国外500kV变压器过励磁保护的分析
引用本文:杨彪,董建达,金乃正.国外500kV变压器过励磁保护的分析[J].电力系统保护与控制,2004,32(13):71-73,81.
作者姓名:杨彪  董建达  金乃正
作者单位:绍兴电力局,浙江 绍兴 312000
摘    要:根据国外过励磁保护在绍兴电力局500kV变电站的应用情况,以500kV凤仪变#3主变ABB过励磁保护为例,着重分析了其基本原理、与变压器过励磁特性曲线的配合、存在的保护死区以及整定调试等问题。

关 键 词:变压器    过励磁    曲线    保护    整定    调试    死区
文章编号:1003-4897(2004)13-0071-03

Analysis of imported overexcitation protection in 500 kV power transformer
YANG Biao,DONG Jian-da,JIN Nai-zheng.Analysis of imported overexcitation protection in 500 kV power transformer[J].Power System Protection and Control,2004,32(13):71-73,81.
Authors:YANG Biao  DONG Jian-da  JIN Nai-zheng
Abstract:The application of imported overexcitation protection in Shaoxing 500 kV substation is introduced. Taking overexcitation protection from ABB employed in Fengyi 500 kV No.3 transformer as an example, the paper focuses on the principle of overexcitation protection, its cooperation with overexcitation characteristic curves, its protection dead zone, and relevant debugging.
Keywords:power transformer  overexcitation  curves  protection  coordination  debugging  dead zone  