 共查询到20条相似文献,搜索用时 15 毫秒
1.
The main objective of the present study is to investigate the performance characteristics of a solar‐assisted ground‐source heat pump system (SAGSHPS) for greenhouse heating with a 50 m vertical 1¼ in nominal diameter U‐bend ground heat exchanger. This system was designed and installed in the Solar Energy Institute, Ege University, Izmir (568 degree days cooling, base: 22°C, 1226 degree days heating, base: 18°C), Turkey. Based upon the measurements made in the heating mode, the heat extraction rate from the soil is found to be, on average, 54.08 Wm?1 of bore depth, while the required borehole length in meter per kW of heating capacity is obtained as 12.57. The entering water temperature to the unit ranges from 8.2 to 16.2°C, with an average value of 9.1°C. The greenhouse air is at a maximum day temperature of 25°C and night temperature of 14°C with a relative humidity of 40%. The heating coefficient of performance of the heat pump (COPHP) is about 2.13 at the end of a cloudy day, while it is about 2.84 at the end of sunny day and fluctuates between these values in other times. The COP values for the whole system are also obtained to be 5–15% lower than COPHP. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

2.
In this paper, a transcritical carbon dioxide heat pump system driven by solar‐owered CO2 Rankine cycle is proposed for simultaneous heating and cooling applications. Based on the first and second laws of thermodynamics, a theoretical analysis on the performance characteristic is carried out for this solar‐powered heat pump cycle using CO2 as working fluid. Further, the effects of the governing parameters on the performance such as coefficient of performance (COP) and the system exergy destruction rate are investigated numerically. With the simulation results, it is found that, the cooling COP for the transcritical CO2 heat pump syatem is somewhat above 0.3 and the heating COP is above 0.9. It is also concluded that, the performance of the combined transcritical CO2 heat pump system can be significantly improved based on the optimized governing parameters, such as solar radiation, solar collector efficient area, the heat transfer area and the inlet water temperature of heat exchange components, and the CO2 flow rate of two sub‐cycles. Where, the cooling capacity, heating capacity, and exergy destruction rate are found to increase with solar radiation, but the COPs of combined system are decreased with it. Furthermore, in terms of improvement in COPs and reduction in system exergy destruction at the same time, it is more effective to employ a large heat transfer area of heat exchange components in the combined heat pump system. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

3.
This paper presents the thermodynamic and hydrodynamic feasibility of the application of the ammonia–water absorption system for heat or cold transportation over long distance. A model of a long‐distance heat energy transportation system is built and analyzed, and it shows satisfactory and attractive results. When a steam heat source at the temperature of 120°C is available, the user site can get hot water output at about 55°C with the thermal COP of about 0.6 and the electric COP of about 100 in winter, and cold water output at about 8°C with the thermal COP of about 0.5 and the electric COP of 50 in summer. A small‐size prototype is built to verify the performance analysis. Basically the experimental data show good accordance with the analysis results. The ammonia–water absorption system is a potential prospective solution for the heat or cold transportation over long distance. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
The present study was aimed to utilize low‐cost alumina (Al2O3) nanoparticles for improving the heat transfer behavior in an intercooler of two‐stage air compressor. Experimental investigation was carried out with three different volume concentrations of 0.5%, 0.75%, and 1.0% Al2O3/water nanofluids to assess the performance of the intercooler, that is, counterflow heat exchanger at different loads. Thermal properties such as thermal conductivity and overall heat transfer coefficient of nanofluid increased substantially with increasing concentration of Al2O3 nanoparticles. Specific heat capacity of nanofluids were lower than base water. The intercooler performance parameters such as effectiveness and efficiency improved appreciably with the employment of nanofluid. The efficiency increased by about 6.1% with maximum concentration of nanofluid, that is, 1% at 3‐bar compressor load. It is concluded from the study that high concentration of Al2O3 nanoparticles dispersion in water would offer better heat transfer performance of the intercooler.  相似文献   

