首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
选取104例疑似或确诊的冠心病患者行腺苷负荷 静息门控心肌灌注断层显像,研究了一日法负荷-静息显像判断静息与负荷状态左室功能的差异及与心肌缺血之间的关系。将左室分为17节段,采用5点评分法对心肌缺血进行评分,并计算出总负荷评分(SSS)、总静息评分(SRS)及评分差( SDS =SSS-SRS)。将SSS≥4作为存在缺血指标,SDS≥3为可逆性灌注异常指标。结果显示,负荷与静息显像左心室射血分数LVEF有很好的相关性。以所有患者为整体来观察,静息显像与负荷显像间无显著性差异(t=-0.655,P>0.05)。将所有患者分为可逆心肌缺血组及非可逆心肌缺血组,非可逆心肌缺血患者组静息及负荷后LVEF、EDV(舒张末容积)、ESV(收缩末容积)之间均无显著差异;而可逆心肌缺血组负荷显像LVEF、EDV、ESV均显著低于静息显像。以上结果提示,腺苷诱导可逆性缺血患者负荷显像LVEF明显低于静息显像;负荷显像LVEF有所降低,也预示其心肌缺血的可能性明显增加。  相似文献   

2.
门控心肌显像在冠心病诊断及心功能评价中的应用   总被引:5,自引:0,他引:5  
梁宏  石锐 《核技术》1994,17(11):664-667
报道了18例正常人、118例冠心病(CHD)患者的(99m)TC-MIBI心肌显像结果,心肌断层靶心图显示诊断CHD的灵敏度达90.7%,门控心肌图像观察结合左室心肌收缩分数(LVCF)分析其诊断灵敏度为83.3%;二者特异性相似.探讨了密度法计算LVCF的方法,并与心血池显像的左室射血分数(LVEF)做了相关分析,结果表明:应用密度法计算LVCF重复性好,与左室LVEF具有良好相关,相关系数为0.86,并能通过回归公式预测。52例受检者门控心肌显像所观察到的左室室壁运动结果与心血池显像有良好的一致.  相似文献   

3.
林伟  叶广春 《核技术》1994,17(5):258-260
对30例病人进行了门电路心血池断层及平面显像,发现断层显像LVEF与平面显像LVEF呈良好正相关(r>0.7,P<0.0001),而断层显像RVEF与平面显像RVEF无相关关系(r<0.5,P>0.05)。左右心室舒张末期及收缩末期容积有显著性差异(P<0.05),门电路心血池断层显像能够克服平面显像心房心室互相重叠的影响。有利于对左右心室底部及间隔病变的检查。  相似文献   

4.
建立一日法口服乙酰唑胺(ACZ)负荷脑血流显像技术并探讨其临床价值.对30名缺血性脑血管病患者在一日内行静息显像和口服乙酰唑胺负荷显像.观察负荷前后脑血管反应性和比较静息显像、负荷显像和CT检查三者的阳性率.结果是大脑皮质对乙酰唑胺的反应可分为四种类型;CT、静息显像和负荷检查的阳性率分别为23.3%、26.7%、86.7%.负荷显像阳性率高于单纯静息显像(p<0.05)和CT检查(p<0.01).结论是一日法口服乙酰唑胺负荷显像省时并且经济,可提高缺血性脑血管疾病的诊断率,并反映血管储备能力,值得推广.  相似文献   

5.
借助心脏模型和临床研究,探讨了心肌断层显像180°采集方式的可行性,并与360°资料采集进行了比较。评价参数主要有心肌容积和面积、缺损容积和面积。结果表明;单用心脏模型时,360°方式与模型真实值较为接近,而外附体模后,180°采集更符合真实值,但相互间均无显著性差异(P>0.05)。34例冠心病患者心肌病变定量参数360°/°与180°间或180°/6°与180°矿间均非常接近;而且180°/6°采集时其缺损(病变)/正常心肌比率(0.235±0.043)较360°/6°采集(0.249±0.057)明显降低(P<0.05),表明前者能更好地分辨病变区。上述结果提示:心肌断层显像时,180°采集不但能与360°采集一样提供较好的图像,而且能减少图像采集时间,故更具有临床应用价值。  相似文献   

