
This paper presents an investigation on using an ammonia refrigerant with liquid/solid absorbents in an absorber heat recovery cycle where heat released during the absorption process is used to heat up the strong solution coming out of the absorber, thereby reducing the generator heat input and hence improving the coefficient of performance. A comparative thermodynamic study is made with NH3-H2O and NH3-LiNO3 pairs as working fluids for both conventional absorption and absorber heat recovery systems. It is found that an improvement of about 10 per cent in COP for the absorber heat recovery cycle is achieved over the conventional absorption cycle and the NH3-LiNO3 system yields a higher COP than for NH3-H2O over a wide range of generator temperatures and condenser/absorber temperatures. A detailed parametric study is also presented in this paper.  相似文献   

7.
Minsoo Kim 《传热工程》2019,40(12):973-984
ABSTRACT

The present study investigated the evaporation heat transfer coefficients of R-446A, as a low global warming potential alternative refrigerant to R-410A. The evaporation heat transfer coefficients were obtained by measuring the wall temperature of a straight stainless tube and refrigerant pressure. The heat transfer coefficients were measured for the quality range from 0.05 to 0.95, the mass flux from 100 to 400 kg/m2s, heat flux from 10 to 30 kW/m2, and saturation temperature from 5 to 10°C. The evaporation heat transfer coefficient of R-410A was verified by comparing the measured evaporation heat transfer coefficient with the value predicted by the existing correlation. The evaporation heat transfer coefficient of R-446A was measured using a proven experimental apparatus. When the heat flux was 10 kW/m2, the evaporation heat transfer coefficient of R-446A was always higher than that of R-410A. But, when the heat flux was 30 kW/m2, the evaporation heat transfer coefficient of R-446A was measured to be lower than that of R-410A near the dry-out point. The effect of the tube diameter on the R-446A evaporation heat transfer coefficient was negligible. The effect of saturation pressure on the evaporation heat transfer coefficient was prominent in the low quality region where the nucleate boiling was dominant.  相似文献   

8.
Forced convection in channels filled with packed beads with internal heat source was numerically analyzed by using the extended Darcy model for the flow and energy conservation equations with nonthermal equilibrium (NTE). The temperature difference between the matrix and fluid phases was discussed with three dimensionless parameters (Rep, H/dp, and ks/kf). It is concluded that the thermal equilibrium assumption may be adopted for the situation when the solid conduction dominated over the convection or when the heat transfer coefficient between the two phases is large at large Rep. The Nusselt number at the wall with the variation of Rep for different ks/kf was also investigated. © 2001 Scripta Technica, Heat Trans Asian Res, 30(3): 213–221, 2001  相似文献   

9.
For utilization of the residual heat of flue gas to drive the absorption chillers,a lithium-bromide
falling film in vertical tube type generator is presented.A mathematical model was developed to
simulate the heat and mass coupled problem of laminar falling film evaporation in vertical tube.In the
model,the factor of mass transfer was taken into account in heat transfer performance calculation.The
temperature and concentration fields were calculated.Some tests were conducted for the factors
such as Re number,heating flux,the inlet concentration and operating pressure which can affect the
heat and mass transfer performance in laminar falling film evaporation.The heat transfer performance is
enhanced with the increasing of heat flux.An increasing inlet concentration can weaken the heat
transfer performance.The operating pressure hardly affects on heat and mass transfer.The bigger inlet
Re number means weaker heat transfer effects and stronger mass transfer.The mass transfer
obviously restrains the heat transfer in the falling film solution.The relation between dimensionless
heat transfer coefficient and the inlet Re number is obtained.  相似文献   

