首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A new method for improving low-concentration sample recovery and reducing sample preparation steps in matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) is presented. In the conventional approach, samples are typically desalted and/or concentrated with various techniques and deposited on the MALDI target as small droplets. In this work, we describe a new approach in which an elastomeric device is reversibly sealed on the MALDI target to form a multi-well plate with the MALDI target as the base of the plate. The new format allows a larger volume (5-200 microL) of samples to be deposited on each spot and a series of sample handling processes, including desalting and concentrating, to be performed directly on the MALDI target. Several advantages have been observed: (i) multiple sample transferring steps are avoided; (ii) recovery of low-concentration peptides during sample preparation is improved using a novel desalting method that utilizes the hydrophobic surface of the elastomeric device; and (iii) sequence coverage of the peptide mass fingerprinting map is improved using a novel method in which proteins are immobilized on the hydrophobic surface of the elastomeric device for in-well trypsin digestion, followed by desalting and concentrating the digestion products in the same well.  相似文献   

2.
The separation of peptide mixtures from proteolytic cleavage is often necessary prior to mass spectrometry (MS) to enhance sensitivity and peptide mapping coverage. When buffers, salts, and other higher abundance peptides/contaminants are present, competition for charge during the electrospray ionization and matrix-assisted laser desorption/ionization (MALDI) processes can lead to ion suppression for the targeted analyte(s). In this note, a simple reversed-phase microcolumn sample separation and deposition device (Sep-Dep) is described. The use of this device improves or renders possible the analysis of complex or contaminated peptide mixtures by MALDI-MS. The method is simple and inexpensive and utilizes single-use low-cost Geloader-type columns packed with reversed-phase material. The device described utilizes an open column, allowing for a gradient or narrow-step gradient to be applied by any solvent delivery system or manually with a pipet. A key feature of the device is a deposition chamber that can be custom-built to hold any MALDI target. The Sep-Dep device is attached directly to an in-house vacuum line and draws solvent from the open-ended LC column. The elution of separated peptides is performed directly onto a target that has been treated with a hydrophobic barrier. This barrier effectively isolates fractions and improves the quality and morphology of the matrix crystals. The method produces efficient separations of proteolytic peptides, significantly reducing signal suppression effects in MALDI.  相似文献   

3.
The use of histidine as a protein digestion buffer followed by isoelectric trapping separations using "membrane separated wells for isoelectric focusing and trapping" (MSWIFT) and mass spectrometry (MS) analysis is described. Tryptic digestion of bovine serum albumin (BSA) performed in histidine buffered solutions yields similar amino acid sequence coverage values to those obtained using ammonium bicarbonate buffer. Time course studies suggest that histidine buffers provide faster migration of peptides from the loading compartment compared to digestions prepared in ammonium bicarbonate due to differences in conductivities of the two buffers. In addition, this sample preparation method and MSWIFT separations have been coupled with capillary electrophoresis (CE) and matrix-assisted laser desorption ionization-mass spectrometry (MALDI-MS) as an alternative separation approach for proteomic studies. Tryptic peptides of ribosomal proteins in histidine are fractionated using MSWIFT followed by CE-MALDI-MS, which further illustrates the ability to couple fractions from a pI based separation device to CE-MS. Specifically, two-dimensional CE-MS plots provide a direct correlation between the numbers of basic residues within the peptide sequence displayed in charge-state trend lines. Combining MSWIFT and CE-MS provides added information regarding peptide sequence, specifically pI and in-solution charge state. Post-translational modifications can also be identified using this method.  相似文献   

4.
A new multichannel deposition system was developed for off-line liquid chromatography/matrix-assisted laser desorption/ionization mass spectrometry (LC/MALDI-MS). This system employs a pulsed electric field to transfer the eluents from multiple parallel columns directly onto MALDI targets without the column outlets touching the target surface. The deposition device performs well with a wide variety of solvents that have different viscosities, vapor pressures, polarities, and ionic strengths. Surface-modified targets were used to facilitate concentration and precise positioning of samples, allowing for efficient automation of high-throughput MALDI analysis. The operational properties of this system allow the user to prepare samples using MALDI matrixes whose properties range from hydrophilic to hydrophobic. The latter, exemplified by alpha-cyano-4-hydroxycinnamic acid, were typically processed with a multistep deposition method consisting of precoating of individual spots on the target plate, sample deposition, and sample recrystallization steps. Using this method, 50 amol of angiotensin II was detected reproducibly with high signal-to-noise ratio after LC separation. Experimental results show that there is no significant decrease in chromatographic resolution using this device. To assess the behavior of the apparatus for complex mixtures, 5 microg of a tryptic digest of the cytosolic proteins of yeast was analyzed by LC/MALDI-MS and more than 13,500 unique analytes were detected in a single LC/MS analysis.  相似文献   

