首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The purpose of this study was to compare total‐etch, self‐etch, and selective etching techniques on the marginal microleakage of Class V composite restorations prepared by Er:YAG laser and bur. Class V cavities prepared on both buccal and lingual surfaces of 30 premolars by Er:YAG laser or bur and divided into six groups. The occlusal margins were in enamel, and the cervical margins were in cementum. Group‐1: bur preparation(bp)+Adper Single Bond 2 (ASB)+Filtek Z550 (FZ); Group‐2: laser preparation(lp)+(ASB)+(FZ); Group‐3: bp + Clearfil S3 Bond Plus (CSBP)+(FZ); Group‐4: lp+(CSBP) (FZ); Group‐5: bp + acid etching+(CSBP)+(FZ); Group‐6: lp + acid etching+(CSBP)+(FZ). All teeth were stored in distilled water at 37°C for 24 hr, and then thermocycled 1000 times (5–55°C). Five teeth from each group were chosen for the microleakage investigation, and two teeth for the scanning electron microscope evaluation. Teeth which were prepared for the microleakage test were immersed in .5% methylene blue dye for 24 hr. After immersion, the teeth were sectioned and observed under a stereomicroscope for dye penetration. Data were analyzed using Kruskal–Wallis and Mann–Whitney U tests (p < .05). More microleakage was observed in the cervical regions compared to the occlusal regions in Groups 3, 5, and 6, respectively (p < .05). There is no statistically significant difference in Groups 1, 2, and 4, in terms of cervical regions versus occlusal regions (p > .05). No significant differences were observed among any groups in terms of occlusal and cervical surfaces, separately (p > .05). Different etching techniques did not influence microleakage of Class V restorations prepared by Er:YAG laser and bur.  相似文献   

2.
This study compares the effect of different mouthwashes that have been recommended during the Coronavirus disease 2019 (COVID-19) pandemic on shear bond strength (SBS) of universal adhesive to enamel in regards to self-etch (SE) and etch-and-rinse (ER) modes. Flat enamel surfaces were obtained from 100 sound human maxillary central incisors. They were randomly allocated to five groups according to the different mouthwashes (no mouthwash/control [Ctrl], 0.2% chlorhexidine 1.5% hydrogen peroxide [H2O2], 0.2% povidone-iodine [PVP-I], Listerine [L]), and adhesive application modes (ER and SE) (n = 10). After the application of a universal adhesive (single bond universal), composite resin (Filtek Z250) was bonded by a cylinder-shaped mold (height: 2 mm, diameter: 2.4 mm). They were subjected to SBS test using a universal testing machine (AGS-X, Shimadzu Corp.) (crosshead speed: 1 mm/min). The resin–enamel interfaces were observed with a scanning electron microscope (SEM). The semiquantitative chemical microanalyses were performed with energy-dispersive spectroscopy (EDS). The data were statistically analyzed by two-way analysis of variance and Bonferroni test (p < .05). In SE mode, Group Ctrl revealed significantly higher SBS than all mouthwash groups (p < .05). In ER mode, Group Ctrl showed significantly higher SBS than H2O2 and PVP-I groups (p < .05). ER mode caused significantly higher SBS than SE mode in all mouthwash groups (p < .05). The SEM observations highlighted that Group Ctrl had a regular and intact hybrid layer with resin tag formation while the H2O2 and PVP-I groups exhibited a thin hybrid layer in both modes. EDS analysis indicated that in SE mode, all mouthwash groups presented increased O content compared to Group Ctrl. H2O2 and PVP-I that were suggested for preprocedural use during the COVID-19 pandemic, reduced the enamel bond strength of the universal adhesive in ER mode.  相似文献   

