首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   34篇
  免费   2篇
电工技术   1篇
化学工业   8篇
建筑科学   1篇
能源动力   4篇
轻工业   6篇
无线电   4篇
一般工业技术   5篇
冶金工业   2篇
自动化技术   5篇
  2022年   1篇
  2021年   1篇
  2020年   1篇
  2019年   1篇
  2018年   2篇
  2016年   1篇
  2015年   1篇
  2014年   2篇
  2013年   5篇
  2012年   3篇
  2011年   2篇
  2010年   2篇
  2009年   2篇
  2008年   2篇
  2007年   2篇
  2006年   1篇
  2005年   2篇
  2004年   1篇
  1995年   1篇
  1992年   1篇
  1991年   1篇
  1980年   1篇
排序方式: 共有36条查询结果,搜索用时 31 毫秒
1.
Overhead line energization can be performed under normal or faulty conditions. The latter indicates an occurrence of a fault along the line that exists at the moment of energization. This can lead to significant over-voltages that could endanger proper line operation. The issue gets more complex to protective devices when it comes to high-resistance faults, which impair the ability of relays to react promptly and accurately. Consequently, installation of additional detection devices becomes necessary. This paper proposes a novel method that properly detects and classifies line operating conditions at the moment of energization. The method is designed to be useful for utilities and it can be considered as a low-cost, fast, and accurate detection and classification approach, suitable for dealing with both low-resistance and high-resistance faults. Through comprehensive mathematical modeling it was found that both normal and faulty conditions during line energization are accompanied by the zero-sequence voltages of specific characteristics. The differences between zero voltage sequences are reflected in harmonic content, magnitudes of dominant frequencies, and their phase angles in regard to supply voltage. These findings are taken as the method's detection and classification criteria. The validity of the proposed model is verified by simulations and by field measurements.  相似文献   
2.
3.
4.
Hydrogen is considered to be the most promising candidate as a future energy carrier. One of the most used technologies for the electrolytic hydrogen production is alkaline water electrolysis. However, due to high energy requirements of about 4.5-5 kWh/Nm3 H2 in most industrial electrolysers, the cost of hydrogen produced in such a way is high. There are various attempts to overcome this problem, like zero-gap cell geometry, development of new diaphragm materials, development of new electrocatalytic materials for electrodes, etc.In continuous search to improve this process using advanced electrocatalytic materials for the hydrogen evolution reaction (HER), based on transition metal series, catalyst based of cobalt and wolfram was investigated as cathode material. On the basis of the results of our experiments, there is a strong indication that the Co-W catalyst reduces energy needs per mass unit of hydrogen produced for more than 20% in some cases. Objective of this work was to investigate the electrocatalytic efficiency using quasi-potentiostatic, galvanostatic and impedance spectroscopy techniques. Results are presented to show the Tafel slopes, the exchange current densities, the apparent energy of activation, the apparent electrochemical surface and the stability of Co-W catalyst. Results suggest to significant catalytic performance not only from the increase of the real surface area of electrodes, but also from the true catalytic effect of the Co-W catalyst.  相似文献   
5.
The aim of the study described in this paper is to determine the character of deposits formed on the inner wall of an submerge entry nozzle during the continuous casting of steel. By using X‐ray diffraction and optic microscopy with refracted light, it has been found that the minerals most abundant in the deposit's structure are corundum, hibonite‐5H, hematite, graphite and, in certain cases, there is also magnetite. The results of the examination of the mineralogical composition and of the structure of the SEN wall after the exploitation in the continuous steel casting process are also shown.  相似文献   
6.
Selection of hand tools for cost-effective assembly and maintenance of a mechanical system has a significant impact on its life-cycle cost. A knowledge-based automated procedure for the selection of hand tools needed to efficiently carry out fastening operations in a mechanical assembly is presented. The objective is to select a tool that is applicable to a particular fastening operation, minimizes time and cost of the fastening operation, and satisfies accessibility requirements, and to provide design assistance to the design engineer. The role of the tool selection procedure in the concurrent design of mechanical systems is described.  相似文献   
7.