10.
P. Lin  R.Z. Wang  Z.Z. Xia 《Renewable Energy》2011,36(5):1401-1412
Two-stage air-cooled ammonia–water absorption refrigeration system could make good use of low-grade solar thermal energy to produce cooling effect. The system simulation results show that thermal COP is 0.34 and electrical COP is 26 under a typical summer condition with 85 °C hot water supplied from solar collector. System performances under variable working conditions are also analyzed. Circular finned tube bundles are selected to build the air-cooled equipment. The condenser should be arranged in the front to get an optimum system performance. The mathematical model of the two-stage air-cooled absorber considering simultaneous heat and mass transfer processes is developed. Low pressure absorber should be arranged in front of middle pressure absorber to minimize the absorption length. Configuration of the air-cooled equipment is suggested for a 5 kW cooling capacity system. Temperature and concentration profiles along the finned tube length show that mass transfer resistance mainly exists in liquid phase while heat transfer resistance mainly exists in cooling air side. The impacts on system refrigeration capacities related to absorption behaviors under variable working conditions are also investigated. Both cycle analysis and absorption performances show that two-stage air-cooled ammonia–water absorption chiller is technically feasible in practical solar cooling applications.  相似文献   

11.
This paper presents simple thermal analysis to evaluate the natural convective heat transfer coefficient, hc12 for a trapezoidal absorber plate-inner glass cover enclosure of a double-glazed box-type solar cooker. Several indoor simulation experiments in steady state conditions have been performed to measure the temperatures of absorber plate, inner and outer glass covers, ambient air, electrical input supply and wind speed. The experimental data has been correlated by an equation of the form, Nu = CRan. The values of the constants C and n, obtained by linear regression analysis are used to calculate the convective heat transfer coefficient. The heat transfer analysis predicts that hc12 varies from 4.84 to 6.23 W m−2 oC−1 for the absorber plate temperature from 54 to 141 oC. The results of hc12 are compared with those of rectangular enclosure for the same absorber-inner glass cover temperatures and gap spacing. The study reveals that the values of convective heat transfer coefficient and top heat loss coefficient for rectangular enclosure are lower by 31–35% and 7% respectively.  相似文献   

12.
The evaporation heat transfer experiments were conducted with an oblong shell and plate heat exchanger without oil in the refrigerant loop using R-410A, a mixture of 50 wt% R-32 and 50 wt% R-125 that exhibits azeotropic behavior. An experimental refrigerant loop has been established to measure the evaporation heat transfer coefficient h r of R-410A in a vertical oblong shell and plate heat exchanger. Four vertical counter-flow channels were formed in the oblong shell and plate heat exchanger by four plates having a corrugated trapezoid shape of a 45° chevron angle. The upflow of the boiling R-410A in one channel receives heat from the hot downflow of water in the other channel. The effects of the refrigerant mass flux, average heat flux, refrigerant saturation temperature, and vapor quality of R-410A on the measured data were explored in detail. The results indicate that a rise in the refrigerant mass flux causes an increase in the h r . Raising the imposed wall heat flux was found to slightly improve h r . Finally, at a higher refrigerant saturation temperature, the h r is found to be lower. Based on the present data, an empirical correlation of the evaporation heat transfer coefficient was proposed.  相似文献   

13.
In this study, the local characteristics of pressure drop and heat transfer were investigated experimentally for carbon dioxide condensation in a multi-port extruded aluminum test section, which had 10 circular channels each with 1.31 mm inner diameter. The CO2 was cooled with cooling water flow inside the copper blocks that were attached at both sides of the test section. The temperatures at the outer surface of the test section were measured with 24 K-type thermocouples embedded in the upper and lower surfaces along the length. Local heat fluxes were measured with 12 heat flux sensors to estimate the local enthalpies, temperatures and heat transfer coefficients. Bulk mean temperatures of CO2 at the inlet and outlet of the test section were measured with 2 K-type thermocouples. The measurements were performed for the pressure ranged from 6.48 to 7.3 MPa, inlet temperature of CO2 from 21.63 to 31.33℃, heat flux from 1.10 to 8.12 kW/m2, mass velocity from 123.2 to 315.2 kg/m2s, and vapor quality from 0 to 1. The results indicate that pressure drop is very small along the test section, heat transfer coefficient in the two-phase region is higher than that in the single-phase, and mass velocity has important effect on condensation heat transfer characteristics. In addition, experimental data were compared with previous correlations and large discrepancies were observed.  相似文献   

