首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   63篇
  免费   6篇
化学工业   7篇
金属工艺   3篇
建筑科学   3篇
能源动力   3篇
无线电   7篇
一般工业技术   29篇
冶金工业   4篇
原子能技术   1篇
自动化技术   12篇
  2023年   4篇
  2022年   7篇
  2021年   3篇
  2020年   3篇
  2019年   6篇
  2018年   6篇
  2017年   6篇
  2016年   5篇
  2014年   4篇
  2013年   1篇
  2012年   4篇
  2011年   4篇
  2010年   10篇
  2009年   2篇
  2008年   1篇
  2006年   1篇
  1998年   1篇
  1997年   1篇
排序方式: 共有69条查询结果,搜索用时 31 毫秒
1.
2.
Early diagnosis remains highly important for efficient cancer treatment,and hence,there is significant interest in the development of effective imaging strategies.This work reports a new multimodal bioimaging method for accurate and rapid diagnosis of cancer cells by introducing aqueous Fe2+ and Zn2+ ions into cancer cells (i.e.,HeLa,U87,and HepG2 cancer cells).We found that the biocompatible metal ions Fe2+ and Zn2+ forced the cancer cells to spontaneously synthesize fluorescent ZnO nanoclusters and magnetic Fe3O4 nanoclusters.These clusters could then be used for multimodal cancer imaging by combining fluorescence imaging with magnetic resonance imaging and computed tomography imaging.Meanwhile,for normal cells (i.e.,L02) and tissues,neither fluorescence nor any other obvious difference could be detected between preand post-injection.This multimodal bioimaging strategy based on the in situ biosynthesized Zn&Fe oxide nanoclusters might therefore be useful for early cancer diagnosis and therapy.  相似文献   
3.
Link relative-based approach was used in an article (see reference 1) to enhance the performance of the cumulative sum (CUSUM) control chart. This technique involves the use of firstly, the link relative variable to convert the process observations in a relative to the mean form and secondly, optimal constants to define a new variable which is used as the plotting statistic of the link relative CUSUM chart. In this article, it is proven through simulation study that the optimal constants with fixed values, as reported in the aforementioned article, give different results. Instead, if the regression technique is used, then the same results will be obtained.  相似文献   
4.
Neural Computing and Applications - Content protection is considered as an important issue in today’s world. Therefore, encryption of such contents is a challenging task for researchers. They...  相似文献   
5.
For precise and accurate patient dose delivery,the dosimetry system must be calibrated properly according to the recommendations of standard dosimetry protocols such as TG-51 and TRS-398. However, the dosimetry protocol followed by a calibration laboratory is usually different from the protocols that are followed by different clinics, which may result in variations in the patient dose.Our prime objective in this study was to investigate the effect of the two protocols on dosimetry measurements.Dose measurements were performed for a Co-60 teletherapy unit and a high-energy Varian linear accelerator with 6 and 15 MV photon and 6, 9, 12, and 15 MeV electron beams, following the recommendations and procedures of the AAPM TG-51 and IAEA TRS-398 dosimetry protocols. The dosimetry systems used for this study were calibrated in a Co-60 radiation beam at the Secondary Standard Dosimetry Laboratory(SSDL) PINSTECH,Pakistan, following the IAEA TRS-398 protocol. The ratio of the measured absorbed doses to water in clinical setting,D_w(TG-51/TRS-398), was 0.999 and 0.997 for 6 and15 MV photon beams,whereas these ratios were 1.013,1.009, 1.003, and 1.000 for 6, 9, 12, and 15 MeV electron beams, respectively. This difference in the absorbed dosesto-water D_w ratio may be attributed mainly due to beam quality(K_Q) and ion recombination correction factor.  相似文献   
6.

Due to limited depth-of-field of digital single-lens reflex cameras, the scene content within a limited distance from the imaging plane remains in focus while other objects closer to or further away from the point of focus appear as blurred (out-of-focus) in the image. Multi-Focus Image Fusion can be used to reconstruct a fully focused image from two or more partially focused images of the same scene. In this paper, a new Fuzzy Based Hybrid Focus Measure (FBHFM) for multi-focus image fusion has been proposed. Optimal block size is very critical step for multi-focus image fusion. Particle Swarm Optimization (PSO) algorithm has been used to find optimal size of the block of the images for extraction of focus measure features. After finding optimal blocks, three focus measures Sum of Modified Laplacian, Gray Level Variance and Contrast Visibility has been extracted and combined these focus measures by using intelligent fuzzy technique. Fuzzy based hybrid intelligent focus values were estimated using contrast visibility measure to generate focused image. Different sets of multi-focus images have been used in detailed experimentation and compared the results with state-of-the-art existing techniques such as Genetic Algorithm (GA), Principal Component Analysis (PCA), Laplacian Pyramid discrete wavelet transform (DWT), and aDWT for image fusion. It has been found that proposed method performs well as compare to existing methods.

