1.
单调荷载下栓钉连接件受剪性能试验研究   总被引:3,自引:0,他引:3       下载免费PDF全文
栓钉是钢-混凝土组合梁中常用的柔性受剪连接件。通过18个栓钉受剪试件在单调荷载下的推出试验,较系统地研究了混凝土强度等级、栓钉直径以及钢梁类型等参数对栓钉的破坏形态、破坏机理、荷载-滑移规律和极限受剪承载力的影响。研究表明:栓钉的受剪承载力随着混凝土强度等级的提高以及栓钉直径的增大而增加;轧制工字钢试件中栓钉的受剪承载力比焊接工字钢试件中的高10%~30%。在试验的基础上提出了栓钉受剪承载力的计算方法。  相似文献   

2.
开孔板连接件受剪性能试验研究   总被引:4,自引:0,他引:4       下载免费PDF全文
开孔板连接件是钢-混凝土组合梁中常用的一种抗剪连接件。通过21个开孔板连接件试件在单调静力荷载作用下的推出试验,研究了开孔板的开孔直径、混凝土强度等级、孔中横向贯通钢筋的直径和数量等对开孔板连接件的破坏形态、荷载-滑移特性和受剪承载力等的影响。研究表明:开孔板连接件的荷载-滑移曲线(P-S曲线)大致可分为弹性阶段、塑性发展阶段和下降段;提高混凝土强度等级、增大开孔直径可提高开孔板连接件的受剪承载力,横向贯通钢筋直径由16mm增大至20mm时,试件的受剪承载力提高了21.8%,配置横向贯通钢筋2 16的试件受剪承载力比相应的未配置横向贯通钢筋的试件高19.1%;随着混凝土强度等级的提高,试件抗剪刚度增大,而开孔直径及横向贯通钢筋直径则对抗剪刚度无明显影响。最后,基于试验结果提出了开孔板连接件受剪承载力的计算方法。研究成果可为编制《钢-混凝土组合桥梁设计规范》提供依据和参考。  相似文献   

3.
In steel-concrete composite beams, the shear connectors are commonly used to transfer the longitudinal shear forces across the steel-concrete interface. This paper summarizes the results of 24 push-out test specimens with a new type of shear connector called “I-shape connector”. The test specimens were designed to study the effect of the following parameters on the ultimate load capacity: the height of I-shape connector, the length of I-shape connector, the compressive strength of concrete and the number of transverse reinforcing bars. The experimental results are presented and discussed, focusing on the failure modes and load-slip behaviour. Finally, the experimental results are compared to the existing design equations to predict the ultimate load capacity of I-shape shear connectors.  相似文献   

4.
为研究带双排栓钉的组合梁的纵向受剪性能,进行了7个带双排栓钉的钢-混凝土组合梁试件和1个带单排栓钉的钢-混凝土组合梁对比试件的纵向受剪试验。研究栓钉横向或纵向间距、横向配筋率、混凝土强度、栓钉排布方式等因素对带双排栓钉的钢-混凝土组合梁纵向受剪性能和混凝土板破坏形态的影响,并分析了各研究参数对峰值荷载和极限滑移量的影响。结果表明:带双排栓钉的钢-混凝土组合梁试件破坏模式主要表现为“八”字形裂缝的剪切破坏;栓钉横向、纵向间距、混凝土强度以及混凝土板配筋率是影响钢-混凝土组合梁受剪承载力的主要因素;受剪承载力均随着栓钉横向间距、纵向间距、混凝土强度以及混凝土板的横向配筋率的增加而增大。  相似文献   

