首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The effect of ultrasound on pool boiling heat transfer to mixtures of the refrigerants R23 and R134a has been investigated in a wide range of heat flux and saturation pressure. The enhancement of the heat transfer coefficient, which can be achieved by ultrasound, is much more pronounced for mixtures than for pure substances. It is, however, limited to rather small heat fluxes ( ). Especially remarkable is the fact, that the maximum influence of ultrasound on the heat transfer coefficient of the mixtures occurs at medium saturation pressures (p/pc ≈ 0.2); the effect is markedly less for higher and for lower saturation pressures. Obviously, the improvement of the heat transfer to mixtures is mainly caused by a decrease of the local saturation temperature near the heating wall, due to a better mixing in the liquid boundary. This explanation is supported by evaluating important parameters of bubble formation from high-speed photographs of the heating surface. It is further noticeable, that the well known hysteresis effect at the beginning of pool boiling is reduced to a great extent by exposure to ultrasound.  相似文献   

2.
Influence of the heat flux in mixture boiling: experiments and correlations   总被引:3,自引:0,他引:3  
Heat transfer at nucleate pool boiling of the binary and ternary refrigerant mixtures R404A, R407C and R507 at the outside of a horizontal tube with emery ground surface has been investigated in a wide range of pressures and heat fluxes. Together with experimental data of Bednar and Bier for wide boiling ethane/n-butane mixtures, the results of these comparatively narrow boiling mixtures are used to investigate the influence of heat flux q on the heat transfer coefficient as predicted by various correlations for nucleate boiling of mixtures. At comparatively high saturation pressures with experimental -values markedly smaller than the molar average of the pure components, the ,q-relationships predicted differ significantly from the experimental, particularly for wide boiling mixtures.  相似文献   

3.
实验研究了填充泡沫金属的圆管内制冷剂与润滑油混合物流动沸腾换热特性。实验对象为两根分别填充5PPI、90%孔隙率与10PPI、90%孔隙率泡沫铜的圆管,以及相同管径的光管。实验工况为蒸发压力995kPa,质流密度为10~30 kg/(m2.s),热流密度为3.1~9.3kW/m2,入口干度0.175~0.775,油浓度为0~5%。实验结果表明:纯制冷剂工况下,泡沫金属的存在强化流动沸腾换热,换热系数最多提高185%;含油工况下,泡沫金属强化换热的效果弱化;相同工况下,更小的孔径可以提高流动沸腾换热系数,相比5PPI泡沫金属的实验数据,10PPI的泡沫金属可以使换热系数最多提高0.6倍。基于流型建立了填充泡沫金属的圆管内制冷剂与润滑油流动沸腾换热系数的预测模型,预测模型与98%的实验数据误差在±30%以内。  相似文献   

4.
This paper describes the influence of a low viscosity polyolester based lubricating oil on the pool boiling heat transfer of the refrigerant R507. The pool boiling heat transfer coefficients for this refrigerant–oil mixture are measured on a smooth tube and on an enhanced tube. The investigation is made for oil mass fractions up to 10% and for saturation temperatures between −28.6°C and +20.1°C. For the smooth tube the heat transfer increases for increasing oil mass fractions up to 3% at lower saturation temperatures. At higher saturation temperatures the heat transfer decreases for increasing oil mass fractions for both tubes. For oil mass fractions greater than 1% at the higher saturation temperatures a range of decreasing heat transfer coefficient is found for increasing heat flux. The effect is caused by the different miscibility of the oil and the components of the refrigerant mixture.  相似文献   

5.
Heat transfer coefficients for nucleate boiling of methane, ethane, ethylene, argon and carbon dioxide were determined using an apparatus for the precise investigation of pool boiling heat transfer in the low temperature range. The apparatus used a horizontal cylinder as the heating element. The influence of the thermophysical properties of the boiling liquid was established by comparing the absolute values of the heat transfer coefficients in a normalized boiling state, i.e. a saturation pressure equal to 10% of the critical pressure and a heat flux density equal to 2 × 104 W m−2. By including the results for a number of higher boiling liquids, which were investigated previously under similar experimental conditions, and using literature data for three very low boiling liquids, an empirical correlation is established which allows an approximate prediction of the absolute value of the heat transfer coefficient at nucleate boiling for substances of different molecular structure.  相似文献   