3.
The aim of this article is to compare the effects of 1.5 T and 3 T MRI on microleakage of amalgam restorations. A total of 90 extracted molar teeth were used in this study. Amalgam was used to restore standard Class V preparations (5 × 3 × 2 mm). Following the restoration, the teeth were divided into three groups according to magnetic resonance imaging (MRI) protocol (Group I: Control, Group II: 1.5 T MRI, and Group III: 3 T MRI). A total of 6,000 thermal cycles at 5°C–55°C were applied on all samples. Microleakage values were measured in millimeters using the ImageJ program. Microleakage values were higher in the gingival region compared to the occlusal region in all groups and the differences were statistically significant (p < .05). Microleakage values were not statistically different among the groups in the occlusal region (p > .05), while there were statistically significant differences among the groups with respect to microleakage values in the gingival region (p < .01). The highest mean microleakage amount in the gingival region was measured in Group III (1.192 ± 0.941 mm). This was followed by Group II (0.519 ± 0.813 mm) and Group I (0.347 ± 0.726 mm), respectively. Within the limitations of this in vitro study, we observed that higher microleakage values in amalgam restored teeth in which were exposed to MRI procedure. We also found that the teeth exposed to the stronger magnetic field showed higher microleakage amount.  相似文献   

4.
This study investigated the effects of fumaric acid on push‐out bond strength when applied to dentin surfaces and fiber posts. The root canals of 60 mandibular premolar teeth were instrumented and obturated. After removing two thirds of filling material, teeth were prepared according to six randomized groups (n = 10/group) defined by two fiber post surface treatments (0.7% fumaric acid or 9% hydrofluoric acid) and three dentin conditioning treatments [control (no conditioning); 17% ethylenediamine tetraacetic acid (EDTA); or 0.7% fumaric acid]. After fiber post‐cementation, three 1‐mm thick discs were obtained from each tooth by transverse sectioning, and each disc underwent push‐out bond strength testing. Data were analyzed with a one‐way analyses of variance (anova ) and t tests; p < .05 was considered statistically significant. Failure modes were determined by stereomicroscopy, and the surface characteristics of dentin and fiber posts were observed by scanning electron microscopy. Push‐out bond strength was greater for the group in which the post surface treated with hydrofluoric acid and the dentin surface treated with fumaric acid than the nontreated dentin and hydrofluoric acid‐treated post group (p < .05). There were no significant differences between other comparison pairs (p > .05). A combination of fumaric acid dentin conditioning and hydrofluoric acid fiber post treatment strengthened the bonding ability of fiber posts.  相似文献   

5.
This study aimed to evaluate the microleakage of a universal adhesive's different application modes incorporated with Er,Cr:YSGG laser on Class V resin composite restorations. Sound human molar teeth (n = 30) were used for microleakage evaluations. Specimens with 60 standardized Class V cavities were divided into five groups according to the adhesive modes of universal adhesive, Adhese Universal (n = 12). Group 1‐etch‐and‐rinse mode with phosphoric acid; Group 2‐etch‐and‐rinse mode with Er,Cr:YSGG laser; Group 3‐selective‐etch mode with phosphoric acid; Group 4‐selective‐etch mode with Er,Cr:YSGG laser; Group 5‐self‐etch. After restorations were performed with a resin composite, Tetric N‐Ceram, the specimens were polished and subjected to thermocycling (10,000X). Following immersion in 0.5% basic fuschin for a day, the teeth were sectioned and the degree of microleakage was determined along the tooth‐resin composite interface using a light microscopy(40X). Five specimens from each group were examined by scanning electron microscopy. The Kruskal–Wallis, Siegel Castello, and Wilcoxon tests were used for statistical analyses (α = .05). At the enamel margins, significant differences were obtained among the groups (p < .05). Significantly higher microleakage scores were detected in Group 5 in comparison with Groups 1, 2, and 3. There were no significant differences between different adhesive strategies at the dentin margins (p > .05). While analyzing enamel and dentin microleakage scores, no statistically significant differences were observed in Groups 4 and 5 (p > .05). The laser application time and the adhesive modes of universal adhesives could affect the microleakage at the enamel margins. Different adhesive modes of universal adhesives combined with laser etching had no influence on the microleakage scores of dentin margins.  相似文献   

