首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   7篇
  免费   0篇
化学工业   1篇
机械仪表   1篇
建筑科学   1篇
能源动力   3篇
一般工业技术   1篇
  2019年   1篇
  2013年   3篇
  2010年   2篇
  1977年   1篇
排序方式: 共有7条查询结果,搜索用时 671 毫秒
1
1.
This paper presents characteristics of turbulent convective heat transfer in a tube fitted with wire coil turbulators. Two different wire coils are introduced: (1) with typical/uniform coil pitch ratio (CR) and (2) with periodically varying three-coil pitch ratio. Various uniform coil pitch ratios (CR = 4, 6, and 8) and two periodically varying coil pitch ratios, the D-coil (decreasing three-coil pitch ratio arrangement) and DI-coil (decreasing/increasing three-coil pitch ratio arrangement), are experimentally investigated in a uniform heat flux tube. The experiments are performed for turbulent flows with Reynolds numbers ranging between 4500 and 20,000. All of the experimental results are compared with those obtained from using the plain tube, while the thermal performance factor is evaluated under an equal pumping power constraint. The experimental results show that the use of the tube fitted with all wire coils leads to an advantage on the basis of heat transfer enhancement over the plain tube with no insert. It is also observed that the uniform-pitch wire coil with higher coil pitch ratio (CR = 8) gives a higher thermal performance factor compared to ones with lower coil pitch ratios (CR = 4 and 6). In addition, for two periodically varying coil pitch ratios, the DI-coil performs with better heat transfer rate than the uniform-pitch ratio (CR = 6) and the D-coil for all Reynolds number ranges studied. The empirical correlations developed in terms of coil pitch ratios (CR), varying coil pitch ratios (D-coil and DI-coil), and Reynolds number are fitting the experimental data within plus or minus 3% and 5% for Nusselt number (Nu) and friction factor (f), respectively. The results of the thermal performance factor for various CR, D-coil, and DI-coil values are also determined.  相似文献   
2.
Perforated conical-ring (PCR) is one of the turbulence-promoter/turbulator devices for enhancing the heat transfer rate in a heat exchanger system. In the present paper, the influences of the PCR on the turbulent convective heat transfer (Nu), friction factor (f) and thermal performance factor (η) characteristics have been investigated experimentally. The perforated conical-rings (PCRs) used are of three different pitch ratios (PR = p/D = 4, 6 and 12) and three different numbers of perforated holes (N = 4, 6 and 8 holes). The experiment conducted in the range of Reynolds number between 4000 and 20,000, under uniform wall heat flux condition and using air as the testing fluid. The experimental results obtained by using the plain tube and the tube equipped with the typical conical-ring (CR) are also reported for comparison. It is found that the PCR considerably diminishes the development of thermal boundary layer, leading to the heat transfer rate up to about 137% over that in the plain tube. Evidently, the PCRs can enhance heat transfer more efficient than the typical CR on the basis of thermal performance factor of around 0.92 at the same pumping power. Over the range investigated, the maximum thermal performance factor of around 0.92 is found at PR = 4 and N = 8 holes with Reynolds number of 4000.  相似文献   
3.
4.
The influences of circular-ring turbulators (CRT) and twisted tape (TT) swirl generators on the heat transfer enhancement, pressure drop and thermal performance factor characteristics in a round tube are reported. The circular-ring turbulators were individually employed and together with the twisted tape swirl generators in the heated section of the tube. Three different pitch ratios (l/D1.0, 1.5, and 2.0) of the CRT and three different twist ratios (y/W 3, 4, and 5) of the TT were introduced. The experiments were conducted using air as the working fluid under a uniform wall heat flux condition, for the Reynolds number between 6000 and 20000. The experimental results reveal that the heat transfer rate, friction factor and thermal performance factor of the combined CRT and TT are considerably higher than those of CRT alone. For the range examined, the increases of mean Nusselt number, friction factor and thermal performance, in the tube equipped with combined devices, respectively, are 25.8%, 82.8% and 6.3% over those in the tube with the CRT alone. The highest thermal performance factor of 1.42 is found for the combined device consisting of the CRT with l/D 1.0 and TT with y/W 3. The correlations of the Nusselt number, friction factor and thermal performance factor of the tubes with combined devices are also developed in terms of Reynolds number, Prandtl number, twist ratio and pitch ratio.  相似文献   
5.
6.
Journal of Mechanical Science and Technology - Influence of spirally-corrugated tubes on heat transfer (Nu), pressure loss (f) and thermal enhancement factor (TEF) characteristics was numerically...  相似文献   
7.
This paper presents the effect of the circular-ring turbulator (CRT) on the heat transfer and fluid friction characteristics in a heat exchanger tube. The experiments were conducted by insertion of CRTs with various geometries, including three different diameter ratios (DR = d/D = 0.5, 0.6 and 0.7) and three different pitch ratios (PR = p/D = 6, 8 and 12). During the test air at 27 °C was passed through the test tube which was controlled under uniform wall heat flux condition. The Reynolds number was varied from 4000 to 20,000. According to the experimental results, heat transfer rates in the tube fitted with CRTs are augmented around 57% to 195% compared to that in the plain tube, depending upon operating conditions. In addition, the results also reveal the CRT with the smallest pitch and diameter ratios offers the highest heat transfer rate in accompany with the largest pressure loss.  相似文献   