To provide a basis for the selection of suitable emulsifiers in oil-in-water emulsions used as tissue analogs for MRI experiments. Three different emulsifiers were investigated with regard to their ability to stabilize tissue-like oil-in-water emulsions. Furthermore, MR signal properties of the emulsifiers themselves and influences on relaxation times and ADC values of the aqueous phase were investigated.
Materials and methods
Polysorbate 60, sodium dodecyl sulfate (SDS) and soy lecithin were used as emulsifiers. MR characteristics of emulsifiers were assessed in aqueous solutions and their function as a stabilizer was examined in oil-in-water emulsions of varying fat content (10, 20, 30, 40, 50%). Stability and homogeneity of the oil-in-water emulsions were evaluated with a delay of 3 h and 9 h after preparation using T1 mapping and visual control. Signal properties of the emulsifiers were investigated by 1H-MRS in aqueous emulsifier solutions. Relaxometry and diffusion weighted MRI (DWI) were performed to investigate the effect of various emulsifier concentrations on relaxation times (T1 and T2) and ADC values of aqueous solutions.
Results
Emulsions stabilized by polysorbate 60 or soy lecithin were stable and homogeneous across all tested fat fractions. In contrast, emulsions with SDS showed a significantly lower stability and homogeneity. Recorded T1 maps revealed marked creaming of oil droplets in almost all of the emulsions with SDS. The spectral analysis showed several additional signals for polysorbate and SDS. However, lecithin remained invisible in 1H-MRS. Relaxometry and DWI revealed different influences of the emulsifiers on water: Polysorbate and SDS showed only minor effects on relaxation times and ADC values of aqueous solutions, whereas lecithin showed a strong decrease in both relaxation times (r1,lecithin = 0.11 wt.%−1 s−1, r2,lecithin = 0.57 wt.%−1 s−1) and ADC value (Δ(ADC)lecithin = − 0.18 × 10–3 mm2/s⋅wt.%) with increasing concentration.
Conclusion
Lecithin is suggested as the preferred emulsifier of oil-in-water emulsions in MRI as it shows a high stabilizing ability and remains invisible in MRI experiments. In addition, lecithin is suitable as an alternative means of adjusting relaxation times and ADC values of water.
The efficient substitution of sucrose by a sweetener in beverages requires the application of some sensory techniques. First, one must determine the concentrations of the sweeteners under study, equivalent in sweetness to the ideal sucrose concentration. In addition, it is fundamental to determine which is most similar to sucrose. The objectives of this study were to determine the ideal sweetness for espresso coffee and the equivalent concentrations in sweetness of different sweeteners, as well as characterise the time–intensity profile of each sweetener in relation to sweetness. The sweeteners evaluated were sucralose, aspartame, neotame, a cyclamate/saccharin mixture (2:1) and stevia. The sucrose concentration considered ideal by consumers was 12.5% (w/v), and the equivalent concentrations of the sweeteners were 0.0159% for sucralose, 0.0549% for aspartame, 0.0016% for neotame, 0.0359% for the cyclamate/saccharin mixture and 0.0998% for stevia. The time–intensity analysis indicated that possibly the sweeteners neotame, aspartame and sucralose would be the best substitutes for sucrose. 相似文献
Protozoal infections are still a global health problem, threatening the lives of millions of people around the world, mainly in impoverished tropical and sub-tropical regions. Thus, in view of the lack of efficient therapies and increasing resistances against existing drugs, this study describes the antiprotozoal potential of synthetic cinnamate ester analogues and their structure-activity relationships. In general, Leishmania donovani and Trypanosoma brucei were quite susceptible to the compounds in a structure-dependent manner. Detailed analysis revealed a key role of the substitution pattern on the aromatic ring and a marked effect of the side chain on the activity against these two parasites. The high antileishmanial potency and remarkable selectivity of the nitro-aromatic derivatives suggested them as promising candidates for further studies. On the other hand, the high in vitro potency of catechol-type compounds against T. brucei could not be extrapolated to an in vivo mouse model. 相似文献
The hydrogen content, its depth distribution, and its bonding configuration have been studied in hydrogenated amorphous silicon prepared by plasma-enhanced chemical vapor deposition with hydrogen-diluted silane. Nuclear reaction analysis and infrared spectroscopy were used to determine the total amount of hydrogen and its bonded component, respectively. It has been established that the total concentration of hydrogen does not depend on the film thickness, and has a uniform depth profile. The concentration of bonded hydrogen changes with the film thickness within the measurement accuracy. The data obtained suggest the presence of molecular (non-bonded) hydrogen, uniformly distributed in concentration across the film thickness. 相似文献
OBJECTIVE: To compare a system that continuously monitors cardiac output by the Fick principle with measurements by the thermodilution technique in pediatric patients. DESIGN: Prospective direct comparison of the above two techniques. SETTING: Pediatric intensive care unit of a university hospital. PATIENTS: 25 infants and children, aged 1 week to 17 years (median 10 months), who had undergone open heart surgery were studied. Only patients without an endotracheal tube leak and without a residual shunt were included. METHODS: The system based on the Fick principle uses measurements of oxygen consumption taken by a metabolic monitor and of arterial and mixed venous oxygen saturation taken by pulse- and fiberoptic oximetry to calculate cardiac output every 20s. INTERVENTIONS: In every patient one pair of measurements was taken. Continuous Fick and thermodilution cardiac output measurements were performed simultaneously, with the examiners remaining ignorant of the results of the other method. RESULTS: Cardiac output measurements ranged from 0.21 to 4.55 l/min. A good correlation coefficient was found: r2 = 0.98; P < 0.001; SEE = 0.41 l/min. The bias is absolute values and in percent of average cardiac output was - 0.05 l/min or - 4.4% with a precision of 0.32 l/min or 21.3% at 2 SD, respectively. The difference was most marked in a neonate with low cardiac output. CONCLUSION: Continuous measurement of cardiac output by the Fick principle offers a convenient method for the hemodynamic monitoring of unstable infants and children. 相似文献