5.
This paper aims to study the effect on the characteristics of molten salt because of the dispersion of different size nanoparticles of Al2O3. The eutectic mixture of 54 wt% KNO3 and 46 wt% NaNO3 was selected as the base salt. Five different size nanoparticles of Al2O3, 80, 135, 200, 300, and 1000 nm, were dispersed into the base salt at a mass concentration of 1% to make the nanomaterials by a two‐step method, respectively. Thermal properties of the base salt and the samples with Al2O3 nanoparticles, including the melting point temperature, fusion heat, specific heat capacity, and thermal diffusivity, were measured with differential scanning calorimeter (DSC) and Xenon Flash Apparatus (XFA). On the basis of the measured specific heat capacities and thermal diffusivities, their thermal conductivities in the solid state were calculated at discrete specified temperatures. The results showed that the dispersions of 200‐ and 135‐nm Al2O3 nanoparticles could enhance the average solid and liquid specific heat capacities by up to 17.2% and 19.7%, respectively. The research on thermal diffusivity and thermal conductivity also verified that the influences of different size nanoparticles were different. Although no new strong intensity peaks or peak position variations were found in the diffraction patterns of the two samples with 80‐ and 1000‐nm nanoparticles of Al2O3, the larger deviations in the lower wavenumber region still meant possible crystalline structure variation because of the dispersion of Al2O3 nanoparticles. Scanning electronic microscope (SEM) images showed the inhomogeneity and the agglomeration of dispersed nanoparticles in the base salt, and the formation of a nanolayer around the nanoparticles could be a possible explanation to the thermal‐physical property variation.  相似文献   

6.
Shell and tube heat exchanger is one of the most prevalent heat exchangers with a wide variety of industrial applications, i.e., power plants, chemical processes, marine industries, HVAC systems, cooling of hydraulic fluid and engine oil in heavy duty diesel engines and the like specifically where a need to heat or cool a large fluid volume exist and also higher-pressure use. In the present study, the effect of using Al2O3-water nanofluid on thermal performance of a commercial shell and tube heat exchanger with segmental baffles is assessed experimentally. For this purpose, Al2O3-gamma nanoparticles with 15 nm mean diameter (99.5% purity) and Sodium Dodecyl Benzene Sulphonate (SDBS) as surfactant are used to make aqueous Al2O3 nanofluid at three various volume fractions of nanoparticles (φ = 0.03, 0.14 and 0.3%). Indeed, in this paper the effect of some parameters of hot working fluid such as Reynolds number and volume concentration of nanoparticles on heat transfer characteristics, friction factor and thermal performance factor of a shell and tube heat exchanger under laminar flow regime is investigated. The results indicate a substantial increment in Nusselt number as well as the overall heat transfer coefficient of heat exchanger by enhancement of Reynolds number and it can be seen that, at a certain Reynolds number, heat transfer characteristics of heat exchanger increase as the nanoparticles volume concentration increases. Outcomes of the heat transfer evaluation demonstrate that applying nanofluids instead of base fluid lead to increment of Nusselt number up to 9.7, 20.9 and 29.8% at 0.03, 0.14 and 0.3 vol%, respectively. Likewise it is seen that at mentioned nanoparticles volume fractions, overall heat transfer coefficient of heat exchanger enhances around 5.4, 10.3 and 19.1%, respectively. In term of pressure drop, a little penalty is found by using nanofluid in the test section. Eventually a thermal performance assessment on the heat exchanger was conducted. According to the analysis results, utilizing nanofluid at minimum and maximum nanoparticles volume fractions (φ = 0.03 and 0.3%) results in average augmentation of around 6.5% and 18.9% in thermal performance factor (η) of the heat exchanger compared to the base liquid, respectively.  相似文献   

7.
Aiming at developing exhaust gas-driven automobile air conditioners, two types of systems varying in heat carriers were preliminarily designed. A new hydride pair LaNi4.61Mn0.26Al0.13/La0.6Y0.4Ni4.8Mn0.2 was developed working at 120–200 °C/20–50 °C/−10–0 °C. P-C isotherms and reaction kinetics were tested. Reaction enthalpy, entropy and theoretical cycling coefficient of performance (COP) were deducted from Van’t-Hoff diagram. Test results showed that the hydride pair has flat plateau slopes, fast reaction dynamics and small hystereses; the reaction enthalpy of the refrigeration hydride is −27.1 kJ/mol H2 and system theoretical COP is 0.711. Mean particle sizes during cycles were verified to be an intrinsic property affected by constitution, heat treatment and cycle numbers rather than initial grain sizes. Based on this work pair, cylindrical reactors were designed and a function proving metal hydride intermittent refrigeration system was constructed with heat conducting oil as heat source and water as heat sink. The reactor equivalent thermal conductivity is merely 1.3 W/(m K), which still has not meet practical requirement. Intermittent refrigeration cycles were achieved and the average cooling power is 84.6 W at 150 °C/30 °C/0 °C with COP being 0.26. The regulations of cycling performance and minimum refrigeration temperature (MRT) were determined by altering heat source temperature. Results showed that cooling power and system COP increase while MRT decreases with the growth of heat source temperature. This study develops a new hydride pair and confirms its application in automobile refrigeration systems, while their heat transfer properties still need to be improved for better performance.  相似文献   