14.
This paper examines experimentally the effect of jet vortex technology on enhancing the heat transfer rate within a double pipe heat exchanger by supplying the heat exchanger with water at different vortex strengths. A vortex generator with special inclined holes with different inlet angles was designed, manufactured, and integrated within the heat exchanger. In this study, four levels of Reynolds number for hot water in the annulus (Reh) were used, namely, 10,000; 14,500; 18,030; and 19,600. Similarly, four levels of Reynolds number for cold water in the inner tube (Rec) were used, namely, 12,000; 17,500; 22,500; and 29,000. As for the inlet flow angle (θ), four different levels were selected, namely, 0°, 30°, 45°, and 60°. The temperature along the heat exchanger was measured utilizing 34 thermocouples installed along the heat exchanger. It was found that increasing the inlet flow angle (θ) and/or the Reynolds number results in an increase in the local Nusselt number, the overall heat transfer coefficient, and the ratio of friction factor. It is revealed that the percentage increase in the average Nusselt number due to swirl flow compared to axial flow was 10%, 40%, and 82% for an inlet flow angle of 30°, 45°, and 60°, respectively.  相似文献   

15.
Specific heat and thermal conductivity are important thermal properties of high-temperature heat transfer fluids and thermal storage materials for supercritical solar power plants. In the present work, nanofluids composed of ternary carbonate Li2CO3-K2CO3-Na2CO3 (4:4:2, mass ratio) and 1.0 wt.% carbon nanotubes (CNT) were prepared to obtain high-temperature heat transfer and storage media with enhanced specific heat and thermal conductivity. The dispersion of CNTs in the nanofluids was tuned by changing the evaporation temperature (100, 140, 180 and 220 °C) and adding surfactants such as sodium dodecyl benzene sulfonate (SDBS), sodium dodecyl sulfate (SDS), or gum Arabic (GA). The results showed that GA and SDS facilitate good dispersion of CNT in nanofluids at the evaporation temperatures of 140 °C and 180 °C, resulting in the formation of more needle-like nanostructures. The higher increase in the specific heat and thermal conductivity of the nanofluids with SDS at 500 °C was 78.3% and 149.2%, respectively. Additionally, the specific heat of as-prepared ternary carbonate nanofluids exhibits a good thermal stability after 30 cycles of thermal shock experiments.  相似文献   

16.
Experimental heat transfer studies during condensation of pure R-134a vapor inside a single microfin tube have been carried out. The microfin tube has been provided with different tube inclination angles of the direction of fluid flow from horizontal, α. The data are acquired for seven different tube inclinations, α, in a range of −90 to +90° and three mass velocities of 54, 81, and 107 kg/m2-s for each inclination angle during condensation of R-134a vapor. The experimental results indicate that the tube inclination angle of, α, affects the condensation heat transfer coefficient in a significant manner. The highest heat transfer coefficient is attained at inclination angle of α = +30°. The effect of inclination angle, α, on heat transfer coefficient, h, is more prominent at low vapor quality and mass velocity. A correlation has also been developed to predict the condensing side heat transfer coefficient for different vapor qualities and mass velocities.  相似文献   

17.
The present study exemplifies the comprehensive thermal analysis to compare and contrast ammonia‐lithium nitrate (NH3‐LiNO3) and ammonia‐sodiumthiocynate (NH3‐NaSCN) absorption systems with and without incorporation of nanoparticles. A well‐mixed solution of copper oxide/water (CuO/H2O) nanofluid is considered inside a flat‐plate collector linked to an absorption chiller to produce 15‐kW refrigeration at ?5°C evaporator temperature. Enhancements in heat transfer coefficient, thermal efficiency, and useful heat gain of the collector are evaluated, and the effect of these achievements on the performance of both absorption chillers have been determined for different source temperatures. A maximum 121.7% enhancement is found in the heat transfer coefficient with the application of the nanofluid at 2% nanoparticle concentration. The maximum coefficient of performance observed for the NH3‐NaSCN chiller is 0.12% higher than that for the NH3‐LiNO3 chiller at 0°C evaporator temperature. Contradictory to this, the average system coefficient of performance of the NH3‐LiNO3 absorption system has been found 5.51% higher than that of the NH3‐NaSCN system at the same evaporator temperature. Moreover, the application of the nanofluid enhanced the performance of the NH3‐NaSCN and NH3‐LiNO3 systems by 2.70% and 1.50%, respectively, for lower generator temperature and becomes almost the same at higher temperatures, which altogether recommends the flat‐plate collector–coupled NH3‐LiNO3 absorption system be integrated with a nanofluid.  相似文献   

