首页 | 本学科首页   官方微博 | 高级检索  
     

低于GeCl4挥发温度的密闭消解-ICP-AES法测定AuGe2合金中Ge
引用本文:周建,朱利亚,李光俐,赵青,管有祥,谢宏潮,陈登权,陈亮维,安中庆,王应进.低于GeCl4挥发温度的密闭消解-ICP-AES法测定AuGe2合金中Ge[J].贵金属,2012,33(1):59-64.
作者姓名:周建  朱利亚  李光俐  赵青  管有祥  谢宏潮  陈登权  陈亮维  安中庆  王应进
作者单位:1. 昆明贵金属研究所稀贵金属综合利用新技术国家重点实验室,昆明,650106
2. 昆明理工大学,昆明,650224
基金项目:昆明贵金属研究所研究与发展基金资助项目
摘    要:提出了低于GeCl4挥发温度密闭消解AuGe2合金的新技术,研究了微波密闭消解和微波密闭消化罐室温溶解样品的条件,以及水合肼室温还原Au(Ⅲ)为Au(0)和电感耦合等离子体发射光谱法测定Ge的条件。结果表明:当功率600 W,温度70~80℃,压力3238~3652 kPa,升温5 min,恒温1~2 h或室温4~6 h时,9 mL HCl-3 mL H2O2能完全消解或室温溶解0.10 g样品,且Ge无损失。于约15%HCl介质中,水合肼室温能完全还原Au(Ⅲ)为Au(0)。当分析波长为209.426nm时,测定AuGe2合金中Ge的相对标准偏差0.882%和0.833%,样品加标回收率99.32%~100.71%,检出限0.0049μg/mL和线性范围1~506μg/mL。方法结果准确、分析快速、操作简便,已用于实际的样品分析,结果满意。

关 键 词:分析化学  密闭消解  低于GeCl4挥发温度  ICP-AES  合金  

Sealed Digestion -ICP -AES Determination of Germanium in AuGe2 Alloy at the Temperature Lower Then GeCl4 Volatilization
ZHOU Jian , ZHU Liya , LI Guangli , ZHAO Qing , GUAN Youxiang , XIE Hongchao , CHEN Dengquan , CHEN Liangwei , AN Zhongqing , WANG Yingjin.Sealed Digestion -ICP -AES Determination of Germanium in AuGe2 Alloy at the Temperature Lower Then GeCl4 Volatilization[J].Precious Metals,2012,33(1):59-64.
Authors:ZHOU Jian  ZHU Liya  LI Guangli  ZHAO Qing  GUAN Youxiang  XIE Hongchao  CHEN Dengquan  CHEN Liangwei  AN Zhongqing  WANG Yingjin
Affiliation:1(State Key Laboratory of Advanced Technologies for Comprehensive Utilization of Platinum Metals,Kunming Institute of Precious Metals,Kunming 650106,China;2.Kunming University of Science & Technology,Kunming 650224,China)
Abstract:A new technology of sealed digestion AuGe2 alloy at the temperature lower than GeCl4 volatilization temperature was proposed.Conditions for microwave sealed digestion and room temperature dissolution of samples by microwave sealed digestion were studied.At the same time,conditions for reduction of Au(Ⅲ) to Au(0) at room temperature by hydration hydrazine and determination of Ge by inductively coupled plasma atomic emission spectrometry were studied.Results indicate that the sample of 0.1 g is digested or room temperature dissolution completely by 9 mL HCl and 3 mL H2O2 solution when working parameters of microwave oven or microwave sealed digestion are as following: power 600 W,temperature 70~80℃,pressure 3238~3652 kPa,ramp 5 min and holding time 1~2 h or room temperature 4~6 h.None of Ge is lost.Au(Ⅲ) was reduced to Au(0) at room temperature by hydration hydrazine with 15% HCl.The relative standard deviations of determination of Ge in AuGe2 alloy were 0.882% and 0.833% when analytical line was 209.426 nm,recoveries of added standard Ge were 99.32%~100.71%,detection limit of Ge was 0.0049 μg/mL and linear range of Ge was 1~506 μg/mL.The proposed method was accuracy,rapid,convenient and has been applied to determination of Ge in actual sample with satisfactorily results.
Keywords:analytical chemistry  sealed digestion  lower then the temperature of GeCl4 volatilization  ICP-AES  alloy  germanium
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号