首页 | 本学科首页   官方微博 | 高级检索  
     

气化炉拱顶炉壁超温原因分析与处理
引用本文:欧勇,丁鸿吉,魏海峰.气化炉拱顶炉壁超温原因分析与处理[J].大氮肥,2014(4):247-249.
作者姓名:欧勇  丁鸿吉  魏海峰
作者单位:中国石油兰州石化公司化肥厂,甘肃兰州730060
摘    要:分析合成氨装置气化炉长期以来存在的拱顶炉壁超温的原因,针对原因对挂砖外形及气化炉烧嘴长度进行了调整,解决了拱顶炉壁超温的问题。

关 键 词:气化炉  超温  炉砖  烧嘴

ANALYSIS AND SOLUTIONS FOR OVERHEATING ABOUT DOME WALL OF GASIFIER
Ou Yong,Ding Hongji,Wei Haifeng.ANALYSIS AND SOLUTIONS FOR OVERHEATING ABOUT DOME WALL OF GASIFIER[J].Large Scale Nitrogenous Fertilizer Industry,2014(4):247-249.
Authors:Ou Yong  Ding Hongji  Wei Haifeng
Affiliation:( PetroChina Lanzhou Branch ,LanZhou 730060)
Abstract:The causes of overheating on dome wall, which had been existed on two gasifiers of amonia synthesis plant in CNPC Lanzhou Petroleum Chemical Industrial Co. for a long time, were analysed. With respect to these causes, the shape of furnace brick and length of gasifier burner were adjusted, which solved the problem of overheating effectively.
Keywords:gasifier  overheating  furnace brick  burner