6.
In a flooded evaporator of an ammonia vapor-compression refrigeration system, boiling commonly takes place with ammonia mixed with compressor lubricant and subjected to a vapor quality at the inlet of the evaporator. In the present study, flooded boiling tests of ammonia on an enhanced tube under simultaneous influence of a miscible lubricant and inlet quality were conducted. The results suggest that the boiling heat transfer coefficient increases with both saturation temperature and heat flux. The coefficient slightly increases or does not significantly vary with the inlet quality. The coefficient in general is decreased by adding lubricant to the refrigerant, but the coefficient does not necessarily decrease as the lubricant concentration increases. The lubricant effect is generally more significant than the inlet quality effect. A correlation was developed based on the present data for flooded boiling of lubricant/ammonia mixture on an enhanced horizontal tube under the influence of inlet quality.  相似文献   

7.
对R134a在水平直管和螺旋管内的沸腾换热特性进行了实验研究.在三个不同的蒸发温度(5℃、10℃和20℃),工质R134a的质量流量范围为100~400kg/(m~2·s)和干度范围为0.1~0.8的条件下,实验得到了R134a在水平直管和螺旋管内的沸腾换热系数随其质量流量和干度的变化关系,将水平直管和螺旋管内的沸腾换热特性数据进行了比较,结果显示,在实验条件下,卧式螺旋管的传热系数比直管的平均增加13.7%.  相似文献   

8.
This study investigated the effect of tube diameter on flow boiling characteristics of refrigerant R32 in horizontal small-diameter tubes with 1.0, 2.2, and 3.5 mm inner diameters. The boiling heat transfer coefficient and pressure drop were measured at 15 °C saturation temperature. The effects of mass velocity, heat flux, quality, and tube diameter were clarified. The flow pattern of R32 for adiabatic two-phase flow in a horizontal glass tube with an inner diameter of 3.5 mm at saturation temperature of 15 °C was investigated. Flow patterns such as plug, wavy, churn, and annular flows were observed. The heat transfer mechanisms of forced convection and nucleate boiling were similar to those in conventional-diameter tubes. In addition, evaporation heat transfer through a thin liquid film in the plug flow region for low quality, mass velocity, and heat flux was observed. The heat transfer coefficient increased with decreasing tube diameter under the same experimental condition. The fictional pressure drop increased with increasing mass velocity and quality and decreasing tube diameter. The experimental values of the heat transfer coefficient and frictional pressure drop were compared with the values calculated by the empirical correlations in the open literature.  相似文献   

9.
Carbon dioxide is again becoming an important refrigerant. While the thermophysical properties are well known there is a lack of data on its heat transfer characteristics.

In this study, heat transfer coefficients for nucleate boiling of carbon dioxide are determined using a standard apparatus for the investigation of pool boiling based on a set-up from Karlsruhe [D. Gorenflo, J. Goetz, K. Bier. Vorschlag für eine Standard-Apparatur zur Messung des Wärmeübergangs beim Blasensieden. Wärme-und Stoffübertragung 16 (1982), 69–78; J. Goetz, Entwicklung und Erprobung einer Normapparatur zur Messung des Wärmeübergangs beim Blasensieden. Dissertation Universität Karlsruhe (1980).] and built at our institute. Electrically heated horizontal cylinders with an outer diameter of 16 mm and a length of 100 mm are used as heating elements. Measurements with constant heat flux are performed for different wall materials and surface roughnesses. The heat transfer is investigated within the pressure range of 0.53≤ p ≤1.43 MPa (0.072≤ p/pc ≤0.190) and a temperature range of −56≤ t ≤−30 °C, respectively. Heat fluxes of up to 80,000 W m−2 are applied.