This study deals with total phenolic content, antiproliferative and proapoptotic activity of methanolic extracts from different Teucrium species and the effect on the prooxidant/antioxidant status in HCT-116 cells. The total phenolic content of the extracts was measured spectrophotometricaly and the obtained results ranged from 56.62 mg/g to 172.50 mg GA/g. The antiproliferative activity of methanolic extracts from different Teucrium species was determined using MTT cell viability assay, where IC(50) value was used as a parameter for cytotoxicity. The type of cell death was explored by fluorescence microscopy using the acridin orange/ethidium bromide method. MTT assay showed that all extracts significantly reduced cell viability in a dose-dependent manner, with very low IC(50) values. The highest content of phenolic compounds and the best cytotoxic activity on HCT-116 cells after 24 h of exposure was in T. chamaedrys extract, with IC(50) values of 5.48 × 10(-9) μg/mL. After 72 h, methanolic extract of T. arduini appeared to have the best cytotoxic activity on HCT-116, with IC(50) values of 0.37 μg/mL. Treatments caused typical apoptotic morphological changes in HCT-116 cells and showed a high percentage of apoptotic cells. The results of the presented research indicate that some Teucrium extracts are a very rich source of phenols, which may directly contribute to high antiproliferative and proapoptotic activity.  相似文献   
8.
Oily water treatment using a new steady-state fiber-bed coalescer   总被引:1,自引:0,他引:1  
This study was concerned with the possibility of oil separation from two heavily polluted wastewater types: formation water and wastewater from hardening shop, using bed a newly developed coalescer. Experiments were carried out using original wastewaters and an artificial model wastewater. Results obtained for seven samples of formation water of very different quality showed that the water properties had no significant effect on bed coalescence efficiency. In contrast to this, crude oil properties strongly influenced steady-state bed coalescence. In the treatment of hardening oily wastewater in situ during a 4-month period oil concentration in the effluent was less than 20mg/l in all experiments. It appeared that oil concentration and water quality had no effect on bed separation efficiency. Special design of the coalescer and use of two filter materials ensured its good performance. Namely, the pipe-in-pipe construction provided the water orientation change several times while passing through the unit, making inertia one of dominant separation mechanisms.  相似文献   
9.
The activity concentrations and distribution of natural and anthropogenic radionuclides in soils from the city of Kavadarci, Republic of Macedonia, and its environs were investigated. The purpose of the study, the first of this kind in this region was to evaluate the environmental radioactivity and radiological health hazard, as well as to determine the connection between the concentration of natural radionuclides and the geology of the terrain. A total of 45 surface soil samples were collected from evenly distributed sampling sites. Gross alpha and gross beta activity measurements were made using a gas flow proportional counter, while the activity concentrations of gamma emitting radionuclides were measured using a high purity germanium detector. The average activity concentrations of ??K, 22?Ra, 232Th and 13?Cs were found to be 546±118, 38.8±14.6, 43.7±18.4 and 41.5±40 Bq kg?1, respectively. The mean values of gross alpha and gross beta activities were 522±192 and 681±146 Bq kg?1. The mean total absorbed dose rate in air calculated from the concentration of the natural radionuclides was 67.1±20.9 nGy h?1, and the corresponding annual effective dose rate outdoors was 0.082±0.026 mSv y?1. The results of the analysis show strong correlation between the abundance of the natural radionuclides in soils and their geological origin.  相似文献   
10.
Chronopotentiometric stripping analysis (CSA) was used for selective determination of As(III) and As(V) in different oilseeds. After the optimization of experimental parameters an appropriate procedure for sample pretreatment was developed. A detection limit of 2 microg/dm3 for As(III) was obtained with an electrolysis time of 600 s. This method was used for arsenic determination in sunflower, pumpkin, and flax seed, as well as for soy flakes and almond.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号