5.
Young JB  Li L 《Analytical chemistry》2007,79(15):5927-5934
An automated off-line liquid chromatography-matrix-assisted laser desorption ionization (LC-MALDI) interface capable of coupling both capillary and microbore LC separations with MALDI mass spectrometry (MS) and tandem mass spectrometry (MS/MS) has been developed. The interface is a combination of two concepts: analyte concentration from heated hanging droplets and impulse-driven droplet deposition of LC fractions onto a MALDI sample plate. At room temperature the interface allows the coupling of capillary LC separations (i.e., flow rate of <5 microL/min) with MALDI MS. With heating, it can be used to combine microbore LC operated at a relatively high flow rate of up to 50 microL/min with MALDI MS. The collected fractions can be analyzed by MALDI MS and MS/MS instruments, such as time-of-flight (TOF) and quadrupole-TOF MS. Performance of the interface was examined using several peptide and protein standards. It was shown that, using MALDI-TOF MS, [GLU1]-fibrinopeptide B could be detected with a total injection amount of 5 fmol to microbore LC. Chromatographic performance was also monitored. A peak width of 12 s at half-height for [GLU1]-fibrinopeptide B showed no evidence of band broadening due to the interface. The ability of the interface to mitigate ion suppression was studied using a mixture of 100 fmol of [GLU1]-fibrinopeptide B and 10 pmol of cytochrome c tryptic digest. Although fully suppressed under direct MALDI conditions, LC-MALDI analysis was able to detect the 100 fmol peptide with 10 s fraction collection. Finally, the ability to inject relatively large sample amounts to improve detectability of low-abundance peptides was illustrated in the analysis of phosphopeptides from alpha-casein tryptic digests. A digest loaded on column to 2.4 microg and analyzed by LC-MALDI MS/MS resulted in 82% sequence coverage and detection of all nine phosphoserine residues. It is concluded that, being able to handle both high- and low-flow LC separations, the impulse-driven heated-droplet interface provides the flexibility to carry out MALDI analysis of peptides and proteins depending on the information sought after, analysis speed, and sample size.  相似文献   

6.
This study demonstrates the ability to perform sensitive proteome analysis on the limited protein quantities available through tissue microdissection. Capillary isoelectric focusing combined with nano-reversed-phase liquid chromatography in an automated and integrated platform not only provides systematic resolution of complex peptide mixtures based on their differences in isoelectric point and hydrophobicity but also eliminates peptide loss and analyte dilution. In comparison with strong cation exchange chromatography, the significant advantages of electrokinetic focusing-based separations include high resolving power, high concentration and narrow analyte bands, and effective usage of electrospray ionization-tandem MS toward peptide identifications. Through the use of capillary isoelectric focusing-based multidimensional peptide separations, a total of 6866 fully tryptic peptides were detected, leading to the identification of 1820 distinct proteins. Each distinct protein was identified by at least one distinct peptide sequence. These high mass accuracy and high-confidence identifications were generated from three proteome runs of a single glioblastoma multiforme tissue sample, each run consuming only 10 microg of total protein, an amount corresponding to 20,000 selectively isolated cells. Instead of performing multiple runs of multidimensional separations, the overall peak capacity can be greatly enhanced for mining deeper into tissue proteomics by increasing the number of CIEF fractions without an accompanying increase in sample consumption.  相似文献   

7.
A method is developed to integrate a protein separation by monolithic capillary reversed-phase high-performance liquid chromatography to on-probe tryptic digestion for subsequent analyses by MALDI-TOF MS and MALDI-TOF/TOF MS. The method provides a means of directly interfacing separations to MALDI-MS, reducing the amount of time required for traditional procedures involving in-solution enzymatic digestion and sample cleanup prior to MALDI-MS analysis. When used with pI-based fractionation as a first dimension, it provides a means of analyzing complex mixtures of proteins with minimal sample handling and cleanup. The use of monolithic capillary columns sufficiently resolved intact proteins so that peptide mass fingerprinting analysis by MALDI-TOF MS resulted in the identification of close to 40 unique proteins from 120 ng of sample obtained from a prefractionated MCF10 cell line at pH 6.34, where the identifications of several of these proteins were also confirmed by intact MW and tandem mass spectrometric analysis. The reproducibility of this method has been demonstrated to be sufficient for the purpose of protein identifications. Experimental values of protein intact MW are obtained and compared to that expected for each protein identified.  相似文献   

