1.
采用固体核径迹探测器和热释光剂量计,对成都市城镇和乡村的室内氡浓度与γ剂量率进行了测量。按测量时间、建筑结构、楼层、墙体建筑材料以及墙体装修材料对测量结果进行了比较分析。结果表明:成都市城镇和乡村室内氡浓度的均值分别为(39.5±18.1)Bq/m3和(38.2±16.3)Bq/m3,均低于世界平均水平;城镇和乡村的γ剂量率均值分别为(120.1±16.1) nSv/h和(124.4±16.7) nSv/h,与氡浓度无相关性。研究发现夏季室内氡浓度较高;低层建筑室内氡浓度受周围环境影响较大,高于高层建筑,并且随着楼层的增高室内氡浓度降低;墙体建筑材料和墙体装修材料对室内浓度有显著影响。  相似文献   

2.
李晓燕  郑宝山  王燕  王学 《辐射防护》2007,27(6):368-374
采用α径迹蚀刻法,对全国23个城市的234个地下人防工程测点的空气中氡浓度进行了调查测量.测量采用固体核径迹探测器(CR-39),采样分不同季节进行,每次采样暴露3个月.调查测量结果表明,234个测点的氡浓度范围为14.9~2 482 Bq·m-3,算术平均值为247 Bq·m-3;如以城市为统计单位,福州和包头的地下工程氡浓度较高,分别为714 Bq·m-3和705 Bq·m-3;广州和上海氡浓度较低,分别为71.1 Bq·m-3和72.6 Bq·m-3.在夏、冬两季测量数据齐全的21个城市中,除郑州、上饶、包头三城市外,其它18个城市地下工程中氡浓度呈夏季高于冬季.地下工程的地质背景、被覆程度、被覆(装修)材料和通风状况是影响地下工程空气中氡浓度的主要因素.  相似文献   

3.
本文报道1983—1990年由国家环境保护局组织的我国部分地区空气中氡及其子体α潜能浓度调查(试点)的方法和初步结果。全国15省选择21个城市以及部分特殊地点(包括部分煤渣砖房、人防工程地下室、海滨、水面和溶洞等)开展了此项调查。调查采用瞬时测量(有双滤膜法、闪烁法、气球法、活性炭吸附解析法)和累积测量(固体经迹蚀刻法)两种方法。考虑到长时间的平均浓度对评价氡吸入危害更有意义,并注意到我国北方农村特殊居室——窑洞和某些高寒城市肺癌发病率可能较高的情况,在调查后期,还组织了专门力量,用固体经迹探测器 CSR,对延安窑洞和哈尔滨居民室内氡浓度进行了测量。调查中室外测点尽量与大气常规监测同位,室内测点注意选取不同的建筑物类型。调查结果表明:(1)这些城市室外平均氡浓度均值范围为(3.3-40.8)Bq·m~(-3)子体α潜能浓度均值范围为(1.54—11.4)×10~(-8)J·m~(-3);(2)室内平均氡浓度范围为(7.5—170.8)Bq·m~(-3),子体α潜能浓度均值范围为(3.0—45.5)×10~(-8)J·m~(-3);(3)在武汉东湖、浙江千岛湖和辽宁大伙房水库三个水面,氡浓度均值分别为4.63、5.50和2.2 Bq·m~(-3),氡子体的等效平衡氡浓度均值分别为3.20、3.62和0.88 Bq·m~(-3),氡子体对水面上方空气吸收剂量率的贡献,分别为1.0、1  相似文献   

4.
杨志杰  赵荣  王南萍 《辐射防护》2018,38(4):275-280
为了研究北京地区浅层土壤氡浓度随深度变化的关系,利用RAD7电子测氡仪对北京市通州区、丰台区、门头沟区和延庆县的9个测点进行了野外现场测量并采集了土壤样品。测量了各测点浅层深度20、40、60、80和100 cm处的土壤氡浓度,使用室内高纯锗γ能谱仪对采集的样品进行土壤中镭含量分析。通过分析得出,在浅层深度(0~100 cm)范围内土壤氡浓度随土壤深度的增加呈现上升的趋势,土壤氡浓度与土壤样品镭含量之间趋于正相关关系;对比砂质土壤和粘质土壤氡浓度,得出在土壤镭含量水平相当的情况下,粘质土壤氡浓度比砂质土壤氡浓度高。  相似文献   