8.
A cycle analysis of a CO2 air conditioner is presented in this study. It is shown that the effect of internal superheating on the system coefficient of performance (COP) is very small for a system using a semi-hermetic compressor. However, the compressor efficiency has a significant effect on the system COP. The design of the recuperative heat exchanger in a system is crucial, since the system COP may decrease when the size of the recuperator is larger than a certain size.  相似文献   

9.
This paper presents the cooling performance of a water-to-refrigerant type ground heat source heat pump system (GSHP) installed in a school building in Korea. The evaluation of the cooling performance has been conducted under the actual operation of GSHP system in the summer of year 2007. Ten heat pump units with the capacity of 10 HP each were installed in the building. Also, a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth was constructed for the GSHP system. To analyze the cooling performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the water temperature of inlet and outlet of the ground heat exchanger. Simultaneously, the cooling capacity and the input power were evaluated to determine the cooling performance of the GSHP system. The average cooling coefficient of performance (COP) and overall COP of the GSHP system were found to be ~8.3 and ~5.9 at 65% partial load condition, respectively. While the air source heat pump (ASHP) system, which has the same capacity with the GSHP system, was found to have the average COP of ~3.9 and overall COP of ~3.4, implying that the GSHP system is more efficient than the ASHP system due to its lower temperature of condenser.  相似文献   

10.
Theoretical analyses and optimisation are carried out with ethane, ethylene and nitrous oxide as the low-temperature (LT) fluids in a cascade system for ultra-low-temperature refrigeration applications to examine the effects of design and operating parameters. Finally, performance improvement has been investigated employing an internal heat exchanger. Optimal intermediate temperature (IT) correlations have been developed. Ethane is superior in terms of coefficient of performance (COP), whereas nitrous oxide is superior in terms of volumetric cooling capacity as an LT fluid. With increase in compressor efficiency, COP increases; however, with little influence on the optimum IT. Using an internal heat exchanger in the LT circuit, the cooling COP can be increased for ethane and ethylene; however, there is marginal decrease in COP for N 2O. Ammonia is not suitable as a HT fluid for some operating conditions where the optimum IT is lower than the normal boiling point and propylene may be a suitable substitute with a penalty on COP.  相似文献   

11.
Heat transfer and hydrodynamic performances for nanofluids, Al2O3‐water and SiO2‐water, are numerically investigated with different nanoparticles’ volume fractions and the initial velocities in a fractal microchannel heat sink. The fractal microchannel is 100 μm × 100 μm in the inlet cross‐section, and the length at the 0th level is 2000 μm. A constant heat flux of 500 kW/m2 was applied to the bottom wall of the fractal microchannel heat sink. The heat transfer and hydrodynamic performances of different cases are discussed in terms of the mean heat transfer coefficient, mean base temperature, pressure loss, thermal resistance, friction factor f/f0, and COP/COP0. Results indicate that increasing the initial velocity and nanoparticles’ volume fraction lead to an enhanced heat transfer at the expense of pressure loss. Al2O3‐water has a higher mean heat transfer coefficient and pressure drop than that of SiO2‐water, a lower f/f0, mean base temperature, thermal resistance, and COP/COP0. Ultimately, as compared to pure water, the heat transfer coefficients of 4% Al2O3‐water increased by 7.53%, 7.80%, 8.00%, 8.14%, 8.16%, and 8.30%, and the pressure drops increased by 32.09%, 31.41%, 30.81%, 30.05%, 29.21%, and 28.58%, respectively, corresponding to the initial velocities by 4, 5, 6, 7, 8 and 9 m/s.  相似文献   

