Supported metal catalysts, particularly noble metals supported on SiO2, have attracted considerable attention due to the importance of the silica–metal interface in heterogeneous catalysis and in electronic device fabrication. Several important issues, e.g., the stability of the metal–oxide interface at working temperatures and pressures, are not well-understood. In this review, the present status of our understanding of the metal–silica interface is reviewed. Recent results of model studies in our laboratories on Pd/SiO2/Mo(1 1 2) using LEED, AES and STM are reported. In this work, epitaxial, ultrathin, well-ordered SiO2 films were grown on a Mo(1 1 2) substrate to circumvent complications that frequently arise from the silica–silicon interface present in silica thin films grown on silicon. 相似文献
Work system improvements are implemented in various manufacturing processes to prevent problems caused by human errors. However, they are almost always applied to problems which have already occurred. This paper examines a method of identifying latent human errors existing within the work systems beforehand. A procedure for applying failure mode and effect analysis to this identification problem was defined based on over 1000 empirical errors: a work system decomposition criterion and fundamental error modes for listing latent human errors, and then applied to three practical manufacturing processes in order to evaluate its effectiveness. 相似文献
This paper presents a model of heterogenous diffusion in capillary porous materials during the process of drying. The governing heat and mass transfer equations have been established using the liquid as well as vapor flow. Two models have been presented. Model 1 does not consider the heat conduction while the model 2 has been established by considering the conduction. The developed models and the numerical solutions of the resulting differential equations can take into account the moisture and temperature dependent thermophysical properties of the product. All equations have been established in spherical coordinates but the programme written for the purpose of calculations can be used for other geometries also. Numerical calculations have been performed for gas concrete and tiles using model 1, while model 2 has been used for gas concrete only because of the lack of data for thermophysical properties of the tile. For gas concrete it was seen that conduction has only marginal effect on the drying process and the numerical predictions of the drying process were reasonably accurate. 相似文献
A CEC-funded project has been performed to tackle the problem of producing an advanced Life Monitoring System (LMS) which would calculate the creep and fatigue damage experienced by high temperature pipework components. Four areas were identified where existing Life Monitoring System technology could be improved:
1. 1. the inclusion of creep relaxation
2. 2. the inclusion of external loads on components
3. 3. a more accurate method of calculating thermal stresses due to temperature transients
4. 4. the inclusion of high cycle fatigue terms.
The creep relaxation problem was solved using stress reduction factors in an analytical in-elastic stress calculation. The stress reduction factors were produced for a number of common geometries and materials by means of non-linear finite element analysis. External loads were catered for by producing influence coefficients from in-elastic analysis of the particular piping system and using them to calculate bending moments at critical positions on the pipework from load and displacement measurements made at the convenient points at the pipework. The thermal stress problem was solved by producing a completely new solution based on Green's Function and Fast Fourier transforms. This allowed the thermal stress in a complex component to be calculated from simple non-intrusive thermocouple measurements made on the outside of the component. The high-cycle fatigue problem was dealt with precalculating the fatigue damage associated with standard transients and adding this damage to cumulative total when a transient occurred.
The site testing provided good practical experience and showed up problems which would not otherwise have been detected. 相似文献
Summary The effect of the addition of four commercial pectolytic preparations on the visual characteristics (colour and turbidity) of red wines has been evaluated. The effect of both clarifying and colour extracting enzymes and the effect of different doses used, were evaluated and compared. All the red wines treated enzymatically, independent of the type of enzyme and dose, present chromatic characteristics which can be considered better than those of the control wines. Also, those wines treated with enzymes had greater stability during 2 years storage in bottles, in particular the turbidity was better than untreated wines. 相似文献
This paper presents a new computerized procedure for dealing with the design of horizontal ground heat exchangers (HGHE). The computer program is based on the transient model of coupled nonlinear partial differential equations governing heat and mass flow in soils. The model is two-dimensional and delineates the operation of ground heat storage with the HGHE and such phenomena as freezing/thawing and drying/rewetting of soil moisture. Comprehensive climatological data, such as ambient temperature, solar radiation, wind velocity, rainfall, snowfall, snow characterstics, and water vapour pressure is used to simulate conditions at the ground surface over any required length of time. The package can be applied to any geographical location by changing climatic and soil data input. The designer has the possibility of selecting any of 12 types of soils from sand to clay, 12 commercial heat pumps, nine different configurations of the HGHE, 16 plastic pipes for ground coils, and 13 ground coil fluids. The program, however, does not calculate the length of the HGHE but it evaluates the thermodynamic performance of a ground heat pump system and provides comprehensive data on thermal and hydraulic conditions in ground heat storage. The length of the ground heat exchanger is obtained from a line source theory model or from site dimensions and pipe spacing. Computed results for ground heat exchanger operation correlate fairly well with experimental data. Simulation of temperature and moisture content in the ground for natural conditions (no heat extraction/deposition) showed a fair agreement with field data. The entire computer program is user-friendly, interactive, menu-driven, and written in FORTRAN 77. 相似文献
Since electronic switching systems usually require very strict reliability requirements as well as good performance objectives, we need to jointly analyse the performance and reliability of switching systems. In this paper, we compare conventional time–space–time switches with single space switches with those with multiple separated space switches, from the viewpoints of reliability and performance. We consider time–space–time switching networks which consist of N incoming time switches, i.e. one NxN space switch, two (N/2)x(N/2) space switches, and four (N/4)x(N/4) space switches. We introduce a Markov reliability model to study the effect of failures and analyse the reliability and performance of three different types of switching networks in terms of average blocking probability and the mean time to unreliable operation, as we vary the offered traffic. As a result, T–S–T switching networks with multiple separated space switches exhibit better performance and reliability than those with single space switches. 相似文献