6.
探讨99mTc-甲氧基异丁基异腈(MIBI)门控心肌灌注显像所获得的室壁增厚信息在判断冠心病心肌梗死患者中存活心肌的价值.26例确诊的冠心病心肌梗死的男性患者,均在2周内完成12导联心电图(EKG)、99mTc-MIBI静息门控心肌灌注显像、18F-脱氧葡萄糖(FDG)心肌代谢显像,所有病人均接受冠状动脉造影(CAG).在双核素心肌显像结果提示为缺血存活心肌的心肌节段中,MIBI分布缺损但室壁增厚(WT)正常的心肌节段占双核素显像结果提示为缺血存活心肌节段的68.2%;在双核素心肌显像结果提示为梗死心肌的心肌节段中,MIBI分布缺损且WT异常的心肌节段占双核素显像结果提示为梗死心肌节段的96.8%.静息门控心肌灌注显像所获得的血流灌注和室壁增厚信息与99mTc-MIBI/18F-FDG双核素心肌显像结果具有较高的符合率,故在单纯的心肌血流灌注图像的基础上,结合室壁增厚信息与传统的心肌灌注显像相比有助于检出更多的存活心肌.  相似文献   

7.
^99mTc—MIBI心肌断层显像图像采集方法比较   总被引:1,自引:0,他引:1  
梁宏  石锐 《核技术》1996,19(5):285-288
借助心脏模型和临床研究,探讨了心肌断层显像180°采集方式的可行性,并与360°资料采集进行了比较。评价参数主要有心肌容积和面积、缺损容积和面积。结果表明:单用心脏模型时,360°方式与模型真实值较为接近,而外附体模后,180°采集更符合真实值,但相互间均无显性差异(P〉0.05)。34例冠心病患心肌病变定量参数360°/6°与180°/3°间均非常接近;而且180°/6°采集时其缺损(病变)  相似文献   

8.
本文从核素心血池显像为基础,设计了右房舒张早期排空率(RAER)参数。19例正常对照组,15例慢性阻塞性肺疾病(COPD)组的研究显示,RAER参数对肺动脉高压的诊断灵敏性82%,特异性75%,与平均肺动脉压间呈中度负相关,r=-0.61,p〈0.05。结果表明RAER参数对肺动脉高压诊断具有一定价值。  相似文献   

9.
99TcmN-NOET心肺比值在冠心病诊断中的价值   总被引:3,自引:0,他引:3  
评价99TcmN-NOET运动-延迟心肌灌注显像测得的心肺比值(HLR)与冠心病之间的关系.10名正常志愿者(男7例,女3例,平均年龄40.0±5.8岁),40名拟诊冠心病患者(男21例,女19例,平均年龄55.2±8.5岁)进行了99TcmN-NOET运动-延迟心肌灌注显像(运动显像在注药后30 min进行,延迟显像在注药后2 h和4 h分别进行),并测定了相应时间的HLR.其中13名患者在显像后2个月内接受了冠状动脉造影检查.根据运动显像时测得的HLR(EXHLR)的不同,将50例受检者分成2组.第1组(G1),n=36,EXHLR≥2,包括10名正常人和5名冠脉造影结果正常的患者,其余21名患者经4-12个月的随访无相关不适症状和心脏事件发生.G1中所有受检者的心肌灌注影像均正常.第2组(G2),n=14,EXHLR<2,其中有8人经冠状动脉造影证实有明显的冠脉狭窄,其余6名患者中有4人在随访过程中有一次以上心绞痛发作并伴有典型心电图(ECG)改变.两组受检者不同时间的HLR均存在显著差异(P=0.000).G2中有9名患者显像结果正常,其中4人经冠脉造影证实为冠心病患者(狭窄程度50%-70%).其余5人显像结果均为可逆或不可逆性灌注缺损图.冠心病患者行99TcmN-NOET运动-延迟心肌显像时,心肺比值明显高于非冠心病患者,即使心肌显像分布无缺损,但肺摄取99TcmN-NOET显著增高.  相似文献   

10.
谢昌辉  马志海  李秀江  邓少杰 《核技术》2005,28(11):863-866
将40只家兔施行断肢再植术后20min随机分为A(25只)、B(15只)两组,A组伤口局部冷敷(<5°C)、B组热敷(40—45°C)10min,C组(5只正常对照家兔)置于室温(20—25°C)。所有家兔耳缘静脉注射Na99TcmO474MBq后行动态和静态显像,计算并分析再植部分和正常肢对应部分的放射性摄取比值(T/NT)。手术探查再植肢是否并发血管危象(VC)。根据术肢远端放射性聚集程度将显像结果分为Ο、Ⅰ、Ⅱ三级,结果显示:T/NT分别为0.142±0.061、0.472±0.055、0.843±0.184(t=7.23、13.65、2.71,P<0.01),将Ο级(T/NT<0.25)作为VC的定性和半定量诊断标准。手术探查证实A、B、C三组分别有25只、3只、0只家兔并发VC,局部冷敷制备VC动物模型的成功率100%;Na99TcmO4示踪显像(Na99TcmO4traceimaging,TTI)诊断VC的灵敏度(96.4%),明显高于临床常规方法(Clinicalroutinemethod,CRM)(39.3%)(χ2=20.9,P<0.01)。表明TTI较CRM更能直观而准确地反映再植末端的血供状况,能早期无创地监测断肢(指)再植术后VC的发生。  相似文献   

