首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 148 毫秒
1.
结合太原市某污水厂近二年运行数据(2013~2015年),分析了改良型A~2O工艺中污染物转化的空间分布规律,如COD、NH_3-N、TP,定量分析了脱氮的途径和贡献比例,提出脱氮主要发生在缺氧区以及污泥前置反硝化区。通过进一步实验排除了硝化程度、回流点位置、缺氧区容积(HRT)对脱氮限制,提出内回流比、回流带入DO对反硝化效率的抑制,并通过调整内回流比使出水TN达到一级A标准。  相似文献   

2.
A2O工艺处理低C/N比生活污水的试验研究   总被引:12,自引:2,他引:10       下载免费PDF全文
吴昌永  彭永臻  彭轶 《化工学报》2008,59(12):3126-3131
采用52.5 L的A2O试验装置处理实际生活污水,研究了A2O工艺在处理低C/N比生活污水时的脱氮除磷特性,并探讨了如何通过强化缺氧吸磷来提高系统的脱氮除磷效率。试验结果表明:在厌氧/缺氧/好氧体积比为1/1/2、HRT为8 h、污泥回流比为70%、内回流比为300%的工况下处理C/N为7.89的生活污水,TN和SOP去除率分别能够达到85.4%和93.3%,系统中存在反硝化除磷,缺氧吸磷占总吸磷量的25.3%。同样的运行条件下处理C/N为4.20的生活污水时,SOP去除几乎不受影响,但TN去除率降低至62.2%,平均出水TN浓度也超过20 mg•L-1。维持厌氧区体积不变,增大缺氧区体积,使得缺氧/好氧体积比为5/8时,TN去除率可上升到70.7%,缺氧吸磷占总吸磷量的55.2%。同时改变内回流比的试验表明250%的内回流比能最大程度地强化反硝化除磷的作用,此时TN去除率可提高至77.3%。强化A2O工艺中的反硝化除磷,能克服碳源不足对脱氮除磷的影响,显著提高低C/N比污水的脱氮除磷效率。  相似文献   

3.
以福建某污水厂污水为对象进行中试规模的研究,探讨回流比对一体化厌氧/缺氧/好氧膜生物反应器AAO-MBR污水处理装置脱氮除磷的影响。结果表明:好氧区至缺氧区回流(R1)对NH3-N的去除影响较小,过高和过低的R1均会影响TN和TP的去除,当R1=1︰1时,系统脱氮效果最佳。缺氧区至厌氧区回流(R2)对系统脱氮影响很小,较低的R2(R2=0.5︰1)更利于系统除磷。  相似文献   

4.
通过中试实验研究了三级组合生物滤池强化脱氮效果,考察了第二级好氧滤柱回流比对工艺前置反硝化的影响,第三级滤池外加碳氮比对后置反硝化强化脱氮效果的影响。结果表明,在进水流量为0.5 m~3/h,水温为18℃左右,第二级好氧滤柱气水比为3:1时,在回流比为100%时,前置反硝化脱氮能达最佳效果,TN去除率为54.07%,出水TN浓度平均值为19.94 mg/L,不同回流比下,COD、NH_4~+-N均有较高去除率。为进行强化脱氮,在第三级缺氧滤柱前投加碳源,碳氮比为7:1时,第三级对TN去除率为40.7%,出水TN平均值为11.84 mg/L。三级组合生物滤池结合前置和后置反硝化工艺对TN有很好的去除效果,稳定运行后,系统对TN平均去除率达到72.96%。  相似文献   

5.
王志辉  翟敏 《河南化工》2010,27(16):115-116
介绍了马头岗污水处理厂为提高脱氮效率,从影响脱氮的两个主要因素内回流比和碳源着手,对生物池原UCT工艺进行升级改造为前置缺氧A2O工艺,以提高反硝化能力;同时,又对改造后的工艺运行进行优化,以达到TN出水控制在15 mg/L以下。  相似文献   