8.
Automated analyses in MALDI MS are complicated by the uneven distribution of analyte over the sample spot, resulting in areas of analyte localization, or "sweet spots". Hence, the ability to concentrate and localize samples is advantageous, especially for automated studies involving low concentrations of analyte. A method for rapidly creating a removable and affordable hydrophobic surface that is free from memory effect is presented. The potential for such compounds to serve as a practical coating for MALDI targets is examined. An example compound with a complete methodology is shown to increase sample homogeneity, peak intensity, and resolution when used for peptide mixtures with CHCA and DHB.  相似文献   

9.
Wang J  Chen R  Ma M  Li L 《Analytical chemistry》2008,80(2):491-500
Recently developed sample preparation techniques employing hydrophobic sample support have improved the detection sensitivity and mass spectral quality of matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). These methods concentrate the samples on target by minimizing the sample area via the solvent repellent effect of the target surface. In the current study, we employed the use of paraffin wax film (Parafilm M) for improved MALDI MS analysis of low-abundance peptide mixtures, including neuronal tissue releasate and protein tryptic digests. This thin film was found to strongly repel polar solvents including water, methanol, and acetonitrile, which enabled the application of a wide range of sample preparation protocols that involved the use of various organic solvents. A "nanoliter-volume deposition" technique employing a capillary column has been used to produce tiny ( approximately 400 microm) matrix spots of 2,5-dihydroxybenzoic acid on the film. By systematically optimizing the sample volume, solvent composition, and film treatment, the Parafilm M substrate in combination with the nanoliter-volume matrix deposition method allowed dilute sample to be concentrated on the film for MALDI MS analysis. Peptide mixtures with nanomolar concentrations have been detected by MALDI time-of-flight and MALDI Fourier transform ion cyclotron resonance mass spectrometers. Overall, the use of Parafilm M enabled improved sensitivity and spectral quality for the analysis of complex peptide mixtures.  相似文献   

10.
To fully automate the sample introduction step for nanoscale microcapillary liquid chromatography-tandem mass spectrometry (LC-MS/MS) analyses, 75 microm i.d. x 14 cm capillary columns were interfaced with a commercial autosampler instrument using a novel procedure which allowed dilute peptide samples to be transferred from the AS loop injector to the nanoscale column at flow rates up to 5 microL min(-1). On-column enrichment and desalting was demonstrated for large sample volumes (>40 microL) by constructing a vent 2 cm after the entrance to the packed bed of 5-microm ODS-AQ modified silica. Salts and nonretained solutes were removed via the vent, which allowed for column washing independent of the continuation of the bed into the electrospray source. Separations of test peptide mixtures demonstrated 50-nL elution peak volumes with low- to subfemtomole detection levels. In addition, a highly complex peptide mixture (outer membrane preparation from Psuedemonas aeruginosa) was efficiently separated with more than 100 proteins identified from a single reversed-phase LC-MS/MS analysis. Finally, the vented column (V-column) was utilized for on-line separations in a multidimensional chromatography/tandem MS experiment where large numbers of strong cation exchange chromatography fractions from a trypsinized yeast lysate were desalted, concentrated, and analyzed in a completely automated fashion. The procedures for constructing and using a V-column require minimal changes in current methods and equipment for nano-LC-MS analyses using columns of 100-microm diameter and smaller.  相似文献   

11.
High-efficiency capillary isoelectric focusing of peptides   总被引:6,自引:0,他引:6  
Several approaches are presently being developed for global proteome characterization that are based upon the analysis of polypeptide mixtures resulting from digestion of (often complex) mixtures of proteins. Improved methods for peptide analysis are needed that provide for sample concentration, higher resolution separations, and direct compatibility with mass spectrometry. In this work, methods for the high-efficiency capillary isoelectric focusing (CIEF) separation of peptides have been developed that provide for simultaneous sample concentration and separation according to peptide isoelectric point. Under typical nondenaturing CIEF conditions, peptides are concentrated approximately 500-fold, and peptides present at < 1 ng/ microL were detectable using conventional UV detection. CIEF separations of peptides provided much faster measurements of isoelectric points compared with conventional isoelectric focusing in gels. Very small differences in peptide isoelectric points (deltapI approximately 0.01) could be resolved, High-efficiency CIEF separations for complex peptide mixtures from tryptic digestion of yeast cytosol fractions were obtained and showed significant improvement over those obtained using capillary zone electrophoresis and packed capillary reversed-phase liquid chromatography.  相似文献   