5.
在台湾的台北和花莲同时对10个测点的建筑物内和建筑物外进行了~(222)Rn(氡)及其子体的浓度和环境γ剂量率测量。台湾夏季氡的室内浓度估计约为20Bq·m~(-3),环境γ剂量率约为90nSv·h~(-1);室外相应地约为10Bq·m~(-3)和约70nSv·h~(-1)。计算出的平衡因子室内为0.2~0.3;室外为0.3~0.4。室内氡浓度与γ剂量率呈弱正相关。台湾可能在冬季因住宅通风率非常差而导致室内氡浓度增高。为了今后评估年有效剂量,需要在冬季1~2月份进行补充测量。  相似文献   

6.
某铀矿区居民室内外氡浓度调查及剂量评价   总被引:1,自引:0,他引:1  
李素云  张升慧 《辐射防护》1993,13(4):265-273
采用固体径迹探测器对某铀矿区附近居民室内外氡浓度进行了调查。对80户室内测点及25个室外测点的测量数据的统计结果表明,居民室内外氡浓度年均值(±单次测量标准差)分别为32.9(±12.1)及26.3(±18.0)Bqm~(-3)。室内外平衡因子分别为0.45和0.47。室内外氡子体照射所致成年人平均年有效剂量分别为1.02及0.32 mSv。  相似文献   

7.
本项研究的目的是对得克萨斯室内氡浓度区域分布特点与含铀岩石带和地方人口分布关系进行比较研究。得克萨斯产生较高氡气的岩石是西北地区的页岩和砂岩;北中部的红层;西部地区的长英质火山岩以及中部的砂岩、石灰岩和火成岩。在西北地区评价了202个乡镇,其中只有位于得克萨斯西北部的5个乡镇的平均室内氡浓度高于0.148Bq·L~(-1)。而这些乡镇中有2个乡镇的人口高于该州20115人这一平均值。最高的乡镇平均氡浓度是0.326Bq·L~(-1)。研究结果表明:(1)在得克萨斯,区域地质条件影响室内氡浓度;(2)就整个州来说,氡浓度是相对低的;(3)人口密集的乡镇并不与室内高氡浓度相一致;(4)须进一步监测的地区是西北地区,其次是西部和中部地区。  相似文献   

8.
全国室内氡-土壤氡关联性研究课题启动   总被引:3,自引:0,他引:3  
介绍了“全国部分城市室内氡-土壤氡关联性研究”课题的主要内容和相关技术要求。工作内容包括:室内氡浓度、土壤氡浓度、城市区域性土壤氡浓度调查;技术要求包括:室内氡调查布点要求、室内氡浓度连续测量要求、土壤氡测量方法、以及测量数据的处理。  相似文献   

9.
介绍了“全国部分城市室内氡.土壤氡关联性研究”课题的主要内容和相关技术要求。工作内容包括:室内氡浓度、土壤氡浓度、城市区域性土壤氡浓度调查;技术要求包括:室内氡调查布点要求、室内氡浓度连续测量要求、土壤氡测量方法、以及测量数据的处理。  相似文献   

10.
本文报道1984年7月至1985年6月间在本院实验室内测定的氡、(气土)浓度随季节和昼夜变化的情况。结果表明氡浓度的昼夜变化为早晨6—7时较高,下午1—3时较低,最高与最低值之比达3—4倍,接近日平均水平的时间为上午8—11时;氡、(气土)浓度随季节的变化规律相似,都是冬季(1—3月)较高,夏季(6—9月)较低,氡、(气土)月平均浓度的最高和最低值之比,分别为7.0和5.0倍,春(4—5月)、秋季(10—12月)的氡,(气土)浓度都分别与其年平均水平接近。  相似文献   