5.
Four steel-concrete composite cantilever beam specimens were tested to investigate their mechanical behavior under negative moment induced by concentrated loads at the ends of the beams. The failure modes, serviceability and ultimate bearing capacities of the composite beams with full shear connection were studied. The crack initiation and propagation were investigated with consideration of two types of shear connectors. Three kinds of longitudinal reinforcement ratios were also examined. The experimental results indicate that an increase in the reinforcement ratio is beneficial to the bearing capacity of the composite beams to some extent and that the shear stud connector is superior to the steel block connector with regards to the serviceability of the beams. Two numerical models, which were based on a concrete material model and an elasto-plastic material model, were employed to simulate the behavior of steel-concrete composite beams. The numerical calculation results show that the combination of the two models can be used to predict the longitudinal cracking load and ultimate bearing capacity of composite cantilever beams. Based on the experimental and numerical results, it was found that the ultimate bearing capacity of a steel-concrete composite beam under negative moment can be significantly affected by longitudinal cracks in the concrete slabs. An equation to predict the longitudinal cracking load of a composite cantilever beam under negative moment by concentrated load was proposed and found to have good accuracy.  相似文献   

6.
Perforated shear connector with flange head (PSCFH) as a new type of connector behaves high bearing capacity and excellent ductility in steel-concrete composite girders. In this paper 15 groups, totally 45 push-out test specimens, were conducted to investigate the effects of plate thickness, connector height, flange length, flange number, hole diameter on the web, diameter of reinforcing bars and concrete strength on structural behaviour of PSCFH. In the push-out tests, failure mode, load versus slip curve and bearing capacity of all the specimens were obtained. Based on the results of push-out tests, bearing mechanism was analyzed and a calculation model of the shear bearing capacity was proposed with respect to the failure modes. Calculation results based on the proposed model agree well with the experimental values.  相似文献   

7.
通过对1个现浇和7个叠合整体式混凝土剪力墙足尺试件的轴心受压试验,考察了其在轴心荷载作用下的受力性能、破坏模态和承载力,分析高厚比、预制部分截面面积占全截面面积比例(预制率)和预制薄板板肋方向等因素对剪力墙试件轴心受压性能的影响。结果表明,叠合整体式混凝土剪力墙破坏模态分为叠合面开裂破坏和轴心受压破坏两种:叠合面开裂破坏前,有明显的开裂现象,破坏过程平缓,试件承载力较低;轴心受压破坏前,试件表面无明显的裂缝产生,破坏过程突然,承载力较高。墙体高厚比对试件的承载力影响不明显;预制率越高,压缩刚度越大,墙体竖向变形越小;预制薄板板肋对叠合墙受压性能影响较小。针对叠合整体式混凝土剪力墙轴心受压破坏模态,总结中、美两国规范及已有研究中的轴心受压构件承载力计算公式,给出了叠合整体式混凝土剪力墙的轴心受压承载力简化计算式,其计算值与试验值吻合较好。  相似文献   

8.
为了研究型钢与部分外包混凝土的在拉力作用下的纵向剪力传递性能,对6个部分外包钢-混凝土组合构件进行了轴拉试验,对其破坏形态和荷载-滑移曲线进行了分析。试验中主要考虑了型钢与腹部混凝土的黏结长度、混凝土强度、栓钉连接件数量等影响因素。研究结果表明:部分外包钢-混凝土组合构件破坏形态主要表现为黏结破坏、混凝土压碎和栓钉剪断;轴拉试验和推出试验中无栓钉连接的部分外包型钢混凝土组合构件的黏结力均随着型钢与混凝土间的黏结长度的增加而增大;对于无栓钉和有栓钉组试件,轴拉试验和推出试验中型钢与混凝土间的受剪承载力均随着混凝土抗拉强度的增加而增大,且近似成线性关系;部分外包钢-混凝土组合构件的受剪承载力随栓钉数量的增加而增大;相较无栓钉组试件,采用2根栓钉连接和4根栓钉连接的轴拉试件,其受剪承载力分别可提高近100%和250%。  相似文献   