6.
This study compared the performance of a glass ionomer (GC Gold Label 1, GIC) as a fiber post cementation system for glass fiber posts with a self‐adhesive resin cement (Relyx U200, RUC) and a conventional resin cement system (Scotchbond Muli‐Purpose and Relyx ARC, RAC). Thirty endodontically treated canines were randomly divided in three groups (n = 10), according to the fiber post cementation system: (RAC)—Scotchbond Multi‐Purpose and Relyx X ARC; (RUC)—Relyx U200 and (GIC)—GC Gold Label 1 Luting & Lining. Rhodamine was incorporated into the cementation system prior to the fiber post cementation. After glass fiber post cementation, roots were incubated in artificial saliva for 6 months. After that, specimens from the cervical, middle, and apical thirds of the post space were prepared and analyzed using a push‐out bond strength test and confocal laser microscopy. ANOVA one way and Tukey tests showed that GIC and RUC demonstrated similar push‐out bond strength values, independently of the post space third (p > .05); however, values were greater than those shown by RAC (p < .05). For dentin penetrability, GIC and RUC also had similar results (p > 0.05) and lower than RAC (p < 0.05). Inside the root canal, the cementation system using glass ionomer cement (GC Gold Label 1 Luting & Lining) has similar push‐out bond strength to the self‐adhesive resin cement (Relyx U200) and these were higher than the conventional resin (Relyx ARC), despite its higher dentin penetrability.  相似文献   

7.
Oxalate‐based products are effective against dentine sensitivity and have been studied as an option to improve long‐term adhesive bonding strength. Our aim was to evaluate the effect of potassium oxalate on the microtensile bond strength (µTBS) of the dentin/resin interface after 24 h, 1, and 6 years. Dentin on the occlusal surface of 16 human premolars was exposed and etched with 35% phosphoric acid. The teeth were divided into four groups. Two groups received 3% monohydrated potassium oxalate and the following adhesive systems and composites: Adper Scotchbond Multipurpose + FiltekZ350 (3M/ESPE) and Prime & Bond NT + Esthet‐X (Dentsply). Two control groups did not receive potassium oxalate. Teeth were cut into sticks and kept in distilled water at 37°C for 24 h, 1, and 6 years. The sticks underwent µTBS testing after storage. ANOVA, Tukey's post hoc test, and paired t test were used to compare storage times (α = 0.05). The fracture mode of the specimens was classified under a stereomicroscope (40×). Morphology of the hybrid layer and the fracture pattern were observed with scanning electronic microscopy (SEM). Mean µTBS was high at 24 h and decreased after 1 and 6 years. After 6 years, the mean µTBS values were similar with no statistically significant difference between the groups (p = .121). SEM images showed proper dentin hybridization. Dentin pretreatment with potassium oxalate did not affect hybrid layer formation, but bond strength decreased over time after 24 h. Therefore, the clinical use of potassium oxalate to increase dentin bond durability is not indicated.  相似文献   

8.
The purpose of this study was to evaluate age‐ and sex‐related changes in the anatomical relationships between the roots of the molars and premolars and the mandibular canal using cone‐beam computed tomography (CBCT) images. A total of 243 patients (116 males, 127 females) aged 16–83 years for whom previous CBCT scans were available were enrolled in this study. The patients were subcategorized by sex and age (Group I, <21 years; Group II, 21–40 years; and Group III, >40 years). The distances between the mandibular canal and the molars and premolars were measured. The mandibular canal was significantly closer to the root apices of the second and third molars than to the apices of other evaluated teeth (p < 0.05). All measurements were significantly higher in male than in female subjects (p < 0.05). Group I subjects exhibited significantly shorter distances between the mandibular canal and root apices of the first and second premolars, and the molars, than those of Group II and III subjects (p < 0.05). Direct contact relationships were found in 1.6%, 3.3%, 3.3%, 16%, and 32.2% of teeth (running from the first premolar to the third molar, respectively). Age and sex influenced the anatomical relationships between mandibular teeth and the mandibular canal, and these should be considered when planning endodontic and surgical procedures to avoid potential nerve injury.  相似文献   