6.
针对安宁市某污水处理厂低负荷污水的运行现状,通过序批式活性污泥法(SBR)中试模拟,对在不同污泥含量下系统脱氮除磷效果和不同回流方式(方式1为SBR池回流至生物选择区,方式2为SBR池回流至缺氧池后再回流至生物选择区)状态下的系统脱氮除磷效果进行分析。结果表明,污泥的质量浓度在4~5 g/L时,系统脱氮除磷效果为佳,TN、TP的去除率分别为46.52%、25.16%。回流方式1和方式的2的TP平均去除率分别为46.47%和56.99%,方式2除磷效果优于方式1;而脱氮效果无显著差异(TN的去除率分别为44.23%和49.10%)。  相似文献   

7.
改良A^2/O工艺脱氮除磷研究   总被引:1,自引:0,他引:1  
实验研究了污泥回流比和混合液回流比对改良A2/O工艺脱氮除磷的影响.预缺氧池能够让NO3--N在进入厌氧池前被完全反硝化,保证磷的正常释放.污泥回流比对整个系统的处理效果影响较大,污泥回流比减小,生物反应器中的细菌数量会逐渐减少,出水水质变差;污泥回流比过大,系统处理效果也会变坏,实验采用50%、100%和150%污泥回流比,污泥回流比为50%时脱氮除磷效果最好.混合液回流比为200%、300%和400%对TN、TP的去除研究表明:混合液回流比增大为反硝化提供了更多的基质,从而提高总氮的去除效果,但是随着混合液回流比进一步增加,不会提高氮的去除效果,反而使能耗大大增加.因此,运行条件优选为污泥回流比为50%,混合液回流比为200%.  相似文献   

8.
对上向流曝气生物滤池(UBAF)前置反硝化工艺处理城市污水的脱氮性能进行了试验研究,探讨了在不同回流比下,系统对COD、TN、NH3-N的去除效果。试验结果表明:当回流比从100%增加到300%时,对COD和NH3-N的去除率有着缓慢的增加,但当回流比增加到400%时,COD和NH3-N的去除率开始下降;回流比对TN的去除影响显著,在一定范围内增大回流比有利于TN的去除,当回流比为200%时,对TN的去除效果最好;在最佳回流比200%下,系统对COD、NH3-N和TN平均去除率分别为92.53%、93.50%和79.79%,出水COD、NH3-N和TN的平均质量浓度分别为17.70、2.12和11.36 mg/L,均能达到《城镇污水处理厂污染物排放标准》(GB 18918—2002)的一级标准。  相似文献   

9.
针对农村分散型污水处理技术对高脱氮率、低能耗和运行简便的要求,研究开发了一种气升回流式一体化接触氧化反应器,利用曝气,使回流管内外产生液体密度差异,实现回流,简化操作。考察了不同回流区域、进水碳氮比、回流比条件下的TN去除效果。结果表明,在出水水质指标SS含量、COD和NH4+-N达标的前提下,回流区域从缺氧二区变为缺氧一区,TN去除率从30%升至50%;随m(C)/m(N)从3:1升至5:1,TN去除率增加5%~10%;当回流体积比从0:1(没有回流)升至3:1,TN去除率从20%~30%升至65%~75%,但当回流体积比升至2:1(m(C)/m(N)=3:1)或2.5:1(m(C)/m(N)=5:1)以上时,TN去除率开始下降。因此,适宜的回流区域为缺氧一区、回流体积比为2:1。  相似文献   

10.
针对某污水厂改良型Carrousel氧化沟工艺运行中全氮去除率较低的工况,研究了溶氧浓度、C/N比、污泥龄、污泥回流比、温度等因素对其同步脱氮的影响,提出优化运行方案.结果表明,优化方案为根据相应位点溶氧浓度变化调控表曝机输出功率,降低系统能耗;改厌氧区单点进水为厌氧区、前置缺氧区双点进水,提高缺氧区C/N比.改造后,系统对COD,BOD5,NH4+-N去除效果稳定,全氮去除率从56.25%提高到68.80%.  相似文献   

11.
试验以A^2/O工艺为研究对象,动态模拟实际污水处理厂的运行情况,对该工艺连续动态监测了40h。研究结果表明,进水流量和进水水质变化对系统的去除效果并未产生较大影响,有机物、氨氮和磷的平均去除率可分别稳定在83%、98%和98%左右,这表明系统具有较强的抗冲击负荷能力;但对脱氮率和聚磷菌的厌氧释磷量会产生较大的影响;在同一连续流反应装置中同时实现了较为明显的缺氧吸磷和同步硝化反硝化作用,曝气量和碳源需求量可分别节省15.1%和11.5%。  相似文献   