12.
The present paper deals with the design and optimization of a heat driven thermoacoustic refrigerator. A simplified model is developed which enables to pinpoint and examine the most important physical characteristics of a compact traveling wave thermoacoustic refrigerator driven by a traveling wave thermoacoustic engine. The model can explain the so-called traveling standing wave effect in thermoacoustics very well. The position, length and hydraulic radius of the refrigerator are optimized for the maximum total COP. The prime mover efficiency, refrigerator COP and dimensionless dissipation and their impacts on total COP are investigated and discussed. The results indicate that a COP of 28.7% at TRF,cold = 273 K is achievable.  相似文献   

13.
In the present study, the first and second laws of thermodynamic have been used to analyse in detail the performance of a heat transformer used for water purification. The heat delivered in the auxiliary condenser is recycled into the system increasing the heat source temperatures and therefore the coefficient of performance (COP) and the exergy coefficient of performance (ECOP). Plots of COP, ECOP, the improvement potential (IP) and the cycle irreversibility (ICYCLE) are shown against the main operating temperatures of the system, the gross temperature lift (GTL), the flow ratio (FR) and the effectiveness of the economiser (EFEC). In order to found the components of the system with the highest irreversibilities, plots of the irreversibilities for each one of the main components of the system are reported against the main temperatures and operating parameters of the heat transformer. The results showed that the highest irreversibilities occurred in the absorber contributing with more than the 30% of the irreversibilities of the entire system, followed by the auxiliary condenser with about the 25%. The lowest irreversibilities were found in the pumps which are almost negligible and in the economiser which were in general lower than 5%.  相似文献   

14.
《Applied Thermal Engineering》2003,23(13):1577-1593
In the absorption refrigeration system (ARS) working with aqua–ammonia, the ejector is commonly located at the condenser inlet. In this study, the ejector was located at the absorber inlet. Therefore, the absorber pressure becomes higher than the evaporator pressure and the system works with triple-pressure-level. The ejector has two main functions: (i) aiding pressure recovery from the evaporator, (ii) upgrading the mixing process and the pre-absorption by the weak solution of the ammonia coming from the evaporator. In addition to these functions, it can also act to lower the refrigeration and heat-source temperatures. Energy analyses show that the system’s coefficient of performance (COP) and exergetic coefficient of performance (ECOP) were improved by 49% and 56%, respectively and the circulation ratio (f) was reduced by 57% when ARS is initiated at lower generator temperatures. Due to the reduced circulation ratio, the system dimensions can be reduced; consequently, this decreases overall cost. The heat source and refrigeration temperatures decreased in the range of 5–15 °C and 1–3 °C, respectively. Exergy analyses show that the exergy loss of the absorber of ARS with ejector had a higher exergy loss than those of the other components. Therefore, a multiple compartment absorber can be proposed to reduce the exergy loss of the absorber of ARS with ejector.  相似文献   

15.
This article experimentally investigates the enhancement of thermal performance for an air conditioning system utilizing a cold storage unit as a subcooler. The cold storage unit is composed of an energy storage tank, liquid-side heat exchanger, suction-side heat exchanger and energy storage material (ESM), water. When the cooling load is lower than the nominal cooling capacity of the system, the cold storage unit can store extra cold energy of the system to subcool the condenser outlet refrigerant. Hence, both the cooling capacity and coefficient of performance (COP) of the system will be increased. This experiment tests the two operation modes: subcooled mode with energy storage and non-subcooled mode without energy storage. The results show that for fixed cooling loads at 3.05 kW, 3.5 kW and 3.95 kW, the COP of the subcooled mode are 16.0%, 15.6% and 14.1% higher than those of the non-subcooled mode, respectively. In the varied cooling load experiments, the COP of the subcooled cold storage air conditioning system is 15.3% higher than the conventional system.  相似文献   

16.
Heat activated cooling has the potential of utilizing thermal sources that currently go unused such as engine exhaust heat or industrial waste heat. Using these heat sources can provide enhanced energy utilization and reduced fuel usage in applications where cooling is needed. The concept developed here uses waste heat from stationary and mobile engine cycles to generate cooling for structures and vehicles. It combines an organic Rankine cycle (ORC) with a conventional vapor compression cycle. A nominal 5 kW cooling capacity prototype system was developed based on this concept and tested under laboratory conditions. In order to maintain high system performance while reducing size and weight for portable applications, microchannel based heat transfer components and scroll based expansion and compression were used. Although the system was tested off of its design point, it performed well achieving 4.4 kW of cooling at a measured heat activated COP of 0.48. Both the conversion and 2nd law efficiencies were close to the model results, proving it to be an attractive technology. The measured isentropic efficiency of the scroll expander reached 84%, when the pressure ratio was close to the scroll intrinsic expansion ratio. The reduced cooling capacity was attributed to off design operation.  相似文献   