  相似文献   
7.
The progressive mean (PM) statistic is based on a simple idea of accumulating information of each subgroup by calculating the average progressively. Its weighting structure is based on a subgroup number that changes arithmetically, which makes the PM chart unique and efficient compared with the existing classical memory control charts. In a recent article (see reference 1), it was claimed that the PM chart is a special case of the exponentially weighted moving average (EMWA) chart. In this article, it is shown that even though the PM statistic can be written in the form of an EWMA statistic, the variance of the PM statistic is different from that of the EWMA statistic. Consequently, the limits of the PM chart are different from that of the EWMA chart. Therefore, it is found that the PM chart is not a special case of the EWMA chart; hence, the claim in reference 1 is incorrect. Furthermore, it is pointed out in this paper that no adaptive property in the weighting parameter of the PM statistic exists, further contradicting the claim in reference 1.  相似文献   
8.
This paper presents the results of novel one-step quenching and partitioning (Q&P) heat treatment conducted on medium carbon low alloy steel sheet. Samples were austenitised at 1193 K followed by interrupted quenching at 473 K for different partitioning times and finally they were quenched in water. Dilatometry was employed for selection of treatment temperatures. Optical and scanning electron microscopy was carried out to examine the microstructural changes. Volume fraction of retained austenite was measured by x-ray diffraction technique. Resulting microstructures were correlated with the mechanical properties such hardness, tensile strength, elongation, impact absorbed energy, etc. The notch tensile and fracture toughness properties of Q&P steels are still lacking therefore notch tensile strength and plain strain fracture toughness tests were conducted and results are reported here. Results of Q&P treatments were also compared with the properties obtained by conventional Quenching and Tempering (Q&T) and normalizing treatments. Optimum strength-ductility balance of about 2000 MPa tensile strength with 11% elongation was achieved in samples quenched at 473 K and isothermally partitioned for 100 s. Higher ductility of Q&P steel was attributed to the presence of 6.8% film-type interlath retained austenite. Fine-grained martensitic structure with high density of interphase boundaries imparted ultrahigh strength. It was further noted that the impact toughness, notch tensile strength and fracture toughness of 1000 s partitioned samples was higher than 100 s partitioned samples. Possible reasons for high toughness are synergetic effect of recovery of dislocations, partial loss of martensite tetragonality and precipitation of fine transition carbides.  相似文献   
9.
Cancer treatment has a far greater chance of success if the neoplasm is diagnosed before the onset of metastasis to vital organs. Hence, cancer early diagnosis is extremely important and remains a major challenge in modern therapeutics. In this contribution, facile and new method for rapid multimodal tumor bioimaging is reported by using biosynthesized iron complexes and gold nanoclusters via simple introduction of AuCl4 ? and Fe2+ ions. The observations demonstrate that the biosynthesized Au nanoclusters may act as fluorescent and computed tomography probes for cancer bioimaging while the iron complexes behave as effective contrast agent for magnetic resonance imaging. The biosynthesized iron complexes and gold nanoclusters are found biocompatible in vitro (MTT (3‐(4, 5‐dimethylthiazol‐2‐yl)‐2, 5‐diphenyltetrazolium bromide) assay) and in vivo for all the vital organs of circulatory and excretory system. These observations raise the possibility that the biosynthesized probes may find applications in future clinical diagnosis for deep seated early neoplasms by multimodal imaging.  相似文献   
10.
Melting temperatures of zirconium carbide were investigated in validating a novel thermal analysis technique for refractory materials. Commercial ZrC0.96 powder was densified by spark plasma sintering to >96% relative density after 6–30 min at 2173–2453 K under 40–100 MPa. Sintered ceramics were heated to >4000 K via pulsed laser heating. Mean values for solidus and liquidus transitions were 3451 and 3608 K, respectively, in fair agreement with the present phase diagram. Postmelting analysis revealed dendritic microstructure and composition consistent with single-phase ZrC. Subsurface gas porosity and ZrC–C eutectic indicate complex processes occurring during melting and freezing.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号