9.
The aim of this study was to evaluate the combined effect of MTAD and photon‐induced photoacoustic streaming (PIPS) technique on the smear layer removal and the bond strength of glass fiber post. Fifty‐five human mandibular premolars were chosen. After root canal therapy and post space preparation, the teeth were equally divided to five groups according to the methods of root‐dentin pretreatment: G1: distilled water (control); G2: 2.5% NaOCl+17% EDTA; G3: MTAD; G4: PIPS; G5: MTAD+PIPS. One sample was randomly selected from each group, and scanning electron microscope (SEM) was used to observe the microscopic morphology of the coronal, middle and apical level of the root‐dentin. The remaining ten samples from each group were glued to glass fiber posts, and the bond strength was assessed by push‐out test. SEM evaluation showed that the most complete smear layer removal was found in MTAD + PIPS group, especially in coronal third. Push‐out test results exhibited that there was a statistically significant interaction between the experimental groups and root canal third (p < .0005). Significant differences could be found among five groups (p < .05): G5 > G4 > G3 > G2 > G1. G5 had the highest bond strength. In conclusion, post space pretreatments with MTAD or PIPS technique can significantly remove smear layer and improve the bond strength of glass fiber post, and combination of them works best.  相似文献   

10.
Orthodontic appliances causes specific alterations in oral environment, including reduction of pH, increase of dental biofilm and elevation of salivary microbial levels, causing an increased risk for dental caries. This study evaluated, using microbial culture and scanning electron microscopy (SEM), the in situ contamination by mutans streptococci (MS) of different surfaces of Haas palatal expanders with and without use of chlorhexidine gluconate mouthrinses (CHX). Thirty‐four patients were randomly assigned to two groups (n = 17/group), using placebo (Group I) and 0.12% CHX (Group II—Periogard®) mouthrinses twice a week. After 4 months, appliances were submitted to microbiological processing and after fragments were analyzed by SEM. Mann–Whitney U test (α = 5%) was used to assess differences between groups on the appliances' different surfaces and to compare the contamination on the free and nonfree surfaces of these components. There was no difference (p = 0.999) between groups regarding the number of MS colonies/biofilms on the nonfree surfaces, which showed intense contamination. However, free surfaces of Group II presented less contamination (p < 0.001) than those of Group I in all appliances' components. Results of the microbial culture were confirmed by SEM. Use of 0.12% CHX was effective in reducing the formation of MS colonies/biofilms on free surfaces of Haas expanders, in situ.  相似文献   

11.
Tensile properties and fracture toughness of monolithic aluminum (Al), glass fiber reinforced plastics (GFRPs) and glass fiber/aluminum hybrid laminates (GFMLs) were examined in relation to the fracture processes of plain coupon and single-edge-notched specimens. Elastic modulus and ultimate tensile strength of GFMLs showed characteristic dependences on the kind of Al, fiber orientation and the Al/fiber layer composition ratio. Fracture toughnesses KC and GC of A-GFML-UD were comparable to those of GFRP-UD and were much superior to monolithic Al. However, GFML with a transverse crack parallel to the fiber layer deteriorated largely in toughness. Microscopic observation of the fracture zone in the vicinity of the crack tip revealed various modes of micro-cracks in the respective layers as well as fiber fractures and delamination between fiber/Al layers. Such damage advances in GFMLs dependent on the orientation of the fiber layer and the Al/fiber composition ratio strongly influenced the strength and toughness of GFMLs.  相似文献   