11.
为消除HI 13串列加速器由于升级改造可能引起的分析磁铁常数K的变化所带来的影响,利用共振核反应12C(p,α0)9B对常数K进行了重新刻度。重新刻度的K为(43.5282±0.0007)eV•Hz-2,较原始刻度值降低了0.652%,能量分辨为ΔE/E=(1.56±0.25)×10-4,基本无变化。  相似文献   

12.
Stable combustion in an afterburner can help increase the thrust of the engine in a short time, thereby improving the maneuverability of a fighter. To improve the ignition performance of an afterburner, a twin-duct ignition platform was designed to study the performance of a gliding arc plasma igniter in close-to-real afterburner conditions. The research was carried out by a combination of experiments and simulations. The working environment of the igniter was explored through a numerical simulation. The results showed that the airflow ejected from the radiating holes formed a swirling sheath, which increased the anti-interference ability of the airflow jet. The influence of the pressure difference between the inlet and outlet of the igniter (Δp), the flow rate outside the igniter outlet (W2), and the installation angle (α) on the single-cycle discharge energy (E) as well as the maximum arc length (L) were studied through experiments. Three stages were identified: the airflow breakdown stage, the arc evolution stage, and the arc fracture stage. E and L increased by 107.3% and 366.2%, respectively, with Δp increasing from 10 to 70 Torr. The relationship between L and Δp obtained by data fitting is L = 3 − 2.47/(1 + (Δp/25)4). The relationship of L at different α is Lα=0° > (Lα=45° and Lα=135°) > Lα=180° > Lα=90°. E and L decrease by 18.2% and 37.3%, respectively, when Δp = 45 Torr and W2 is increased from 0 to 250 l min−1.  相似文献   

13.
平衡法放射性核素心血管造影局部室壁运动的定性分析有助于对室壁运动异常作出评价。但由于评价结果主要由观察者依据心室舒张末期及收缩末期这二个时相的边界叠加影象来判断,因而主观因素不可避免。特别是对冠心病例,其室壁运动“正常”与“运动低下”之间的鉴别尤为困难,对室间隔的活动也往往难于估价。为此,本文研究了局部室壁运动的计算 平衡法放射性核素心血管造影局部室壁运动的定性分析有助于对室壁运动异常作出评价。但由于评价结果主要由观察者依据心室舒张末期及收缩末期这二个时相的边界叠加影象来判断,因而主观因素不可避免。特别是对冠心病例,其室壁运动“正常”与“运动低下”之间的鉴别尤为困难,对室间隔的活动也往往难于估价。为此,本文研究了局部室壁运动的计算  相似文献   

14.
采用分光光度法研究HNO2与N,N-乙基,羟乙基羟胺(EHEH)在高氯酸介质中的反应动力学,得到了反应动力学速率方程。研究结果表明:当温度为25℃、离子强度为1.0mol/L时,反应速率常数k=3.43(mol/L)-0.93•min-1,反应活化能Ea=(50.0±2.5)kJ/mol;升高温度、提高EHEH和高氯酸浓度,反应速率加快。  相似文献   

15.
为研究铀矿工染色体畸变及外周血象的变化,采集236名从事铀矿工作人员(矿工组)和64名无射线接触健康人员(对照组)的外周血,采用血常规检测及微量全血培养法进行淋巴细胞染色体畸变分析。结果发现:矿工组染色体型畸变率0.16%、染色单体型畸变率0.20%、总畸变率0.36%、畸变细胞率0.30%,明显高于对照组(0.02%、0.06%、0.08%、0.08%),差异有统计学意义(u=2.80,p<0.01;u=2.40,p<0.05;u=3.60,p<0.01;χ2=9.88,p<0.01)。外周血象比较,矿工组外周血象均在正常范围内,但白细胞计数(WBC)、红细胞计数(RBC)、血小板(PLT)均低于对照组,与对照组比较,PLT差异有统计学意义(p<0.01),WBC、RBC无统计学意义(P>0.05);矿工组血象异常发生率与对照组比较,RBC差异有统计学意义(p<0.05),WBC、PLT差异无统计学意义(p>0.05)。由此可见,铀矿工人长期接触电离辐射后引起染色体畸变率升高,在放射职业健康检查中染色体畸变检查较一般血液学指标敏感且"预警"作用明显。  相似文献   

