排序方式: 共有3条查询结果,搜索用时 15 毫秒
1
1.
Ighalo Joshua O. Iwuchukwu Felicitas U. Eyankware Oghenegare E. Iwuozor Kingsley O. Olotu Kristinoba Bright Omoregie Cyril Igwegbe Chinenye Adaobi 《Clean Technologies and Environmental Policy》2022,24(8):2349-2363
Clean Technologies and Environmental Policy - To assuage global consumer demand for energy, there is a need for increased biofuel production. Flash pyrolysis is an important technique for biomass... 相似文献
2.
Ifeyinwa J. Iwuchukwu Ernest IwuchukwuRosemary Le Caitlin PaquetRapinder Sawhney Barry Bruce Paul Frymier 《International Journal of Hydrogen Energy》2011,36(18):11684-11692
Light-dependent hydrogen production by platinized Photosystem I isolated from the cyanobacterium Thermosynechococcus elongatus BP-1 was optimized using response surface methodology (RSM). The process parameters studied included temperature, light intensity and wavelength, and platinum salt concentration. Application of RSM generated a model that agrees well with the data for H2 yield (R2 = 0.99 and p < 0.001). Significant effects on the total H2 yield were seen when the platinum salt concentration and temperature were varied during platinization. However, light intensity during platinization had a minimal effect on the total H2 yield within the region studied. The values of the parameters used during the platinization that optimized the production of H2 were light intensity of 240 μE m−2 s−1, platinum salt concentration of 636 μM and temperature of 31 °C. A subsequent validation experiment at the predicted conditions for optimal process yield gave the maximum H2 yield measured in the study, which was 8.02 μmol H2 per mg chlorophyll. 相似文献
3.
Min Hea KimIfeyinwa J. Iwuchukwu Ying WangDonglee Shin John SanseverinoPaul Frymier 《Journal of power sources》2011,196(4):1909-1914
The performance of a dual anode-chambered microbial fuel cell (MFC) inoculated with Shewanella oneidesis MR-1 was evaluated. This reactor was constructed by incorporating two anode chambers flanking a shared air cathode chamber in an electrically parallel, geometrically stacked arrangement. The device was shown to have the same maximum power density (approximately 24 W m−3, normalized by the anode volume) as a single anode-, single cathode-chambered MFC. The dual anode-chambered unit generated a maximum current of 3.66 mA (at 50 Ω), twice the value of 1.69 mA (at 100 Ω) for the single anode-chambered device at approximately the same volumetric current density. Increasing the Pt-coated cathode surface area by 100% (12 to 24 cm2) had no significant effect on the power generation of the dual anode-chambered MFC, indicating that the performance of the device was limited by the anode. The medium recirculation rate and substrate concentration in the anode were varied to determine their effect on the anode-limited power density. At the highest recirculation rate, 5 ml min−1, the power density was about 25% higher than at the lowest recirculation rate, 1 ml min−1. The dependence of the power density on the lactate concentration showed saturation kinetics with a half-saturation constant Ks on the order of 4.4 mM. 相似文献
1