17.
Experimental study of photovoltaic solar assisted heat pump system   总被引:3,自引:0,他引:3  
A novel photovoltaic solar assisted heat pump (PV-SAHP) system has been proposed in this study. Performance tests with a range of condenser supply water temperature were conducted on an experimental rig. The dynamic performance of this PV-SAHP system in a 4-day period with very similar weather conditions was analyzed and the influencing factors were identified. The results indicate that this PV-SAHP system has a superior coefficient of performance (COP) than the conventional heat pump system and at the same time, the photovoltaic efficiency is also higher. The COP of the heat pump was able to reach 10.4 and the average value was about 5.4. The average photovoltaic efficiency was around 13.4%. The highest overall coefficient of performance (COPp/t), bringing into consideration both the photovoltaic and thermal efficiency, was about 16.1.  相似文献   

18.
This paper reports on the investigation of pool boiling heat transfer of γ-Al2O3/CMC non-Newtonian nanofluids. To prepare nanofluids, γ-Al2O3 nanoparticles were dispersed in CMC solution (carboxy methyl cellulose in water) using ultrasonic mixing and mechanical mixer. Different concentrations of CMC non-Newtonian fluids and γ-Al2O3/CMC non-Newtonian nanofluids were tested under nucleate pool boiling heat transfer conditions. Experiments were carried out at atmospheric pressure. Results show that the pool boiling heat transfer coefficient of CMC solutions is lower than water. The decrease in boiling heat transfer is more pronounced at higher CMC concentrations and, as a result, higher solution viscosity. Adding nanoparticles to CMC non-Newtonian solutions results in an improved boiling heat transfer performance. The enhancement in the boiling heat transfer coefficient increases with the nanoparticle concentration; at a concentration of 1.4 wt.%, the boiling heat transfer coefficient increases by about 25% when compared to the base fluid.  相似文献   

19.
Numerous authors have reported heat transfer prediction using artificial neural network (ANN). However, the precision or accuracy of the calculation is generally unknown. Error propagation from Monte Carlo method is applied to the coefficient of performance (COP) predicted by ANN. This COP permitted us to evaluate a water purification process integrated into a heat transformer. A feedforward network with a hidden layer was used in order to obtain error propagation in COP prediction. This model used the input and output-temperatures for each component (absorber, generator, evaporator, and condenser), as well as two pressure parameters from the absorption heat transformer and LiBr + H2O mixture with different LiBr concentrations. The hyperbolic tangent sigmoid transfer-function and the linear transfer-function were used for the network. A new correlation for calculating relative standard deviation (%RSDCOP) of COP as a function of COPEXP and %RSDinstrument was obtained. This study shows that %RSDCOP of ANN prediction decreased when the experimental COP is increased. The range of COP operations was from 0.21 to 0.39.  相似文献   

20.
In this paper, an experimental performance evaluation of a direct expansion ground‐coupled heat pump (DX‐GCHP) system in heating mode is presented. The DX‐GCHP uses R134a as the refrigerant, and consists of three single U‐tube copper ground heat exchangers (GHEs) placed in three 30 m vertical boreholes. During the on–off operations from December 25, 2007, to February 6, 2008, the heat pump supplied hot water to fan‐coil at around 50.4°C, and its heating capacity was about 6.43 kW. The energy‐based heating coefficient of performance (COP) values of the heat pump and the whole system were found to be on average 3.55 and 3.28 at an evaporating temperature of 3.14°C and a condensing temperature of 53.4°C, respectively. The second law efficiency on the DX‐GCHP unit basis was around 0.36. The exergetic COP values of the heat pump and the whole system were obtained to be 0.599 and 0.553 (the reference state temperature was set equal to the average outdoor temperature of ?1.66°C during the tests), respectively. The authors also discussed some practical points such as the heat extraction rate from the ground, refrigerant charge and two possible new configurations to simultaneously deal with maldistribution and instability of parallel GHE evaporators. This paper may reveal insights that will aid more efficient design and improvement for potential investigators, designers and operators of such DX‐GCHP systems. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   