16.
对Ed=20keV的氘束入射到D-Ti靶上由2H(d,γ)4He反应产生的γ射线及由2H(d,p)3H反应产生的质子进行测量,得到分支比Γγ/Γp为(1.06±0.42)×10-72H(d,γ)4He反应截面σ的上限值为(2.9±1.2)×10-39m2。  相似文献   

17.
The vaporization of Li2TiO3(s) has been investigated by the mass spectrometric Knudsen effusion method. Partial pressures of Li(g), LiO(g), Li2O(g), Li3O(g) and O2(g) over Li2TiO3(s) have been obtained in the temperature range 1180–1628 K. When the vaporization of Li2TiO3(s) proceeds, the content of Li2O in the Li2TiO3(s) sample decreases. The phase of the sample is a disordered Li2TiO3 solid solution above 1486 K. The enthalpies of formation and the atomization energies for LiO(g) and Li3O(g) have been evaluated from the partial pressures to be ΔHof0(LiO, g) = 65.4 ± 17.4 kJ/mol, ΔHof0(Li3O, g) = − 207.5 ± 56.6 kJ/mol, Do0(LiO) = 340.5 ± 17.4 kJ/mol and Do0(Li3O) = 931.6 ± 56.6 kJ/mol, respectively.  相似文献   

18.
用反符合方法测量131I和133Ba的比活度   总被引:1,自引:1,他引:0  
131I是核医学应用中较为重要的核素之一;133Ba是1种电子俘获核素,对HPGeγ谱仪能量刻度和效率校准具有重要意义。利用4πβ(PPC)-γ(HPGe)反符合测量装置对上述两种核素的活度进行了反符合测量方法研究,所得到的比活度测量结果分别为1794.8(1±0.6%)kBq•g-1(k=1)和502.8•(1±0.6%)kBq•g-1(k=1),与归一到相同参考时刻4πβ(PC)-γ(NaI(Tl))符合效率外推法的测量结果1797.6(1±0.5%)kBq•g-1(k=1)和504.9(1±0.6%)kBq•g-1(k=1)均在不确定度范围内一致。  相似文献   

19.
本文将氢化钛镍合金材料应用于强流长脉冲(200 A/270 μs)真空弧放电实验中,该材料能在强流长脉冲真空弧放电产生的高温条件下保持较好的稳定性。使用飞行时间谱仪获得了氢化钛镍合金阴极真空弧放电产生的离子电荷态分布和离子成分。结果表明:Tin+和Nin+电荷态为1+、2+和3+,在放电过程的早期(0~30 μs),H+成分随时间逐渐增加,在30 μs时达到最大比例57%,而Tin+和Nin+(n=1,2,3)离子成分随时间逐渐减少,在30 μs时达到最小比例43%;在放电过程的后期(30~270 μs),H+成分迅速下降且在75 μs后保持在总离子流的12%左右直至放电结束,Tin+和Nin+(n=1,2,3)含量随时间逐步增加,且在75 μs后保持在总离子流的88%左右直至放电结束。  相似文献   

20.
42只双侧前胸壁荷瘤的VX2兔模型(共计84个肿瘤)随机分为治疗组(n=32)和对照组(n=10).治疗组静脉给予4mg/kg顺铂前(Pre-therapy)和给药后95-100min(Day 0)、Day 1、Day7、Day 14行PET/CT显像;对照组不给化疗药物,其余与实验组相同.取葡萄糖摄取最大值(SUVmax)进行分析,CT测量肿瘤大小.按肿瘤体积分组,Day 7时治疗组肿瘤体积增长>1倍则为不敏感,反之为敏感.结果显示:(1)Day 0敏感组SUVmax减低率为(-48.96±12.27)%,而不敏感组和对照组为(21.26±18.26)%和(7.16±13.47)%,三组SUVmax变化有显著差异(P<0.05).(2)Pre-therapy、Day 0、Day 1、Day 14两组肿瘤体积无显著性差异(P>0.05),但Day 7敏感组肿瘤体积小于不敏感组及对照组,差异有显著性(P<0.05).(3)Day 7、Day 14敏感组肿瘤坏死率大于不敏感组及对照组,差异有显著性(P<0.05).(4)HE染色观察不同时间点切除的肿瘤标本发现:Day 7、Day 14时敏感组肿瘤细胞数少而炎性和坏死细胞数增加.表明根据化疗药物给予后FDG减低程度,18F-FDG PET/CT能在体、早期、灵敏检出肿瘤对化疗药物的敏感性.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号