12.
Matrix-assisted laser desorption/ionization (tandem) mass spectrometry (MALDI MS) is widely used in protein chemistry and proteomics research for the identification and characterization of proteins isolated by polyacrylamide gel electrophoresis. In an effort to minimize sample handling and increase sample throughput, we have developed a novel in-gel digestion protocol where sample preparation is performed directly on a MALDI probe with prestructured sample support. The protocol consists of few sample-handling steps and has minimal consumption of reagents, making the protocol sensitive, timesaving, and cost-efficient. Performance of the on-probe sample preparation protocol was demonstrated by analysis of a set of rat liver proteins obtained from a fluorescently stained (Cy3 and SyproRuby) two-dimensional polyacrylamide gel. The success rate of protein identification by on-probe tryptic digestion and MALDI peptide mass mapping was 89%. The on-probe in-gel digestion procedure provided superior sensitivity and peptide mass mapping performance as compared to our standard in-gel digestion protocol. The on-probe digestion technique resulted in significantly improved amino acid sequence coverage of proteins, mainly due to efficient recovery and detection of large (>1.5 kDa) hydrophobic peptides. These observations indicate that numerous tryptic peptides are lost when using the standard in-gel digestion methods and sample preparation techniques for MALDI MS. This study also demonstrates that the on-probe digestion protocol combined with MALDI tandem mass spectrometry provides a robust platform for proteomics research, including protein identification and determination of posttranslational modifications.  相似文献   

13.
When the mass spectra of biological samples (proteins, peptides, and so on) are obtained routinely by matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), a serious problem is the reduction of the ionization efficiency by impurities, such as buffer salts and detergents. We focused our attention on devising a method to maintain the ionization efficiency of protein samples, even in the presence of sodium dodecyl sulfate (SDS), without any extra purification step. Although no protein ion peaks are observed in the presence of 2.5% SDS with the usual methods, the addition of a granular anion exchange silica gel to the matrix solution allowed the protein ion peaks to be obtained with an excellent signal-to-noise ratio. Together with other supporting experiments, we suggest that the positively charged surface (the basic environment derived from the anion exchange groups) and the roughness of the particles were important for good ionization in the presence of a high SDS concentration. For a very uneven surface, the SDS might be absorbed into the particle interiors during the process of cocrystallization with the matrix and analytes, which is known as the molecular sieve effect, and the SDS concentration in the surface crystalline film might be reduced. As a result, we developed an on-probe sample preparation method without washes for MALDI, using a strong anion exchange silica gel. This method is applicable even in the presence of 2.5% SDS, and is not only very simple but also inexpensive, because it can be used with the standard MALDI target plates.  相似文献   

14.
A new sample ionization technique, atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI), was coupled with a commercial ion trap mass spectrometer. This configuration enables the application-specific selection of external atmospheric ionization sources: the electrospray/APCI (commercially available) and AP MALDI (built in-house), which can be readily interchanged within minutes. The detection limit of the novel AP MALDI/ion trap is 10-50 fmol of analyte deposited on the target surface for a four-component mixture of peptides with 800-1700 molecular weight. The possibility of peptide structural analysis by MS/MS and MS3 experiments for AP MALDI-generated ions was demonstrated for the first time.  相似文献   

15.
Zhou Y  Shen H  Yi T  Wen D  Pang N  Liao J  Liu H 《Analytical chemistry》2008,80(23):8920-8929
We designed and fabricated a novel microdevice to facilitate continuous adsorption phenomena for biological sample preparation. Using the device, we also developed an online, highly integrated, multifunctional strategy, with a promise of accepting a large volume of crude tissue extracts with the end point generation of a reliable MS identification within 20 min. Under an external electric field, charged membranes can adsorb multiple layers of proteins, which exceed the capacity limit of common resins or membranes. It enlarges sample loading and trapping efficiency, thus bypasses the tradeoff between sample capacity and downstream detection sensitivity. This integrated approach, formed by synergistic utilization among electric field, membrane, and fluidic handling at the microscale, reduces the overall complexity of crude samples in one step for direct MS analysis. The sample preparation goals, including enrichment, desalting, removal of noncharged contaminants, and initial fractionation, can be rapidly performed in a single device. The strategy facilitates reproducible MS quantification by circumventing traditional laborious and time-consuming sample preparation steps. In addition, MEPD extended the ion trap linear dynamic range from 2 to at least 4 orders of magnitude by eliminating ion suppression effect, enriching target analyte(s), and decreasing sample loss during integrated sample preparation.  相似文献   