The influences of wall material and roughness on the heat transfer coefficient are evaluated separately. The obtained coefficients are compared to generally accepted correlations and to experimental results of other authors, who used similar configurations with copper tubes and carbon dioxide. These are the only previous experimental data, which could be found. Results for copper, stainless steel and aluminium as wall materials are presented.  相似文献   


10.
Although application of carbon dioxide as working fluid in many fields of refrigeration technology has been recommended very often in the recent past, the data on nucleate boiling heat transfer of carbon dioxide in free convection are very scarce in the open literature and new investigations are almost entirely focussed on forced convective flow boiling. In the interpretation of the respective results, heat transfer to carbon dioxide is often characterized as being superior to other refrigerants due to the outstandingly favourable thermophysical properties of carbon dioxide for boiling heat transfer. Different from this view, the discussion of recent results on pool boiling heat transfer of carbon dioxide in this review demonstrates that the high heat transfer coefficients measured for carbon dioxide in comparison to hydrocarbon or halocarbon refrigerants are mainly due to the fact that application of carbon dioxide is mostly envisaged for conditions where reduced saturation pressure p*=ps/pc (pc, critical pressure) is higher than for common refrigerants.

In the first part of the review, the three main influences—by heat flux, saturation pressure and fluid properties—on pool boiling of carbon dioxide are discussed using recent measurements for CO2 by Kotthoff et al. [S. Kotthoff, U. Chandra, D. Gorenflo, A. Luke, New measurements of pool boiling heat transfer for carbon dioxide in a wide temperature range, Proceedings of the Sixth IIR-Gustav Lorentzen Conference, Glasgow, 2004 [paper 2/A/3.30]; see also S. Kotthoff, U. Chandra, D. Gorenflo, Neue Messungen zum Behältersieden von Kohlendioxid in einem grösseren Temperaturbereich, DKV-Tagungsbericht 22 (2004) [Bd.II. 1] 233–256 and other organic substances (Gorenflo et al.) [D. Gorenflo, S. Kotthoff, U. Chandra, New measurements of pool boiling heat transfer with hydrocarbons and other organics for update of VDI—Heat Atlas calculation method, Proceedings of the Sixth IIR-Gustav Lorentzen Conference, Glasgow, 2004 [paper 1/C/1.00]; Kotthoff and Gorenflo, [S. Kotthoff, D. Gorenflo, Influence of the fluid on pool boiling heat transfer of refrigerants and other organic substances, Proceedings of the IIR-Commission B1 Conference, Vicenza, 2005 [paper #TP-98]. In the second part, a comparison is given with the few former data available and with new results of Loebl and Kraus [S. Loebl, W.E. Kraus, Pool boiling heat transfer of carbon dioxide on a horizontal tube, Proceedings of the Sixth IIR-Gustav Lorentzen Conference, Glasgow, 2004 [paper 1/A/1.20]; S. Loebl, W.E. Kraus, Zum Wärmeübergang bei der Verdampfung von Kohlendioxid am horizontalen Rohr, DKV-Tagungsbericht 22 (2004) [Bd.II.1] 219–232 on the influence of the heating wall (material and surface roughness). Finally, analogies between nucleate pool boiling and new flow boiling data are shown for those domains of flow boiling in which nucleation provides the dominant contribution to heat transfer and convective effects are of secondary importance.  相似文献   


11.
Heat transfer from five horizontal copper plates with different surface finish to boiling refrigerants R11 (CFCI3) and R115 (C2F5Cl) was measured at saturation pressures between 0.4 and 91% of the critical pressure. Although the relative pressure dependence of the heat transfer coefficient α is similar for the plates with different surface treatment, a detailed comparison of the experimental results shows that the influence of the different surface conditions achieved by mechanical and chemical treatment on the absolute value of α cannot be correlated by one of the roughness parameters used in the literature, within the whole range of pressures investigated.  相似文献   