11.
原环保部2014年对湖南衡阳272尾矿库及周边进行了航测,意外发现在尾矿库西南方向、湘江上游附近有一辐射水平异常区域,后经调查该地区为车江铜矿地区。为了调查车江铜矿这一非铀矿山及其周边的氡活度浓度水平与氡的来源,采用了固体核径迹法与活性炭盒法对其氡活度浓度和氡析出率展开测量,并将氡析出率连续测量与活性炭盒法所测氡析出率结果进行对比分析。调查发现,该区域所有取样点位冬季和夏季氡活度浓度测量结果平均值分别为31.0 Bq·m-3和22.9 Bq·m-3;从区域分布上来看最高的均为农田区,其次为原采矿区。土壤氡析出率测量结果最高的同样为农田区,但是均远低于铀尾矿的氡析出率限值0.74 Bq·m-2·s-1。氡活度浓度日变化趋势与氡析出率的日变化趋势较为一致。上述结果表明车江铜矿地区的室外氡活度浓度较高与其土壤氡的析出有关。  相似文献   

12.
采用固体核径迹法,对成都市不同建筑类型、建筑结构、装修材料以及不同楼层的100间居室进行了室内氡浓度测量。调查结果表明:成都市居室环境中氡浓度的最高值为177.1 Bq/m3,最低值为8.4 Bq/m3,算术平均值为(39.4±22.9)Bq/m3;不同类型房屋室内氡浓度水平有显著差异;氡及其子体照射所致的人均年有效剂量为0.99 mSv,低于世界平均水平。  相似文献   

13.
Accelerator based ion beam analysis (IBA) techniques were used to determine the elemental composition of aerosol samples from four sites near Sydney, Australia. Hourly measurements of atmospheric Radon-222 (radon) concentration were made at the same sites. We evaluate a new method for quantifying the degree of distribution of aerosol sources based on the correlation analysis of two consecutive years (2007-2008) of IBA and radon data.Seasonal cycles and trends in concentrations of key elemental constituents of the sampled aerosols are characterised, and explained in terms of the regional Sydney climatology and proximity of measurement sites to the coast. Site-to-site correlation analysis was then undertaken between elements to quantify the extent to which a source had a regional impact or was only local to a site (site-specific). This was followed by correlation analysis of elements and radon at each site to identify the degree of spatial and temporal uniformity of the source at each site.Silicon concentrations (usually associated with soil sources), were overall well correlated between three of the four sites, indicative of a regional source for three sites and a local source for the fourth site. Conversely, the highest sulfur correlations were observed between sites that were closest together.On a site-by-site basis, radon was well correlated with black carbon and potassium and particularly during winter when domestic heating constitutes a distributed source. However, in summer the correlation of radon with BC and K was poor indicating that the distribution of these sources varies over the summer fetch region. Radon was also positively correlated with silicon and titanium, but the correlation coefficient for the entire data set was smaller than for black carbon. In summer and winter, when fetch regions were constrained by the prevailing meteorology, silicon and titanium showed a better correlation with radon. A small negative correlation was seen between sodium (a marker for sea salt) and radon.  相似文献   

14.
利用驻极体提高测氡灵敏度的研究   总被引:3,自引:1,他引:2  
铀矿井、某些非铀矿井和室内外的氡监测以及铀尾矿堆和建筑材料氡析出率的测量,是职业和环境辐射卫生评价的重要内容。利用驻极体在被动采样小室内产生收集氡子体的静电场,极大地提高了氡监测的灵敏度,测氡暴露量的探测下限为6.4Bq/m~3·h~(-1),采样周期为2d时,测氡浓度的探测下限为0.13Bq/m~3,采样周期为1h时测氡析出率的探测下限为0.55mBq/m~2·s。  相似文献   

