排序方式: 共有95条查询结果,搜索用时 15 毫秒
2.
弹性电网及其恢复力的基本概念与研究展望 总被引:3,自引:0,他引:3
恢复力是系统对扰动事件抵御、适应以及快速恢复的能力。随着全球自然灾害逐渐增多以及反恐意识的增强,构建对极端扰动事件具有恢复力的"弹性电网"已成为各国政府着力发展的国家战略,同时智能电网的快速发展也为弹性电网的研究提供了新的机遇。文中详细介绍了弹性电网及其恢复力的基本概念与各国的研究现状,并从弹性电网需要应对的扰动事件、评估理论、恢复力提升策略等方面入手,详细分析弹性电网及其恢复力研究方向和重点,以及在智能电网框架下构建弹性电网的具体措施。最后对弹性电网研究进行了展望,提出了进一步深入研究的方向。 相似文献
4.
5.
6.
Modeling Methods for the Main Switch of High Pulsed-Power Facilities Based on Transmission Line Code
Based on the transmission line code (TLCODE), a circuit model is developed here for analyses of main switches in the high pulsed-power facilities. With the structure of the ZR main switch as an example, a circuit model topology of the switch is proposed, and in particular, calculation methods of the dynamic inductance and resistance of the switching arc are described. Moreover, a set of closed equations used for calculations of various node voltages are theoretically derived and numericMly discretized. Based on these discrete equations and the Matlab program, a simulation procedure is established for analyses of the ZR main switch. Voltages and currents at different key points are obtained, and comparisons are made with those of a PSpice L-C model. The comparison results show that these two models are perfectly in accord with each other with discrepancy less than 0.1%, which verifies the effectiveness of the TLCODE model to a certain extent. 相似文献
7.
Pseudo-spark switch(PSS) is one of the most widely used discharge switches for pulse power technology.It has many special characteristics such as reliability in a wide voltage range,small delay time,as well as small delay jitter.In this paper,the measuring method for the initial plasma of ZnO surface flashover triggering device of PSS is studied and the results of the measurement show that the electron emission charge is mainly influenced by trigger voltage,gas pressure and DC bias voltage.When the bias voltage increases from 2 kV to 6 kV with the gap distancc fixed at 3 mm,the electron emission charge changes from 2 μC to about 6μC.When the gap distance changes from 3 mm to 5 mm with the bias voltage fixed at 2 kV,the electron emission charge increases from 1.5 μC to 2.5μC.When the gap distance is 4 mm,the hold-off voltage of PSS is 45 kV at gas pressure of 2 Pa,the minimum operating voltage is less than 1 kV.So,the operating scope is from 2.22%to 99%of its self-breakdown voltage.The discharging delay time decreases from 450 ns to 150 ns when the trigger pulse voltage is 1 kV and the discharging voltage is changed from 1 kV to 12 kV.When the trigger pulse voltage is 6 kV,the discharging delay time is less than 100 ns and changes from 100 ns to 50 ns,and the delay jitters are less than30 ns. 相似文献
8.
Criterion of Magnetic Saturation and Simulation of Nonlinear Magnetization for a Linear Multi-core Pulse Transformer 总被引:1,自引:0,他引:1
The linear multi-core pulse transformer is an important primary driving source used in pulsed power apparatus for the production of dense plasma owing to its compact,relatively low-cost and easy-to-handle characteristics.The evaluation of the magnetic saturation of the transformer cores is essential to the transformer design,because the energy transfer efficiency of the transformer will degrade significantly after magnetic saturation.This work propses analytical formulas of the criterion of magnetic saturation for the cores when the transformer driver practical loads.Furthermore,an electric circuit model based on a dependent source treatment for simulating the electric behavior of the cores related to their nonlinear magnetization is developed using the initial magnetization curve of the cores.The numerical simulation with the model is used to evaluate the validity of the criterion.Both the criterion and the model are found to be in agreement with the experimental data. 相似文献
9.
10.