9.
Behavior of channel shear connectors, Part I: Experimental study   总被引:1,自引:0,他引:1  
In composite beams, shear connectors are commonly used to transfer longitudinal shear forces across the steel-concrete interface. This paper presents an experimental study on the behavior of channel shear connectors embedded in a solid concrete material slab under monotonic and low-cycle fatigue loading. The latter would be applicable to composite structures subjected to seismic events. Of specific interest are the behavior and effects of different concrete materials. A series of push-out specimens made of plain concrete, reinforced concrete (RC), fiber reinforced concrete (FRC) and engineered cementitious composite (ECC) were tested for this evaluation. The results show that the reversed cyclic shear strength of most specimens is 10%-23% lower than their monotonic strength. Also, using the polypropylene fibers (FRC specimens) has a slight effect on the shear strength and load-displacement behavior of the specimens; however, using the polyvinyl alcohol fibers (ECC specimens) causes considerable increase in ultimate strength and ductility of channel shear connectors. Finally, the experimental load capacities are compared with that suggested by North American design codes.  相似文献   

10.
为研究方钢管钢骨混凝土柱与钢梁端板螺栓连接节点的抗震性能,进行了5个节点拟静力试验研究,分析了端板厚度、螺栓直径、混凝土强度和轴压比等因素对承载力、弯矩-转角曲线、耗能能力、承载力衰退、刚度退化、延性以及破坏模式的影响。研究结果表明:方钢管钢骨混凝土柱与钢梁端板螺栓连接节点均属于半刚性节点,初始转动刚度随着端板厚度和螺栓直径增大而提高,但节点的极限转动能力随着端板厚度的增大而减小;当承载力由端板或钢梁控制时,其具有良好的转动和耗能能力;试件承载力退化系数在0.8~1.0之间,变化幅度不大,刚度退化相比荷载退化严重;设计中应避免高强螺栓发生脆性破坏。  相似文献   

11.
在组合梁的设计中,剪力连接件一般用于将纵向剪力转移到钢-混凝土的连接界面。对单调低周疲劳荷载作用下混凝土板中的槽钢剪力连接件的性能进行了试验研究。这种混凝土板将应用于地震作用下的组合结构,其中不同混凝土材料的性能和作用成为了研究重点。对一系列由素混凝土、钢筋混凝土(RC)、纤维钢筋混凝土(FRC)和水泥基复合材料(ECC)组成的构件进行推出测试。结果显示:大部分构件的循环抗剪强度要比它们在单调加载条件下的抗剪强度低10%~23%。同时,聚丙烯纤维(FRC构件)的采用对构件的抗剪强度和荷载-位移曲线也产生影响。然而,聚乙烯醇(ECC构件)的采用在剪力连接件的极限强度和延性上引起了显著的增加。最后,对比了试验构件的承载能力与北美设计规范建议的数值。  相似文献   

12.
为研究装配整体式钢-混凝土组合梁中栓钉抗剪连接件的受力性能,设计了10个栓钉抗剪连接件,对其进行推出试验,得到了现浇混凝土板和预制混凝土板中栓钉抗剪连接件在单调和重复荷载作用下的界面剪力-滑移曲线以及破坏形态。结果表明:预制混凝土板中栓钉受剪承载力比现浇混凝土中栓钉受剪承载力略低,均为栓杆剪断和栓钉根部焊缝破坏;重复荷载作用下峰值界面剪力对应的界面滑移明显大于单调荷载作用下峰值界面剪力对应的界面滑移;重复荷载作用下的峰值界面剪力与单调荷载下的峰值界面剪力相当,其界面剪力-滑移曲线基本一致。  相似文献   

13.
在钢-混凝土组合梁加宽旧桥技术中,旧桥混凝土边梁与新加宽的钢-混凝土组合梁间的横向连接采用钢-混凝土组合横梁的形式,这种横梁形式较为新颖,目前相关试验研究尚未有报道。对6个钢-混凝土组合横梁进行试验研究,通过采用目前已有的新老混凝土植筋界面承载力计算方法对试验结果进行对比计算。研究结果表明:组合横梁界面的破坏模式为新老混凝土界面破坏,钢-混凝土界面没有任何破坏特征;新老混凝土界面黏结破坏以前,新老混凝土之间几乎没有滑移,整体性很强;新老混凝土界面黏结破坏以后,界面剪力主要由植筋承担,试件延性良好。针对钢-混凝土组合梁加宽旧桥技术中组合横梁的破坏模式,采用合理的材料本构关系,提出三阶段界面受力模型,理论方法计算结果与试验值吻合良好。通过理论分析确定界面的破坏机理:新老混凝土界面的极限抗剪强度由混凝土强度,界面粗糙程度和摩擦系数共同确定,界面正应力的存在有利于极限抗剪强度的提高;新老混凝土界面的残余抗剪强度主要由界面植筋提供,植筋率和植筋屈服强度是主要影响因素。最后,提出适用于实际工程的设计方法。  相似文献   