15.
本研究采用以CR-39为探测元件的被动式累积测氡杯对广西省南宁市地铁1号线25个地铁站进行了为期一年的氡活度浓度累积测量。为确保测量结果准确性,采用CR-39暴露本底代替裸片本底,并在操作上将提供暴露本底的本底测氡杯始终置于密闭真空状态,进行了严格的质量控制。测量结果显示,25个地铁站全年平均氡活度浓度为(13.9±3.7)Bq/m3;分布范围是(6.4~32.9)Bq/m3。冬季平均氡活度浓度(18.1±2.2 Bq/m3)明显高于春(12.7±1.9 Bq/m3)、夏(12.9±3.5 Bq/m3)、秋(12.4±4.4 Bq/m3)三季;没有观察到地下一层和地下二层氡活度浓度水平有统计学意义的显著差异;没有观察到各地铁站之间氡活度浓度有统计学意义的显著差异。  相似文献   

16.
采用示踪气体稀释法测量不同房间状态(开关门窗、空调和风扇)下的居室换气率,同时利用RAD7、BWLM-PLUS氡子体测量仪连续测量室内的氡及其子体浓度,探讨换气率对室内氡及其子体浓度的影响。实验结果表明:在关门窗和关门窗开空调房间状态下,房间换气率和室内氡浓度无明显差异,室内氡浓度均高于开门窗和开门窗同时开风扇的房间状态;开门窗和开门窗同时开风扇的房间状态下房间的换气率比较大,室内氡及其子体浓度基本接近外环境水平。因此,现代生活中,尤其夏季,以空调制冷的方式取代了开门窗和开风扇的生活方式,势必导致室内氡浓度的增高。  相似文献   

17.
To find out the impacts of soil characters on radon concentrations in soil and radon exhalation from soil, field measurements on soil radon concentrations (60 cm under the soil surface) and radon exhalation rate from soil surface were carried out in totally 31 points with different types of soil in three cities in both South and North China. Soil radium contents, water contents, soil porosity and grain size were concretely analyzed in our laboratory. The linear simulation was used to analyze the above data. The results showed that radon exhalation rate from soil and radon concentrations in soil have direct proportion to soil radium contents. Rather high radium content and radon exhalation rate were measured in Guiyang area, 67±28Bq/kg and 40±59mBq/m2-s, however no high soil radon concentration was found due to the difficulties in the measurements on clay soils with high water saturation. Compared with soil radium contents, radon exhalation rate from soil and soil radon concentrations are more easily impacted by soil characters and change in a rather large range.  相似文献   

18.
重庆市氡浓度水平调查   总被引:1,自引:0,他引:1  
对重庆市主城区环境空气、房地产建筑工程场地、伴生放射性矿堆场和宾馆室内空气氡浓度进行了调查。调查结果表明:主城区在12个区24个测点的环境空气中氡浓度年均值为10.8Bq/m3;房地产建筑工程场地土壤中的氡浓度按6个工地统计均值为1193Bq/m3;不同伴生矿的矿堆场周围空气中氡浓度水平差异很大,其中萤石矿最大,其次是铅锌矿;堆场周围空气中氡浓度水平按10类被调查的矿种统计平均值为65.2Bq/m3,萤石矿堆场周围空气中氡浓度平均值369Bq/m3,约是全市区域环境空气中氡浓度的35倍;8家宾馆109个客房室内氡浓度年均值为32.9Bq/m3。  相似文献   

19.
为科学确定地下工程氡防护措施,本文根据地下工程氡防护经验,梳理了典型氡防护方法,并通过实际测量和性能实验,评价各种氡防护方法。结果表明,通风降氡是地下工程降氡普遍方法,对12000 m^(3)空间按照2 m^(3)/s风速通风1小时能够降低空气中氡浓度三分之一左右;吸附降氡能够对人员活动集中区域进行局部降氡,采用自研的移动降氡装置工作2小时能够使80 m^(3)含氡空气的氡浓度降低55%左右;屏蔽降氡能够对高氡析出率区域进行重点降氡,采用聚酰亚胺树脂防氡材料能够使阻氡效率大于99.5%。不同降氡方法都有其适用范围和优缺点,应根据地下工程实际情况进行优化设计。  相似文献   