16.
To investigate analyte consumption during the laser desorption process, matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) is combined with radionuclide detection. Radionuclide detection provides highly sensitive and quantitative information on the amount of radiolabeled analytes in a MALDI MS sample spot. 14C-Labeled cytochrome c is deposited with 2,5-dihydroxybenzoic acid in 10-nL volume spots. By comparing radioactivity levels of the labeled cytochrome c both before and after spectral acquisition, the reduction in labeled analyte molecules on the target allows monitoring of the moles of desorbed sample. Through a depletion study on this sample, the amount of analyte consumed for MALDI time-of-flight spectral acquisition and the average number of molecules desorbed per laser ablation are determined. When [14C]-cytochrome c is no longer detected by MALDI MS, approximately 70% of the original analyte remains in the sample spots. Redissolving the spots produced further desorption, indicating that the analyte before dissolution was in a physical environment that did not facilitate the desorption process. As a technique with a response that does not depend on the environment of the analyte, radionuclide detection allows characterization of mass-limited sampling methods to better understand the MALDI process.  相似文献   

17.
We have developed an off-line coupling of capillary electrophoresis (CE) to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry(MALDI-TOF-MS) based on CE fraction collection onto prestructured MALDI sample supports. Analyte carryover and detection sensitivity were investigated using a standard peptide mixture. Low femtomole amounts were detected, and no noticeable carryover was discovered. The performance of the method was evaluated with a mixture of tryptic digests of proteins from a human fetal brain cDNA expression library. The total number of identified peptides was increased from 47 to 211 when the CE-MALDI interface was used compared to direct MALDI-MS analysis. Sequence coverage with CE-MALDI was in the 25-60% range for the different proteins, corresponding to an increase of 1.3-4.9 times relative to that obtained with MALDI-MS of the crude mixture. Fractionation of sample components also facilitated protein identification by MALDI postsource decay analysis. Our initial results suggest this CE-MALDI interface can be used for the analysis of complex peptide mixtures isolated from biological tissues.  相似文献   

18.
Zhang N  Doucette A  Li L 《Analytical chemistry》2001,73(13):2968-2975
Sodium dodecyl sulfate (SDS) is widely used in protein sample workup. However, many mass spectrometric methods cannot tolerate the presence of this strong surfactant in a protein sample. We present a practical and robust technique based on a two-layer matrix/sample deposition method for the analysis of protein and peptide samples containing SDS by matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS). The two-layer method involves the deposition of a mixture of sample and matrix on top of a thin layer of matrix crystals. It was found that for SDS-containing samples, the intensity of the MALDI signals can be affected by the conditions of sample preparation: on-probe washing, choice of matrix, deposition method, solvent system, and protein-to-SDS ratio. However, we found that, under appropriate conditions, the two-layer method gave reliable MALDI signals for samples with levels of SDS up to approximately 1%. The applications of this method are demonstrated for MALDI analysis of hydrophobic membrane proteins as well as bacterial extracts. We envision that this two-layer method capable of handling impure samples including those containing SDS will play an important role in protein molecular weight analysis as well as in proteome identification by MALDI-MS and MS/MS.  相似文献   

19.
The separation of biological mixtures in open micro-channels using electrophoresis with rapid and simple coupling to mass spectrometry is introduced. Rapid open-access channel electrophoresis employs microchannels that are manufactured on microchips. Separation is performed in the open channels, and the chips are transferred to a matrix-assisted laser desorption/ionization (MALDI) source after the solvent is evaporated. The matrix (2,5-dihydroxybenzoic acid) is placed in the solution with the run buffer before the separation of the analyte components. After separation, the solvent is evaporated and the microchip is ready for MALDI-MS analysis. The microchip is placed directly into a specially designed ion source of an external source Fourier transform mass spectrometry instrument. Separation of simple mixtures containing oligosaccharides and peptides is shown.  相似文献   

20.
Identification of individual proteins in complex protein mixtures by high-resolution (HR), high-mass-accuracy matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry (TOF-MS) is demonstrated for synthetic protein mixtures. Instead of chemical denaturation, thermal denaturation followed by in-solution trypsin digestion is used to achieve uniform digestion of the constituents of the protein mixture. Protein identification is carried out using protein database searches with search scoring systems, which seems more effective than conventional peptide mass mapping without using a scoring system. Identification of individual proteins by MALDI HR-TOF-MS peptide mass mapping dramatically reduces data acquisition/analysis time and does not require special equipment for sample preparation/transfer prior to mass spectral analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号