全文获取类型
收费全文 | 154篇 |
免费 | 40篇 |
国内免费 | 8篇 |
专业分类
电工技术 | 103篇 |
综合类 | 7篇 |
机械仪表 | 15篇 |
建筑科学 | 3篇 |
矿业工程 | 2篇 |
能源动力 | 15篇 |
轻工业 | 1篇 |
无线电 | 39篇 |
一般工业技术 | 1篇 |
自动化技术 | 16篇 |
出版年
2023年 | 4篇 |
2022年 | 4篇 |
2021年 | 9篇 |
2020年 | 4篇 |
2019年 | 3篇 |
2018年 | 4篇 |
2017年 | 19篇 |
2016年 | 12篇 |
2015年 | 7篇 |
2014年 | 17篇 |
2013年 | 16篇 |
2012年 | 15篇 |
2011年 | 16篇 |
2010年 | 10篇 |
2009年 | 14篇 |
2008年 | 7篇 |
2007年 | 11篇 |
2006年 | 6篇 |
2005年 | 4篇 |
2004年 | 6篇 |
2003年 | 6篇 |
2002年 | 6篇 |
2000年 | 2篇 |
排序方式: 共有202条查询结果,搜索用时 15 毫秒
1.
This paper proposes a new multi-objective framework for optimal placement and sizing of the active power filters (APFs) with satisfactory and acceptable standard levels. total harmonic distortion (THD) of voltage, harmonic transmission line loss (HTLL), motor load loss function (MLLF), and total APFs currents are the four objectives considered in the optimization, while harmonic distortions within standard level, and maximum allowable APF size, are modeled as constraints. The proposed model is one of non-convex optimization problem having a non-linear, mixed-integer nature. Since, a new modified harmony search algorithm (MHSA) is used and followed by a min–max technique in order to obtain the final optimal solution. The harmony search algorithm is a recently developed optimization algorithm, which imitates the music improvisation process. In this process, the Harmonists improvise their instrument pitches searching for the perfect state of harmony. The newly developed method has been applied on the IEEE 18-bus test system and IEEE 30-bus test system by different scenarios and cases to demonstrate the feasibility and effectiveness of the proposed method. The detailed results of the case studies are presented and thoroughly analyzed. The obtained results illustrate the sufficiency and profitableness of the newly developed method in the placement and sizing of the multiple active power filters, when compared with other methods. 相似文献
2.
3.
This paper addresses the optimal distributed generation sizing and siting for voltage profile improvement, power losses, and total harmonic distortion (THD) reduction in a distribution network with high penetration of non-linear loads. The proposed planning methodology takes into consideration the load profile, the frequency spectrum of non-linear loads, and the technical constraints such as voltage limits at different buses (slack and load buses) of the system, feeder capacity, THD limits, and maximum penetration limit of DG units. The optimization process is based on the Genetic Algorithm (GA) method with three scenarios of objective function: system power losses, THD, and multi-objective function-based power losses and THD. This method is executed on the IEEE 31-bus system under sinusoidal and non-sinusoidal (harmonics) operating conditions including load variations within the 24-hr period. The simulation results using Matlab environment show the robustness of this method in optimal sizing and siting of DG, efficiency for improvement of voltage profile, reduction of power losses, and THD. A comparison with particle swarm optimization (PSO) method shows that the proposed method is better than PSO in reducing the power losses and THD in all suggested scenarios. 相似文献
4.
Mohsen Hosseinzadeh Soreshjani Navidreza Abjadi Gholamreza Arab Markadeh 《International Journal of Circuit Theory and Applications》2015,43(10):1491-1507
In this study, a Z‐source alternating current‐to‐alternating current (AC–AC) converter with a specific topology, which can provide both buck and boost modes, is investigated. This converter, which can be implemented easily, utilizes only two switches with complemented commands. A comparison between the Z‐source AC–AC converter and a conventional thyristor voltage controlled one is presented here, and it shows that in the most areas, the Z‐source converter provides a faster response and lower total harmonic distortion of the output currents than the conventional one. Moreover, the Z‐source converter is also extended to the multiphase systems. In addition, a new arrangement of this converter is proposed here to remove the isolated single‐phase sources. Furthermore, an open‐loop method is proposed for soft‐starting applications. Finally, a closed‐loop control system is also suggested for a three‐phase Z‐source converter to soft start and control the speed of an induction motor. Computer simulations show the validity and effectiveness of the proposed schemes. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
5.
Realization of active power filter with Model Based Design approach is presented in this paper. The approach adopts different modeling platforms as well as selection of proper hardware for step wise verification and testing. The active power filter model is developed using the Matlab/Simulink platform for single phase. The efficiency of the control algorithms such as synchronous detection method and indirect current control for active power filter is analyzed. Efficient control algorithm is developed by Xilinx system generator which is incorporated into Simulink as Xilinx tool box. Xilinx system generator provides a virtual platform for easy and effective design of the required system models in FPGA (field programmable gate array) design environments. Optimized automatic VHDL code is generated for the control algorithm which is simulated using ISE 13.2 for the generation of switching signals for the control of IGBTs of the active power filter. Suitable compensation signal is generated from the active power filter for the better elimination harmonics to improve the power quality. THD is reduced to a considered value which is able to satisfy the limits of the IEEE standard. 相似文献
6.
7.
Sung-Geun SongSung-Jun Park Yeun-Ho JoungFeel-soon Kang 《Electric Power Systems Research》2011,81(8):1672-1680
In multilevel inverter development for 3-phase applications, total number of transformer in the circuit can be reduced by using of cascaded 3-phase transformer circuit instead of single-phase transformer circuit. In the scheme, total number of switching components in the circuit is still a drawback to achieve lower cost and smaller size of the inverter compared with conventional multilevel inverter. This paper includes a challenging method to reduce total switching components in the multilevel inverter by adopting common-arm structure.The proposed inverter has been operated by two control schemes, Newton-Raphson and Equal-area method. After theoretical and experimental comparison of the methods, we found that Newton-Raphson method is useful to eliminate a specific harmonic order. However, the method has a shortcoming in real time operation which is performed by iterative calculation of the nonlinear equations. With Equal-area method, we can easily find the switching angles by calculating a trigonometric function. It can sufficiently minimize Total Harmonic Distortion (THD) of output voltage in real time operation of Digital Signal Processor (DSP). 相似文献
8.
通过严格的推导得出了一种实用谐波损耗计算方法,该方法计算过程简单.所需数据可以直接从电能质量监测仪中得到,在基波损耗已算出的情况下,就可以准确的计算出谐波损耗.将谐波网损从管理线损中剥离出来,一方面理论线损计算更进一步接近真实值,有利于有效降损措施的提出;另一方面也为谐波污染治理提供了有力的手段. 相似文献
9.
10.
级联型多电平变频器不同阶梯波调制算法的谐波分析 总被引:2,自引:1,他引:1
级联型多电平变频器中阶梯波算法的优点是开关频率低,转换效率高.介绍和分析了几种阶梯波算法,并对其输出波形的频谱和谐波总含量进行仿真和比较,得出相关结论,以期为实际工程应用提供理论依据. 相似文献