18.
Abstract

By using unique experimental techniques and the careful construction of an experimental apparatus, the characteristics of the local heat transfer were investigated using the condensing R134a two-phase flow in horizontal single mini-channels. The circular channels (D h = 0.493, 0.691, and 1.067 mm) and rectangular channels (Aspect Ratio = 1.0; D h = 0.494, 0.658, and 0.972 mm) were tested and compared. Tests were performed for a mass flux of 100, 200, 400, and 600 kg/m2s, a heat flux of 5 to 20 kW/m2, and a saturation temperature of 40°C. In this study, the effect of heat flux, mass flux, vapor qualities, hydraulic diameter, and channel geometry on flow condensation were investigated, and the experimental local condensation heat transfer coefficients are shown. The experimental data of condensation Nusselt number are compared with existing correlations.  相似文献   

19.
Absorption of solar radiation in the glass cover(s) of a flat plate solar collector increases the temperature of cover(s) and hence changes the values of convective and radiative heat transfer coefficients. The governing equations for the case of single as well as double glazed collector have been solved for inner and outer surface temperatures of glass cover(s) with/without including the effect of absorption of solar radiation in the glass cover(s), with appropriate boundary conditions. The effects of absorption of solar radiation on inner and outer surface temperatures and consequently on convective and radiative heat transfer coefficients have been studied over a wide range of the independent variables. The values of glass cover temperatures obtained from numerical solutions of heat balance equations with and without including the effect of absorption of solar radiation in the glass cover(s) are compared. For a single glazed collector the increase in glass cover temperature due to absorption of solar radiation could be as high as 6°. The increase in temperatures of first and second glass covers of a double glazed collector could be as high as 14° and 11°, respectively. The effect on the convective heat transfer coefficient between the absorber plate and the first glass cover is substantial. The difference in the values of the convective heat transfer coefficients between the absorber plate and the first glass cover (hcp1) of a double glazed collector for the two cases: (i) including the effect of absorption and (ii) neglecting the effect of absorption in glass cover, could be as high as 49%. Correlations for computing the temperatures of inner and outer surfaces of the glass cover(s) of single and double glazed flat plate collectors are developed. The relations developed enable incorporation of the effect of absorption of solar radiation in glass cover(s) in the relations for inner and outer surface temperatures in a simple manner. By making use of the relations developed for inner and outer surface temperatures of glass cover(s) the convective and radiative heat transfer coefficients can be calculated so close to those obtained by making use of surface temperatures of glass cover(s) obtained by numerical solutions of heat balance equations that numerical solutions of heat balance equations are not required.  相似文献   

20.
Nucleate boiling heat transfer coefficients of ammonia/water mixtures have been measured when a surface‐active agent was added into the mixtures. The experiment has been carried out on a horizontal heated wire at a pressure of 0.4 MPa. The effect of concentration of the ammonia and the surface‐active agent on the coefficients was investigated experimentally for the ammonia fractions C = 0.3 and 0.7 and the surfactant concentration CS = 0 to 3500 ppm. The result shows that just after onset of boiling the nucleate boiling heat transfer coefficient enhances at the lower ammonia fraction i.e., C = 0.3. It was found that the enhancement effect by the surface‐active agent disappeared when the surfactant concentration is more than 1000 ppm at an ammonia fraction C = 0.3. It is also shown that the generated heat of mixing near the vaporBliquid interface can be removed easily and the pressure and temperature in the system can be controlled easily by placing a cooling pipe on the vaporBliquid interface, resulting in improvement of accuracy in measuring the heat transfer coefficients. We correlated the effect of the surfactant on the heat transfer coefficient using the improved measurement data in the current paper. 8 2010 Wiley Periodicals, Inc. Heat Trans Asian Res; Published online in Wiley Online Library ( wileyonlinelibrary.com ). DOI 10.1002/htj.20328  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号