首页 | 本学科首页   官方微博 | 高级检索  
     

高寒高海拔地区1 000 kV变电站电气设备选择及布置方案
引用本文:文卫兵,康鹏,刘菲,胡君慧,官澜,张飞,应捷.高寒高海拔地区1 000 kV变电站电气设备选择及布置方案[J].中国电力,2018,51(11):61-66.
作者姓名:文卫兵  康鹏  刘菲  胡君慧  官澜  张飞  应捷
作者单位:1. 国网经济技术研究院有限公司, 北京 102209;2. 中国电力工程顾问集团西北电力设计院有限公司, 陕西 西安 710075
基金项目:国家电网有限公司科技项目(特高压交流输变电工程设计优化研究,B3440916K001)。
摘    要:高海拔、低气温均会对1 000 kV变电站设备选择和布置方案产生较大影响。目前尚没有在上述环境条件下的特高压变电站设计、建设经验以及相关的技术储备。通过调研设备制造水平及工程运行情况,结合实际需求,对不同的技术方案进行比较后,提出了–45℃、海拔3 500 m以下1 000 kV设备的外绝缘修正建议方法、1 000 kV设备套管建议型式、GIS伴热带设置原则;通过技术经济比较,提出了推荐的设备布置方案。其结论可供后续1 000 kV变电站建设参考。

关 键 词:特高压交流  1000kV  变电站  电气设备  选择  布置  高海拔  低气温  
收稿时间:2017-10-30
修稿时间:2018-06-14

Type Selection and Layout Plan of 1 000 kV Substation Electrical Equipment in Cold and High Altitude Areas
WEN Weibing,KANG Peng,LIU Fei,HU Junhui,GUAN Lan,ZHANG Fei,YING Jie.Type Selection and Layout Plan of 1 000 kV Substation Electrical Equipment in Cold and High Altitude Areas[J].Electric Power,2018,51(11):61-66.
Authors:WEN Weibing  KANG Peng  LIU Fei  HU Junhui  GUAN Lan  ZHANG Fei  YING Jie
Affiliation:1. State Grid Economic and Technological Research Institute Co., Ltd., Beijing 102209, China;2. Northwest Electric Power Design Institute Co., Ltd. of China Power Engineering Consulting Group, Xi'an 710075, China
Abstract:High altitude and low temperature will have a significant impact on type selection and layout of 1 000 kV substation equipment. At present, there are no design and construction experiences as well as related technical reserves for UHV substations under such ambient conditions. Based on an investigation of the current equipment manufacturing level and the operation conditions of existing projects in such environment, and after a comparison of different technical schemes, the paper proposes the external insulation correction method for 1 000 kV equipment, the type of 1 000 kV equipment bushing and the installing principle of heating belt for GIS under the ambient temperature of –45℃ and below the altitude of 3 500 m. The recommended equipment layout scheme is presented through technical and economic comparison. The research results can provide a reference for construction of the follow-up 1 000 kV substations.
Keywords:UHV AC  1 000 kV  substation  electrical equipment  selection  layout  high altitude  low temperature  