12.
This study evaluated the effects of four over-the-counter (OTC) bleaching products on the properties of enamel. Extracted human molars were randomly assigned into four groups (n = 5): PD: Poladay (SDI), WG: White Teeth Global (White Teeth Global), CW: Crest3DWhite (Procter & Gamble), and HS: HiSmile (HiSmile). The hydrogen peroxide (H2O2) content in each product was analyzed via titration. Twenty teeth were sectioned into quarters, embedded in epoxy resin, and polished. Each quarter-tooth surface was treated with one of the four beaching times: T0: control/no-bleaching, T14: 14 days, T28: 28 days, and T56: 56 days. Materials were applied to enamel surfaces as recommended. Enamel surfaces were examined for ultramicrohardness (UMH), elastic modulus (EM), superficial roughness (Sa), and scanning electron microscopy (SEM). Ten additional teeth were used to evaluate color and degree of demineralization (DD) (n = 5). Data were statistically tested by two-way ANOVA and Tukey's tests (α = 5%). Enamel surfaces treated with PD and WG presented UMH values significantly lower than the controls (p < .05). Elastic modulus (E) was significantly reduced at T14 and T28 for PD, and at T14 for HS (p < .05). A significant increase in Sa was observed for CW at T14 (p < .05). Color changes were observed in the PD and WG groups. Additionally, DD analysis showed significant demineralization at T56 for CW. Overall, more evident morphological alterations were observed for bleaching products with higher concentrations of H2O2 (p < .05), PD, and WG. Over-the-counter bleaching products containing H2O2 can significantly alter enamel properties, especially when application time is extended.  相似文献   

13.
The aim of this double‐blind randomized study was to evaluate the biocompatibility of resin‐modified glass ionomer cements (RMGIC) by means of morphological and immunohistochemical analyses. RMGICs were selected and divided into four groups: Group CK (Crosslink Orthodontic Band Cement); Group RS (Resilience Light Cure Band Cement) Group RMO (RMO Band Cement), Group TP (Transbond Plus Light Cure Band), and Group C (Control‐polyethylene). The materials were implanted in rat subcutaneous tissues, randomly selected for this study. After time intervals of 7, 15, and 30 days the tissues were submitted to morphological analysis. In immunohistochemical analysis, the immuno‐marking of antibody CD68 was evaluated. The results obtained were statistically analyzed by the Kruskal–Wallis and Dunn tests (p < .05). In the morphological analysis after 7 days, Groups RS, RMO and TP showed more intense inflammatory infiltrate (p = .004) and only Group RMO presented greater intensity of multinucleated giant cells (p = .027). In the immunohistochemical analysis, Groups RMO and RS were observed to present a larger quantity of CD68+ (p = .004) in the time interval of 7 days and only Group RMO presented statistically significant difference for this parameter after 15 days (p = .026). In the time interval of 30 days, Group RMO presented the largest quantity of multinucleated giant cells (p < .004). The RMGICS Crosslink and Transbond Plus provided significantly better tissue biocompatibility than the Resilience and RMO Cements.  相似文献   

14.
The aim of this study was to compare the cyclic fatigue resistance of rotary NiTi files, produced with four different manufacturing methods on specially designed dynamic models that simulated clinical conditions. In this study, 120 files, consisting of 30 files for Typhoon, ProTaper Next, RaCe, and Twisted Files nickel titanium rotary systems were used. The 30 files of each group were divided into three subgroups to be used in artificial canals with a 60° angle of curvature and radii of curvature of 2, 5, and 8 mm (n = 10). All files were rotated in the artificial canals until fracture occurred and the number of cycles to fracture was calculated. The data were analyzed using one‐ and two‐way analyses of variance and Tamhane multiple comparison tests. In all three groups, Typhoon instruments had the highest number of cycles to failure than the RaCe, ProTaper Next, and Twisted Files instruments, and the difference statistically significant (p < .05). There were no significant differences between the RaCe, ProTaper Next, and Twisted Files groups (p > .05). The CM wire Typhoon system was significantly more resistant to cyclic fatigue compared to the other file systems in all three artificial canals. When the fracture resistance of an instrument in three different artificial canals was compared, the mean NCFs decreased as the radius of the curvature of the canal decreased from 8 to 2 mm. Manufacturing method is one of the most important factors on cyclic fatigue resistance, also the radius of curvature effects the cyclic fatigue.  相似文献   