14.
基于传统钢-混凝土组合梁提出了一种节省钢材且具有较高抗剪承载力的新型组合梁——腹板嵌入式钢-混凝土组合梁,由倒T形钢梁腹板上部开槽,嵌入到混凝土翼板中形成。通过4个局部受压试件的试验得出,腹板嵌入式组合梁局部受压承载力随混凝土强度等级和局部荷载作用下扩散应力分布面积的增加而提高。综合各影响因素推导出了腹板嵌入式组合梁中连接件的局部受压承载力计算公式,并提出进行局部受压设计时对横向配筋率和应力扩散深度的构造要求。通过理论计算值与试验结果的对比,验证了公式的适用性。  相似文献   

15.
针对西部盐渍土地区钢筋混凝土桥梁墩柱的腐蚀问题,提出一种新型组合结构“钢骨架聚乙烯塑料复合材料(SRPE)套管约束混凝土柱”,该新型组合结构能够彻底隔离墩柱与各种腐蚀性离子的接触。为研究其轴心受压力学性能,对12个SRPE套管约束混凝土短柱试件及3个素混凝土短柱试件进行了轴心受压试验,分析了混凝土强度等级、SRPE套管环向约束应力和膨胀剂对试件的破坏形态、荷载-位移曲线、延性和初始压缩刚度的影响规律。根据SRPE套管环向约束应力计算方法和约束混凝土短柱抗压强度计算公式,建立了SRPE套管约束混凝土短柱轴心抗压强度计算方法。结果表明:SRPE套管约束混凝土短柱的最终破坏形态均为核心混凝土发生斜剪破坏,且随着SRPE套管环向约束应力的增高,试件的剪斜变形角逐渐减小; 试件混凝土强度等级越高,其荷载-位移曲线的峰值荷载越大,下降段更陡峭,试件的脆性越大; SRPE套管能够明显提高试件的承载力、峰值变形及延性,且随着SRPE套管环向约束应力的增大,试件各项力学性能均呈逐渐上升趋势; 提高混凝土强度等级,试件的承载力提高,但峰值变形和延性有所降低; 掺入膨胀剂(质量分数10%)使试件的承载力降低,而峰值变形、初始压缩刚度及延性则稍有提高; 所建立的轴心抗压承载力计算方法可为工程实践提供参考。  相似文献   

16.
高轴压比钢管混凝土剪力墙抗震性能试验研究   总被引:3,自引:0,他引:3       下载免费PDF全文
为研究约束边缘构件内配置圆钢管的钢管混凝土剪力墙的抗震性能、探讨钢管混凝土剪力墙的轴压比限值及其约束边缘构件的配箍要求,完成了6个剪跨比大于2.0的高轴压比钢管混凝土剪力墙试件和1个钢筋混凝土剪力墙试件的拟静力试验。试验结果表明:剪力墙的破坏形态为压弯破坏及底部混凝土压溃而丧失竖向承载能力;钢管混凝土剪力墙的开裂水平力、名义屈服水平力、正截面受弯承载力和变形能力均比相同参数的钢筋混凝土剪力墙大;配置双钢管剪力墙的变形能力大于配置单钢管的剪力墙,约束边缘构件为端柱的剪力墙的变形能力大于约束边缘构件为暗柱的剪力墙;正截面受弯承载力试验值大于计算值。根据试验结果,提出了钢管混凝土剪力墙的设计建议。图9表7参13  相似文献   