12.
Experimental values on nucleate and film boiling of carbon dioxide on polished and porous cylindrical surfaces under conditions of saturation at reduced pressures, P/Pcrit=0.93 and 0.97 are discussed. A considerable increase of the maximal, minimal specific heat fluxes and maximal heat transfer coefficient was observed on a horizontal tube with thin porous coating.  相似文献   

13.
Heat transfer from five horizontal copper plates with different surface finish to boiling refrigerants R11 (CFCI3) and R115 (C2F5Cl) was measured at saturation pressures between 0.4 and 91% of the critical pressure. Although the relative pressure dependence of the heat transfer coefficient α is similar for the plates with different surface treatment, a detailed comparison of the experimental results shows that the influence of the different surface conditions achieved by mechanical and chemical treatment on the absolute value of α cannot be correlated by one of the roughness parameters used in the literature, within the whole range of pressures investigated.  相似文献   

14.
The experimental and theoretical researches have been carried out to get the flow boiling heat transfer characteristics of carbon dioxide (CO2 or R744) as a refrigerant in horizontal mini-channel. Based on infrared thermal imaging tests and experimental studies on heat transfer coefficients, the heat transfer coefficients and dryout characteristics of CO2 are analyzed qualitatively and quantitatively in following conditions: Heat flux: 2~35 kW m-2, Mass flux: 50~1350 kg m-2 s-1, saturation temperature: −10~15 °C, mini-channel inner diameter: 1 mm and 2 mm. Primary conclusions can be drawn from the results of the experiments: The increase of heat flux enhances the nucleate boiling heat transfer of the refrigerant inside mini-channel, which leads to the remarkable increase of heat transfer coefficient. But it speeds up the process of dryout. It also has a certain influence on vapor qualities of dryout at both the starting and the ending stage. The effect of mass flux on heat transfer enhancement depends on the dominant heat transfer mode in the tube. With the increase of mass flow rate, the vapor quality at the start of dryout has a decreasing trend. But the heat transfer coefficient increases at the end of dryout process or even after dryout process; the heat transfer coefficient does not vary monotonically with the saturation temperature: when the saturation temperature is high and even close to CO2's critical temperature, the heat transfer coefficient increases with the increase of saturation temperature; when the saturation temperature is low, the heat transfer coefficient increases with the decrease of saturation temperature. Besides, during the heat transfer process, the dryout vapor quality falls monotonically with the increase of saturation temperature. It is reasonable to conclude that dryout characteristics have significant influence on heat transfer coefficient. Fang correlation that predicts the heat transfer coefficient of CO2 is in good agreement with the experimental data, which has a mean absolute deviation of 15.7%, and predicts 71.98% of the entire database within ±20% and 86.84% of the entire database within ±30%.  相似文献   

15.
The flow and heat transfer characteristics of binary refrigerant mixtures in a heated horizontal tube were investigated numerically. The pressure drop, temperature profile, and heat transfer coefficient for non-azeotropic and near-azeotropic mixtures of different bulk compositions were obtained. It is found that the non-linear physical properties of the mixtures strongly affect the pressure drop characteristics. Both the fluid properties and mass transfer resistance are responsible for the heat transfer characteristics. The mass transfer resistance has a more significant influence on the nucleate boiling than the convective evaporation for non-azeotropic mixtures, while the resistance can be neglected for near-azeotropic mixtures.  相似文献   

16.
应用FLUENT软件对制冷剂R134a在光管和横纹槽管水平管外沸腾传热进行三维数值模拟,得到其饱和泡状沸腾过程中体积含气率的分布规律,并比较它们的换热系数。结果表明横纹槽管外侧能够很好地强化沸腾传热。此外,还通过改变边界条件分析质量流量、热流密度的变化对横纹槽管管外沸腾换热系数的影响。最后应用场协同理论,从局部换热角度分析其强化机制。研究表明,横纹槽管水平管外沸腾换热得到强化的原因是其凹槽前后的速度场与温度梯度场之间夹角较小,协同程度更好。  相似文献   