15.
The purpose of this study was to examine the effect of different cleaning methods and resin cements on the shear bond strength (SBS) of contaminated zirconia. A total of 92 disc-shaped zirconia specimens were contaminated with different procedures. Then, the specimens were grouped according to cleaning methods and resin cements: no cleaning + Variolink Esthetic DC (CNV), no cleaning + Panavia V5 (CNP), sandblasted + Variolink Esthetic DC (SBV), sandblasted + Panavia V5 (SBP), Ivoclean + Variolink Esthetic DC (ICV), Ivoclean + Panavia V5 (ICP), Katana Cleaner + Variolink Esthetic DC (KCV), and Katana Cleaner + Panavia V5 (KCP). Following an aging protocol in a 37°C for 1 week, SBS analysis was performed with a universal test machine. For the surface topography and elemental analysis, scanning electron microscopy and energy-dispersive X-ray spectroscopy (EDS) were used. Significance was evaluated as p < .05 and p < .01. The highest SBS results were found in the SBP group, showing a statistically significant difference from all other groups (p < .05). For the same cleaning method, Panavia V5 showed statistically significantly higher SBS values than Variolink Esthetic DC (p < .01), except the CNP–CNV (p = .880) and KCP–KCV (p = .082) groups. The most detected surface elements by EDS were Zr, O, C, and N, respectively. The contaminated zirconia surfaces must be cleaned for successful adhesion. The use of phosphate-containing adhesives in combination with sandblasting will increase the adhesion strength, and universal cleaning agents can be a good alternative to sandblasting.  相似文献   

16.
Continuous fiber ceramic composites (CFCCs) have advantages over monolithic ceramics: Silicon Nitride composites are not well used for application because of their low fracture toughness and fracture strength, but CFCCs exhibit increased toughness for damage tolerance, and relatively high stiffness in spite of low specific weight. Thus it is important to characterize the fracture resistance and properties of new CFCCs materials. Tensile and flexural tests were carried out for mechanical properties and the fracture resistance behavior of a SCS6 fiber reinforced Si3N4 matrix CFCC was evaluated. The results indicated that CFCC composite exhibit a rising R curve behavior in flexural test. The fracture toughness was about 4.8 MPa m1/2 , which resulted in a higher value of the fracture toughness because of fiber bridging. Mechanical properties as like the elastic modulus, proportional limit and the ultimate strength in a flexural test are greater than those in a tensile test. Also a numerical modeling of failure process was accomplished for a flexural test. This numerical results provided a good simulation of the cumulative fracture process of the fiber and matrix in CFCCs.  相似文献   

17.
This study evaluated the effect of 10% sodium hypochlorite (NaOCl) as deproteinizing agent and storage media on bond strength (BS) of two etch‐and‐rinse adhesive systems to dentin. Twenty‐eight sound extracted human third molars were divided in four groups (n = 7), according to dentin treatment (conventional etching or etching followed by 10% NaOCl application) and adhesive systems (GB—Gluma 2Bond and OS—One‐Step). After dentin treatments and adhesive application, a composite block was built‐up on dentin surface and teeth were serially sectioned to obtain bonded sticks specimens. The sticks were submitted to three aging conditions: (24H) 24 hr in water (immediate), (SH) 3 hr of NaOCl accelerated‐aging or (1Y) 1 year of water storage. Afterward, submitted to microtensile bond strength test (μTBS), failure modes and adhesive interfaces analyzes. Data were analyzed by two‐way analysis of variance (ANOVA) and Tukey's test (α = .05). Dentin deproteinization before bonding significantly reduced μTBS for GB‐treated group (p < .05), regardless the aging conditions. Water storage for 1 year (1Y) and NaOCl accelerated‐aging (SH) decreased μTBS for both adhesives. Yet, the groups stored in NaOCl (SH) exhibited the lowest BS results (p < .05). Bond strength of deproteinized dentin was dependent on the adhesive system composition and NaOCl accelerated‐aging promoted decreased bond strength and further degradation than water storage for 1 year.  相似文献   