12.
采用实验室规模连续流厌氧-缺氧-好氧(A/A/O)工艺处理人工模拟生活污水,考察了不同碳氮比(C/N)和溶解氧(DO)工况下改变缺氧池容积对A^2/O工艺脱氮除磷效果的影响。结果表明,在低C/N和好氧阶段DO含量较低时,增大缺氧池容积有利于提高TN的去除率和除磷效率,在COD/ρ(TN)(ρ(TN)≈40 mg/L)约为7,DO的质量浓度在0.9~1.2 mg/L的条件下,缺氧池容积增加1倍,TN去除率可达71.1%,PO4^3--P去除率可达94.0%;在高C/N和好氧阶段DO含量较高时,增大缺氧池容积在提高TN去除率和改善出水水质方面效果不显著。  相似文献   

13.
曹亚丽  王霞  胡凯  孙杏  侯克锁 《净水技术》2022,41(2):58-62,86
水力停留时间(HRT)是影响AAO工艺脱氮除磷效率的重要因素.采用改良型AAO-MBR工艺处理某农村生活污水,考察了夏季时HRT对处理装置出水效果的影响.试验结果表明,该工艺对低浓度农村生活污水中CODCr、氨氮的去除效果较稳定,平均去除率分别为69.50%、98.90%.TN去除率为26.50%~56.60%,随厌氧...  相似文献   

14.
引言 随着水体富营养化问题的日渐突出,污水处理技术逐渐从单一去除有机物为目的的阶段进入既要去除有机物又要脱氮除磷的深度处理阶段[1].  相似文献   

15.
采用厌氧与交替缺氧和好氧技术相结合的A2/O工艺处理医院综合污水,取得了很好的效果.该工艺与传统的活性污泥法A2/O工艺相比有更多的优点,总氮去除率86.1%,NH3-N去除率92.9%,磷去除率82.2%,节能16.6%,处理后的综合污水各项指标均达到了医院现行排放标准的要求.  相似文献   

16.
In order to enhance phosphorus removal in traditional step-feed anoxic/oxic nitrogen removal process,a modified pilot-scale step-feed anaerobic/anoxic/oxic (SFA2/O) system was developed,which combined a reactor similar to UCT-type configuration and two-stage anoxic/oxic process.The simultaneous nitrogen and phosphorus removal capacities and the potential of denitrifying phosphorus removal,in particular,were investigated with four different feeding patterns using real municipal wastewater.The results showed that the feeding ratios(Q1)in the first stage determined the nutrient removal performance in the SFA2/O system.The average phosphorus removal efficiency increased from 19.17% to 96.25% as Q1 was gradually increased from run 1 to run 4,but the nitrogen removal efficiency exhibited a different tendency,which attained a maximum 73.61% in run 3 and then decreased to 59.62% in run 4.As a compromise between nitrogen and phosphorus removal,run 3 (Q1=0.45Qtotal) was identified as the optimal and stable case with the maximum anoxic phosphorus uptake rate of 1.58mg·(g MLSS)-1·h-1.The results of batch tests showed that ratio of the anoxic phosphate uptake capacity to the aerobic phosphate uptake capacity increased from 11.96% to 36.85% with the optimal influent feeding ratio to the system in run 3,which demonstrated that the denitrifying polyP accumulating organisms could be accumulated and contributed more to the total phosphorus removal by optimizing the inflow ratio distribution.However,the nitrate recirculation to anoxic zone and influent feeding ratios should be carefully controlled for carbon source saving.  相似文献   

