首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   3篇
  免费   0篇
电工技术   1篇
无线电   2篇
  2022年   1篇
  2017年   1篇
  2008年   1篇
排序方式: 共有3条查询结果,搜索用时 15 毫秒
1
1.
Wireless Personal Communications - In this paper, we propose a new reputation approach, called I-WD (improved WatchDog). We attempt to eliminate selective dropping attack that ensue when malicious...  相似文献   
2.
This paper describes AMIRAS, an airborne demonstrator of the Microwave Imaging Radiometer with Aperture Synthesis, which is the instrument onboard ESA's Soil Moisture and Ocean Salinity (SMOS) mission. The main electrical, mechanical, thermal, and control elements of the demonstrator are shown, together with its capabilities and performances as demonstrator of the spaceborne instrument. AMIRAS main tests inside an anechoic chamber, field ground experiments, and its first two maiden flights are reported, and some results of these tests are highlighted. AMIRAS will further be used in some calibration and validation campaigns of the SMOS mission.  相似文献   
3.

Objective

A newly adapted zoomed ultrafast low-angle RARE (U-FLARE) sequence is described for abdominal imaging applications at 11.7 Tesla and compared with the standard echo-plannar imaging (EPI) and snapshot fast low angle shot (FLASH) methods.

Materials and methods

Ultrafast EPI and snapshot-FLASH protocols were evaluated to determine relaxation times in phantoms and in the mouse kidney in vivo. Owing to their apparent shortcomings, imaging artefacts, signal-to-noise ratio (SNR), and variability in the determination of relaxation times, these methods are compared with the newly implemented zoomed U-FLARE sequence.

Results

Snapshot-FLASH has a lower SNR when compared with the zoomed U-FLARE sequence and EPI. The variability in the measurement of relaxation times is higher in the Look–Locker sequences than in inversion recovery experiments. Respectively, the average T1 and T2 values at 11.7 Tesla are as follows: kidney cortex, 1810 and 29 ms; kidney medulla, 2100 and 25 ms; subcutaneous tumour, 2365 and 28 ms.

Conclusion

This study demonstrates that the zoomed U-FLARE sequence yields single-shot single-slice images with good anatomical resolution and high SNR at 11.7 Tesla. Thus, it offers a viable alternative to standard protocols for mapping very fast parameters, such as T1 and T2, or dynamic processes in vivo at high field.
  相似文献   
1
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号