17.
为研究正交胶合木(CLT)-混凝土螺栓连接的力学性能,对12个顺纹连接试件和12个横纹连接试件进行了单调加载和低周往复加载试验,总结了连接典型的破坏模式,得到了连接的初始刚度、承载力及延性系数等力学性能;利用ABAQUS软件对连接进行非线性参数分析,研究螺栓直径、螺栓强度等级及CLT层板厚度等参数对连接力学性能的影响。结果表明:连接的破坏模式与厚径比(CLT厚度与螺栓直径之比)相关,当厚径比不大于6.56时,主要发生单塑性铰屈服、木材销槽承压及局部承压破坏;螺栓直径一定时,增加CLT层板厚度可有效提高连接承载力;当厚径比大于6.56时,主要发生螺栓双塑性铰屈服与剪断破坏;增加层板厚度对连接初始刚度、承载力和破坏模式无明显影响。针对螺栓屈服破坏模式,增大螺栓直径可提高连接的初始刚度与承载力;提高螺栓强度等级对初始刚度影响较小,但可提高连接承载力。  相似文献   

18.
目前国内外对钢-玻璃组合梁结构的受力模式及承载力研究不足,对5个钢-玻璃组合梁试件进行了平面内受力性能试验,并基于多线性和线性材料本构模型进行了有限元分析。研究了采用钢化夹层(胶)玻璃腹板和单片钢化玻璃腹板组合梁的剪压破坏模式及纯弯曲破坏模式,两种破坏模式的区别在于纯弯曲破坏始于梁底弯矩最大部位,而剪压破坏在局部受压及剪跨区域发生。采用我国JGJ 102—2003中关于平面内玻璃肋受弯计算公式分析了组合梁承载力,基于塑性铰线方法提出了该类组合梁承载力的理论计算公式。研究结果表明:剪压破坏时钢化夹层(胶)玻璃腹板随着荷载增大而呈现明显的界面孔隙,相比同厚度的单片钢化玻璃腹板,夹层(胶)玻璃腹板能提高组合梁的弯曲变形能力。增加腹板玻璃厚度和胶结强度均可提高组合梁的承载力,且前者的贡献更为明显,对于后者,剪压破坏和纯弯曲破坏分别取决于结构胶的压缩模量和剪切模量。考虑了胶结部分受拉刚度贡献的有效截面系数能更好预测组合梁的纯弯曲破坏承载力,而提出基于塑性铰线机制的计算方法能更好预测组合梁的剪压破坏承载力。  相似文献   

19.
为了研究组合梁在复杂应力状态下抗剪连接件的力学性能,进行了两个布置有不同类型的抗剪连接件的小规模模型测试。这些模型的设计都是基于广州的一座组合梁桥。详细地研究了在相同边界条件下的刚性抗剪连接件模型和弹性抗剪连接件模型的钢筋混凝土交界面的相对滑移的比较分析。在三种不同类型的荷载形式作用下的两种抗剪连接件的反应也进行了比较。模型测试结果表明混凝土的极限承载能力是决定钢筋混凝土交界面上的相对滑移的关键因素而且刚性抗剪连接件和弹性抗剪连接件的区别是非常明显的。这份报告对于组合梁的抗剪连接件的未来研究和设计很有参考价值。  相似文献   

20.
针对带窗洞复合墙板受弯与受压承载力不足的问题,提出了一种带框复合墙板,即通过在复合墙板内设置暗梁、暗柱来提高其承载力。对5块足尺的带窗洞复合墙板进行四点弯曲试验和偏心受压试验,考察其破坏模态和承载能力。试验结果表明,复合墙板的抗弯刚度较高,受弯荷载满足由美国ASCE/SEI 7-05规范计算得到的关岛风荷载设计值要求;在四点弯曲荷载和偏心受压荷载作用下,复合墙板能实现完全组合作用,两侧混凝土面层变形协调,符合“平截面假定”;复合墙板在四点弯曲荷载下发生延性破坏。分别按美国ACI 318M-05《混凝土结构设计规范和注释》和中国GB 50010—2010《混凝土结构设计规范》对复合墙板的受弯承载力进行了计算,计算值与试验值误差最大不超过16%,并且利用两种规范公式计算得到的承载力均较为保守。  相似文献   