17.
采用一个缺氧/好氧MBBR反应器考察其对TN、NH3-N和有机物的去除,同时采用另一个缺氧MBBR反应器,考察其对NO3--N的去除。试验结果表明:当进水TN的质量浓度为150~300 mg/L,NH3-N的质量浓度为50 mg/L浓度时,缺氧/好氧MBBR对TN和NH3-N的平均去除率大于89.7%和84.0%,出水TN和NH3-N均能达到GB 21902—2008《合成革与人造革工业污染物排放标准》中规定的要求(ρ(NH3-N)8 mg/L,ρ(TN)15mg/L)。当碳氮比较低时,产生NO2--N的积累,对缺氧/好氧MBBR处理合成革废水而言,维持其碳氮比在3.5左右即可实现有效脱氮。缺氧MBBR反硝化能去除约98.2%的NO3--N和NO2--N,初始时碳氮比较低,产生NO2--N的积累,当碳氮比继续升高时,TN浓度下降,说明当NO3--N的质量浓度高达300 mg/L时,缺氧MBBR的反硝化效果显著。  相似文献   

18.
BACKGROUND: In this study, a plug‐flow A2O (anaerobic/anoxic/oxic) reactor, with a working volume of 52.5 L, was employed to investigate the performance of biological nutrients removal and microbial population variations when treating low C/N ratio domestic wastewater. RESULTS: Results showed that TN removal was significantly affected by the shortage of carbon source while phosphorus removal was only slightly affected. The effluent soluble orthophosphate‐phosphorus (SOP) concentration was lower than 0.50 mg L?1 but the TN concentration was over 20 mg L?1 when the C/N ratio was 4.43. There was denitrifying phosphorus removal in the anoxic reactor and this was enhanced by increasing the volume ratio of anoxic reactor and maintaining appropriate mixed liquor recycle rate. More than 60% of the SOP were removed in anoxic reactors by denitrifying phosphorus removal when the volume ratio of anaerobic/anoxic/oxic was 1/1.4/1.6 and the mixed liquor recycle rate was 250%. The TN concentration of effluent decreased to 11.34 mg L?1 and SOP concentration was still lower than 0.5 mg L?1 in this condition. The main microorganisms found in the process by polymerase chain reaction‐denaturing gradient gel electrophoresis (PCR‐DGGE) and the functional biodiversity are discussed. CONCLUSION: Traditional design and operating parameters of A2O are not appropriate for treating low C/N wastewater. Enhancing the denitrifying phosphorus removal ratio in an A2O process is an effective way to increase the removal rate of N and P from low C/N wastewater. Copyright © 2010 Society of Chemical Industry  相似文献   

19.
操家顺  陈洵  方芳 《净水技术》2013,(6):40-44,63
以采用厌氧/缺氧/好氧(A/A/O)工艺的城镇污水处理厂为研究对象,利用改良A/A/O中试装置开展处理实际污水的研究,通过与实际工艺的运行效果对比,系统探讨了低溶解氧(DO)浓度以及好氧池末端非曝气区的设置对脱氮除磷的影响。结果表明当好氧区的DO平均浓度从2.2mg/L逐渐降至1.0mg/L时,系统COD的去除效率与硝化效果未受到影响,但除磷效果明显下降;随着DO平均浓度的降低以及非曝气区对DO的缓冲,保证了缺氧区的缺氧环境,同时有效降低了内回流液中DO浓度的携带对碳源的消耗,提高了反硝化效率,使得系统对TN的去除率逐渐升高。就总体运行情况来看,A/A/O工艺中好氧区DO的平均浓度可以在1.0—2.0mg/L之间运行,同时在好氧区末端设置非曝气区,可以有效地缓冲内回流液中DO浓度对反硝化的影响,提高脱氮效率。  相似文献   

20.
试验以实际规模的污水处理厂为研究对象,针对传统CAST工艺脱氮效率不高的问题进行分析研究,采用改良的CAST工艺,在主反应区中增设独立的缺氧搅拌段,合理分配每周期的时间,充分利用原水中的碳源提高系统脱氮性能,TN去除率最多可提高19.4%,出水TN稳定达到一级A标准。考察了冬季低温条件下不同系统的脱氮情况,反硝化菌较硝化细菌对温度更加敏感,水温降到12℃时,反硝化效果受到明显影响,水温降至10℃以下时,硝化反应难以进行彻底,通过增加微生物浓度可改善低温下的脱氮效果,但是系统MLSS质量浓度不宜超过7 000mg.L-1。针对冬季低温提出适宜的运行模式,在MLSS质量浓度为(6 130±367)mg.L-1,曝气165 min的条件下可满足出水TN达到一级A标准并且沉淀较充分出水清澈。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号