18.
Chronic kidney disease (CKD) is a relevant disease in feline clinic. The tubulointerstitial damage, with collagen deposition and fibrosis, is an important result of this process. The aim of this study was to quantify and correlate the deposition of collagen and severity of interstitial fibrosis (IF) in the kidney from cats in different stages of CKD. Kidney fragments from 10 adult cats with CKD were analyzed and stained by Masson's trichrome (MT) and Picrosirius red (PSR) for circular polarized microscopy. Random quantitative analysis was performed on MT sections to classify the degree of IF, per field area, with and without circular polarization. Statistics correlations were performed by Spearman's (ρ; p < .05). There was a significant correlation of IF quantification with the area of interstitial collagen deposition by polarized PSR (PSRp) (r = .7939, p = .0098) and nonpolarized PSR (PSRn) (r = .7781, p = .0080). There was a positive correlation of serum creatinine (sCr) at different stages of CKD with PSRp (r = .7939, p = .0098), PSRn (r = .8667, p = .0027) and MT (r = .7818, p = .0117). Correlations between the percentage of quantified area was also positive from PSRp to PSRn (r = .9030, p = .0009) and PSRp to MT (r = .7939, p = .0098). The PSRN was also correlated with MT (r = .9273, p = .0001). The correlation with IF and sCr follows the disease evolution and the quantification of collagen by PSR is an excellent tool for analyzing the disease severity at different stages.  相似文献   

19.
The purpose of this study was to evaluate the efficiency of the Er:YAG laser and diamond bur cavity preparation on the marginal microleakage of Class V cavities. Group 1: bur preparation (bp) + Vertise Flow (VF); Group 2: laser preparation (lp) + VF; Group 3: bp + Adper Easy One (AEO) + Filtek Ultimate Flowable Composite (FUFC); Group 4: lp + AEO + FUFC; Group 5: bp + Clearfil S3 Bond (CSB) + Clearfil Majesty Flow (CMF); Group 6: lp + CSB + CMF. Data were analyzed by Kruskal–Wallis and Mann–Whitney U tests (p < .05). More microleakage was observed in cervical regions compared to occlusal regions in all groups (p < .05). No significant difference was observed among all groups in terms of occlusal and cervical surfaces, respectively (p > .05). The use of the Er:YAG laser for cavity preparation with different adhesive systems and flowable composites did not influence microleakage.  相似文献   

20.
An apparatus is described which allows freeze-fracturing at defined temperatures, followed by immediate immersion of the specimen in liquid nitrogen. Replication is carried out in a Bullivant & Ames (1966) freeze-fracture device. Using yeast as a test specimen, the following results were obtained with the apparatus: (a) It was confirmed that fracturing at temperatures between 243 K and 223 K gave undeformed volcanoes on the PF of the plasma membrane, as shown originally by Steere et al. (1980). (b) Considerable energy is released by the fracturing process, both as shown by thermocouple readings and by the fact that at relatively high fracture temperatures portions of the specimen surface were melted. A temperature rise of 50–70 K was indicated, (c) Under standard conditions, there is a lack of complementarity between the yeast plasma membrane fracture faces, trigonal point particles not being present opposite the corresponding depressions in the array. Fracturing yeast suspended in salt solutions at 203 K demonstrates these particles. Their absence in normal fractures can be explained by ‘secondary fracture’, a concept based on polymer fracture studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号