17.
An updated version of the Kattan–Thome–Favrat flow pattern based, flow boiling heat transfer model for horizontal tubes has been developed specifically for CO2. Because CO2 has a low critical temperature and hence high evaporating pressures compared to our previous database, it was found necessary to first correct the nucleate pool boiling correlation to better describe CO2 at high reduced pressures and secondly to include a boiling suppression factor on the nucleate boiling heat transfer coefficient to capture the trends in the flow boiling data. The new method predicts 73% of the CO2 database (404 data points) to within ±20% and 86% to within ±30% over the vapor quality range of 2–91%. The database covers five tube diameters from 0.79 to 10.06 mm, mass velocities from 85 to 1440 kg m−2 s−1, heat fluxes from 5 to 36 kW m−2, saturation temperatures from −25 °C to +25 °C and saturation pressures from 1.7 to 6.4 MPa (reduced pressures up to 0.87).  相似文献   

18.
Nucleate pool boiling heat transfer characteristics of refrigerant/oil mixture on metal foam covers were experimentally investigated. The refrigerant is R113, and the oil is VG68. The copper foams, having ppi (pores per inch) of 10 and 20, porosity from 90% to 98%, and thickness of 5 mm, are selected in this study. Experimental conditions include a saturation pressure of 101 kPa, oil concentrations from 0 to 5%, and heat fluxes from 0 to 80 kW m−2. The experimental results indicate that the nucleate pool boiling heat transfer coefficient on copper foam covers is larger than that on flat heated surface by a maximum of 160% under the present experimental conditions; the presence of oil deteriorates the nucleate pool boiling heat transfer on copper foam covers by a maximum of 15% under the present experimental conditions, and the deterioration of oil on nucleate pool boiling heat transfer on copper foam covers is lower than that on a flat heated surface. A correlation for predicting the nucleate pool boiling heat transfer coefficient of refrigerant/oil mixture on copper foam cover is developed, and it agrees with 95% of the experimental data within a deviation of ±20%.  相似文献   

19.
Shell-side heat transfer coefficients of individual tubes for ammonia/lubricant mixture boiling on a 3 × 5 enhanced tube bundle were measured, enabling a detailed study of tube bundle effect under the influences of inlet quality, concentration of miscible lubricant (co-polymer of polyalkylene glycol, PAG), saturation temperature, and heat flux. Tests were conducted in the range of heat flux from 3.2 to 32.0 kW/m2, simulated inlet quality from 0.0 to 0.4, saturation temperature from −13.2 to +7.2 °C, and lubricant concentration from 0 to 10%. The data show that bundle effect is more significant at a higher saturation temperature. Most of the data in the bottom row are lower than the single-tube heat transfer coefficient data at a low saturation temperature. Lubricant renders the heat transfer coefficient lower in lower rows and higher in higher rows, therefore a larger range of data variation.  相似文献   

20.
Heat transfer and pressure drop characteristics of CO2 flow boiling in mini tube with micro fins of zero helix angle were experimentally investigated. The working conditions cover mass flux from 100 to 600 kg m−2 s−1, heat flux from 1.67 to 8.33 kW m−2, vapor quality from 0 to 0.9 and saturation temperature from 1 to 15 °C. The results show that the heat transfer coefficient increases with increasing vapor quality, but sharply decreases at vapor quality around 0.2~0.4 under most conditions, and the dryout vapor quality decreases with the increasing heat flux and saturation temperature. Pressure drop increases with increasing mass flux and heat flux, or decreasing saturation temperature, and mass flux is the major influence factors. The enhancement ratio of heat transfer coefficient is higher than that of pressure drop, which shows potentials of using such kind tubes to enhance the overall heat transfer performance. A heat transfer coefficient correlation and a pressure drop correlation for 0° helix angle micro-fin tube were developed, and they agree well with the experimental data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