1.
Typically, 15–45% of the mixed liquor (sludge) in biological wastewater treatment plants (WWTPs) consists of inorganic (fixed) suspended solids. A portion of these inorganic compounds is grit (sand) originating from the influent. Grit accumulation impacts WWTP design and operating costs as these unbiodegradable solids reduce the effective treatment capacity of the bioreactor and other unit operations that must be sized to carry this material.The goal of this study was to characterize the performance of a hydrocyclone to selectively separate grit from activated sludge. Laboratory experiments were conducted with a 13 mm diameter Krebs hydrocyclone treating sludge from eight WWTPs. Reduced efficiencies of 17 ± 7% on fixed suspended solids and 9 ± 6% on volatile suspended solids were obtained. Grade efficiency curves enabled the development of a modified definition for cut size useful for this application. The characterization of hydrocyclone performance for grit removal from activated sludge will enable modelling of the process for integration into wastewater treatment simulators used for process performance prediction and design.  相似文献   